What must be done before removing an oil tank and where is it obtained? -
ANSWER>>permit, from the fire department
All oil tanks over ________________ must have an open air vent pipe.
Minimum pipe size of _________...
Mass oil burner exam questions with correct answers 100%
Already Graded A
What must be done before removing an oil tank and where is it obtained? -
ANSWER>>permit, from the fire department
All oil tanks over ________________ must have an open air vent pipe.
Minimum pipe size of ___________. The fill pipe cannot exceed the size of
vent pipe. Both must terminate _______________? - ANSWER>>10 gallons, 1
1/4", outside of building
No more than how many gallon oil tank (1) can be exposed in a building? -
ANSWER>>660 gallons
Exposed tanks ( more than 1) in a building cannot be more than how many
gallons? - ANSWER>>1320
What must be done with any unused openings on an oil tank? -
ANSWER>>Made vapor tight
What cannot be used for fill and vent piping? - ANSWER>>Solder copper
tubing and fittings, or plastic piping.
All oil tanks with fill and vent pipes must have what type of gauging
device? - ANSWER>>Visual or audible
The maximum total capacity of all the tanks located above the lowest level
of a building cannot exceed how many gallons? - ANSWER>>60
, The maximum total capacity of all the tanks located above the lowest level
of a building has an exception what is it? - ANSWER>>A tank on slab
adjacent to first floor
Vent pipe mjst terminate at least how many feet above grade? -
ANSWER>>3 feet
Vent pipe must terminate ____ feet vertically and _______ horizontally from
any building opening. - ANSWER>>Two, two
What mjst vent pipe have on the terminate outside of building? -
ANSWER>>water tight cap
Fill and vent pipes are slopped in which direction? - ANSWER>>towards
tank
re fixed sash windows considered a building opening to apply to fill and
vent piping? - ANSWER>>No
What is the definition of confined space? - ANSWER>>A space supplying
air for combustion whose volume is less than 50 cubic feet per 1000 btu
per hour input of all appliances in the space
What is the maximum voltage used for oil burner circuits? -
ANSWER>>150v
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller winniewaweru. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $13.99. You're not tied to anything after your purchase.