100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

reg4 fire pump practice questions and answers (100% pass)

Beoordeling
-
Verkocht
-
Pagina's
6
Cijfer
A+
Geüpload op
29-08-2024
Geschreven in
2024/2025

reg4 fire pump practice questions and answers (100% pass) batteries attempt to start cycle test - Answer️️ -3min test , 6 consecutive cycles of 15sec of cranking and 15 sec of rest pump and jockey Sensing line shall have no - Answer️️ -shut off valve pump and jockey Sensing line shall have 2 3/32nd check valves or unions at least how far apart? - Answer️️ -5feet pump and jockey Sensing line have small orfice checks for what purpose? - Answer️️ -dampening a pressure gauge having a dial not less than ________ in. in diameter and with a nominal size of _________ shall be connected near the discharge casting and the suction piping - Answer️️ -3.5 in dial and .25 nominal or 1/4in the discharge gauge shall indicate pressure to at least ________ the rated working pressure of the pump but not less than ________ psi - Answer️️ - twice / 200 the suction gauge shall have a pressure range of ________ the rated max suction pressure of the pump - Answer️️ -2 times ©SOPHIABENNETT@ Saturday, August 24, 2024 8:52 AM 2 where the minimum pump suction pressure is below ______ psi under any flow condition, the suction gauge shall be a ______ _______ ______ ________ - Answer️️ -20/ compound pressure vacuum gauge if the pump is equipped with a bypass the piping shall be what size - Answer️️ -at least as large as the pipe size required for the discharge pipe as specified in table 4.27 no control valve other than a listed os&y gate valve shall be installed in the suction pipe within _____ft of the _______ _______ - Answer️️ -50 / suction flange maximum number of fire pumps in series - Answer️️ -three if the pump is equipped with a pressure relief valve no _______ valve is allowed - Answer️️ -shutoff how many test header hose valves for a 2000 gpm pump - Answer️️ -six where pumps are in series a butterfly valve shall ______ installed between pumps - Answer️️ -not elbows and tees with a centerline plane parallel to a horizontal split-case pump shaft shall not be permitted in the suction piping unless - Answer️️ -the distance between the pump suction flange and elbow or tee flange is greater the 10 times the suction pipe diameter each pump supplying suction pressure to another pump shall be arranged to start within? - Answer️️ -10 sec before the pump it supplies ©SOPHIABENNETT@ Saturday, August 24, 2024 8:52 AM 3 if water requirements call for more than one pump to operate at a time , the pumps shall start at intervals of ? - Answer️️ -5 to 10 seconds where the suction pipe and pump suction flange are not of the same size ,they shall be connected with a ? - Answer️️ -eccentric tappered reducer or increaser installed in such a way as to avoid air pockets where the max flow available from a water supply cannot provide a flow of 150 percent of the rated flow for the pump but can provide the greater of 100 percent of rated flow or max flow demand of fire system the water supply shall be deemed? - Answer️️ -adequate. in th

Meer zien Lees minder
Instelling
Fire Pump
Vak
Fire Pump

Voorbeeld van de inhoud

©SOPHIABENNETT@2024-2025 Saturday, August 24, 2024 8:52 AM



reg4 fire pump practice questions and
answers (100% pass)

batteries attempt to start cycle test - Answer✔️✔️-3min test , 6 consecutive
cycles of 15sec of cranking and 15 sec of rest

pump and jockey Sensing line shall have no - Answer✔️✔️-shut off valve

pump and jockey Sensing line shall have 2 3/32nd check valves or unions
at least how far apart? - Answer✔️✔️-5feet

pump and jockey Sensing line have small orfice checks for what purpose? -
Answer✔️✔️-dampening

a pressure gauge having a dial not less than ________ in. in diameter and
with a nominal size of _________ shall be connected near the discharge
casting and the suction piping - Answer✔️✔️-3.5 in dial and .25 nominal or
1/4in

the discharge gauge shall indicate pressure to at least ________ the rated
working pressure of the pump but not less than ________ psi - Answer✔️✔️-
twice / 200

the suction gauge shall have a pressure range of ________ the rated max
suction pressure of the pump - Answer✔️✔️-2 times




1

, ©SOPHIABENNETT@2024-2025 Saturday, August 24, 2024 8:52 AM


where the minimum pump suction pressure is below ______ psi under any
flow condition, the suction gauge shall be a ______ _______ ______
________ - Answer✔️✔️-20/ compound pressure vacuum gauge

if the pump is equipped with a bypass the piping shall be what size -
Answer✔️✔️-at least as large as the pipe size required for the discharge pipe
as specified in table 4.27

no control valve other than a listed os&y gate valve shall be installed in the
suction pipe within _____ft of the _______ _______ - Answer✔️✔️-50 /
suction flange

maximum number of fire pumps in series - Answer✔️✔️-three

if the pump is equipped with a pressure relief valve no _______ valve is
allowed - Answer✔️✔️-shutoff

how many test header hose valves for a 2000 gpm pump - Answer✔️✔️-six

where pumps are in series a butterfly valve shall ______ installed between
pumps - Answer✔️✔️-not

elbows and tees with a centerline plane parallel to a horizontal split-case
pump shaft shall not be permitted in the suction piping unless -
Answer✔️✔️-the distance between the pump suction flange and elbow or tee
flange is greater the 10 times the suction pipe diameter

each pump supplying suction pressure to another pump shall be arranged
to start within? - Answer✔️✔️-10 sec before the pump it supplies


2

Geschreven voor

Instelling
Fire Pump
Vak
Fire Pump

Documentinformatie

Geüpload op
29 augustus 2024
Aantal pagina's
6
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
SophiaBennett Howard Community College
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
140
Lid sinds
1 jaar
Aantal volgers
5
Documenten
9099
Laatst verkocht
5 dagen geleden
EXAM GAME-CHANGER

Exam Questions and Answers Section : Study Like a Pro, Study Smart, Study with Sophia.

3.7

26 beoordelingen

5
10
4
5
3
7
2
1
1
3

Populaire documenten

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen