Where artificial light is utilized for required illumination, it shall provide an
__- __- __- __- __- __- __- __- __- __- __- __-


average illumination of ------foot-candles over the area of the room at a
__- __- __- __- __- __- __- __- __- __- __- __-


height of -----inches above the floor level.
__- __- 10 __- __- __- __- __-__- __-




30


1205.3 artificial light
__- __-




A smoke protected assembly seating area with a roof shall have the
__- __- __- __- __- __- __- __- __- __- __- __-


lowest portion of the roof deck not less than ____ feet above the highest
__- __- __- __- __- __- __- __- __- __- __- __- __- __-


aisle or aisle accessway.
__- __- 15 __- __-__- __-




See the exception that allows for a reduction in roof height for outdoor
__- __- __- __- __- __- __- __- __- __- __- __- __-


stadiums.


1029.6.2.2 Roof height __- __-




A facing attached to a wall for the purpose of providing ornamentation,
__- __- __- __- __- __- __- __- __- __- __- __-


protection or insulation, but not counted as adding strength to the wall.
__- __- __- __- __- __- __- __- __- __- __- __-__-


Veneer
__-




202 Definition
__-

,Smoke alarms shall not be placed within ----feet horizontally from the door
__- __- __- __- __- __- __- __- __- __- __- __-


or opening of a bathroom that contains a bathtub or shower.
__- __- __- __- 3 __- __- __- __- __- __- __-__- __-




907.2.11.4 Installation near bathrooms __- __- __-




Not more than -------percent of the ceiling area of a means of egress can
__- __- __- __- __- __- __- __- __- __- __- __- __- __-


be reduced in required height by protruding objects.
__- __- __-50 __- __- __- __- __-__- __-




1003.3.1 Headroom __-




Where natural light is utilized for illumination purposes, the minimum net
__- __- __- __- __- __- __- __- __- __- __-


glazed area shall not be less than -------percent of the floor area of the
__- __- __- __- __- __- __- __- __- __- __- __- __- __-


room served. 8%
__- __-__- __-




1205.2 Natural Light __- __-




Facilities for more than five but not more than 16 occupants, excluding
__- __- __- __- __- __- __- __- __- __- __- __-


staff, who reside on a 24-hour basis in a residential environment and
__- __- __- __- __- __- __- __- __- __- __- __-


receive custodial care are Group -----occupancies.
__- R-4 __- __- __- __- __-__- __-




The uses and conditions in this group are consistent with those of group I-
__- __- __- __- __- __- __- __- __- __- __- __- __-


1 occupancies
__-




310.6 Residential Group R-4
__- __- __-




Smoke Compartment __- A space within a building enclosed by smoke __-__- __- __- __- __- __- __- __- __- __-


barriers on all sides, including the top and bottom.
__- __- __- __- __- __- __- __-

,702.0,202


Guards shall be located along open-sided walking surfaces, mezzanines,
__- __- __- __- __- __- __- __- __-


equipment platforms, stairs, ramps and landings that are located more
__- __- __- __- __- __- __- __- __- __-


than ---------inches above the floor or grade below.
__- 30 inches __- __- __- __- __- __- __-__- __- __-




As a general rule, required guards shall be a minimum of 42 inches high.
__- __- __- __- __- __- __- __- __- __- __- __- __-




1015.2 Where Required
__- __-




Doors in the fully open position shall not reduce the required dimension
__- __- __- __- __- __- __- __- __- __- __- __-


by more than ------inches.
__- __- 7 inches __- __-__- __- __-




1010.106 Landings at doors __- __- __-




The required fire resistance of a building element shall be permitted to be
__- __- __- __- __- __- __- __- __- __- __- __- __-



established by -------in accordance with section 722.
__- __- Calculations __- __- __- __- __-__- __-




Review the 6 alternative methods for determining fire resistance.
__- __- __- __- __- __- __- __-




703.3 Alternative methods for determining fire resistance, item 3
__- __- __- __- __- __- __- __-




703.3 Alternative methods for determining fire resistance:
__- __- __- __- __- __- __-__- __- 1) Fire-
__-


resistance design documented in approved sources
__- __- __- __- __-

, 2) Prescriptive design of fire-resistance-rated building elements, components
__- __- __- __- __- __- __- __-


or assemblies as prescribed in section 721
__- __- __- __- __- __-




3) Calculations in accordance with section 722
__- __- __- __- __- __-




4) Engineering analysis based on a comparison of building element,
__- __- __- __- __- __- __- __- __- __-


component or assemblies design having fire-resistance rating as determined
__- __- __- __- __- __- __- __- __-


by the test procedure set forth in ASTM E119 or UL 263
__- __- __- __- __- __- __- __- __- __- __-




5) Alternative protection methods as allowed by section 104.11
__- __- __- __- __- __- __- __-




6) Fire-resistance design certified by an approved agency
__- __- __- __- __- __- __-




Where two or more exits are required, not more than ------of the total
__- __- __- __- __- __- __- __- __- __- __- __- __-



number of exits or total exits width shall be horizontal exits.
__- __- __- one-half
__- __- __- __- __- __- __- __-__- __- __-


or 50%
__-




1026.1 Horizontal exits
__- __-




Fire walls shall be continuous from exterior wall to exterior wall and shall
__- __- __- __- __- __- __- __- __- __- __- __- __-


extend at least ____ inches beyond the exterior surface of exterior walls.
__- __- __- __- __- __- __- __- __- __- __- __-__-


18 inches
__- __-




Review the 3 exceptions that permit a fire wall to terminate at the
__- __- __- __- __- __- __- __- __- __- __- __- __-


exterior wall. __-

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller AcademiaExpert. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $15.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

67866 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$15.49
  • (0)
  Add to cart