100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Driver Operator Mobile Water Supply Complete Questions With Solutions (2024) $12.99   Add to cart

Exam (elaborations)

Driver Operator Mobile Water Supply Complete Questions With Solutions (2024)

 7 views  0 purchase
  • Course
  • Mobile water supply
  • Institution
  • Mobile Water Supply

Driver Operator Mobile Water Supply Complete Questions With Solutions (2024)

Preview 2 out of 10  pages

  • August 27, 2024
  • 10
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • daily inspection
  • Mobile water supply
  • Mobile water supply
avatar-seller
ElevatedExcellence
Driver Operator Mobile Water Supply
Complete Questions With Solutions
(2024)
Identify FIVE requirements for a MWS apparatus that can be found in NFPA 1901
CORRECT ANSWERS 1. An MWS apparatus equipped with a fire pump must have a
tank to pump line at least two inches in diameter and be capable of supplying the pump
with 500 GPM until at least 80% of the tank is emptied.

2. An MWS apparatus must be equipped with at least one external fill connection
connected into the tank that allows the tank to be filled at a minimum rate of 1000 GPM.

3. The external fill connection should be equipped with a valve, strainer, and a 30
degree elbow.

4.Valves that are three inches or larger must be of the slow closing design.

5. An MWS apparatus must have at least three large tank discharges capable of
discharging 90% of the tank volume at an average of 1000 GPM.

When Checking the left front or right front side of the fire apparatus, don't forget to
inspect the: CORRECT ANSWERS saddle tanks

Daily inspection CORRECT ANSWERS Ensure auxiliary fuel tank is full

Operate pump primer

Inspect auxiliary winterization system.

Weekly Inspection CORRECT ANSWERS Clean intake strainers

Pre-service pump certification test are conducted by: CORRECT ANSWERS An
independent testing agency

When using a static body of water as your water source during fire apparatus service
testing, the water surface must not be more than___ feet above the centerline of the
pump intake and the water must be at least _____ feet deep. CORRECT ANSWERS 10
Feet above

4 Feet deep

, If the engine speed check proves the MWS apparatus is running at a different speed
than what which it was originally rated, you need to? CORRECT ANSWERS Stop the
testing until the problem is corrected.

A year has passed and its time conduct the annual vacuum test on your departments
MWS apparatus. You're following the procedures for conducting the vacuum test and
you've already checked for and removed foreign matter from the hard suction hose. The
next step to perform while conducting the vacuum test is to: CORRECT ANSWERS
Connect 20 Feet of the hard suction hose to the pump intake connection.

When conducting a priming device test and using a pump of less than 1500 GPM, the
priming device should be able to create the necessary vacuum in ____ seconds to lift
water 10 feet through 20 feet of hard suction hose. CORRECT ANSWERS 30 seconds

Place the steps for conducting a pumping test in the correct order. CORRECT
ANSWERS 1. Gradually speed up the pump until the net pump discharge pressure is
150 PSI

2. Use a pitot tube or a flow meter to check the flow of water at the nozzle.

3.Record six different readings at 5-minute intervals for a total of 20 minutes.

4. Set the net pump discharge pressure to 200 PSI.

5. Set the net pump discharge pressure to 250 PSI.

Pressure Control Test CORRECT ANSWERS 1. Engage the pump and set it to the
pump capacity.

2. Set the pressure control device.

3. Close the discharge valves.

4. Note the pump discharge

The three parts of the pressure control test require you to close the flowing valves one
at a time: CORRECT ANSWERS In no less than 3 seconds and no more than 10
seconds

The gauge and flow meter readings with actual pitot tube readings. The two readings
should differ by no more than: CORRECT ANSWERS 10%

The tank to pump flow rate test measures whether the piping between an apparatus
water tank and fire pump meets the minimum flow standards of: CORRECT ANSWERS
NFPA 1901

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller ElevatedExcellence. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $12.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

64438 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling