100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten
logo-home
INDUSTRIAL ELECTRICIAN V5 (NCCER) EXAM QUESTIONS WITH COMPLETE SOLUTIONS $12.49
In winkelwagen

Tentamen (uitwerkingen)

INDUSTRIAL ELECTRICIAN V5 (NCCER) EXAM QUESTIONS WITH COMPLETE SOLUTIONS

 0 keer verkocht
  • Vak
  • NCCER Electrical
  • Instelling
  • NCCER Electrical

The PEAK voltage in a normal 120/208 VAC system is: - Answer-170 V. What is a fish tape used for? - Answer-Pulling wire or rope through conduit As the ambient temperature surrounding a self-regulating heating cable gets warmer, the - Answer-Increases. Rubber personnel protective insulating...

[Meer zien]

Voorbeeld 2 van de 7  pagina's

  • 4 september 2024
  • 7
  • 2024/2025
  • Tentamen (uitwerkingen)
  • Vragen en antwoorden
  • NCCER Electrical
  • NCCER Electrical
avatar-seller
lectknancy
INDUSTRIAL ELECTRICIAN V5 (NCCER)
EXAM QUESTIONS WITH COMPLETE
SOLUTIONS
The PEAK voltage in a normal 120/208 VAC system is: - Answer-170 V.

What is a fish tape used for? - Answer-Pulling wire or rope through conduit

As the ambient temperature surrounding a self-regulating heating cable gets warmer,
the - Answer-Increases.

Rubber personnel protective insulating equipment must be marked with the appropriate
voltage rating and - Answer-Expiration date.

Which plan indicates the location of structures and equipment on a property? - Answer-
Site

THWN conductors have an outer jacket made of: - Answer-Nylon

Which of the following is the classified location where combustible vapors are always
present? - Answer-Class I Div I

When installing more than one ground rod, what is the MINIMUM spacing between rods
- Answer-10 ft.

The length of bare copper conductor in a ground ring MUST be buried no less than 2.5'
below grade and - Answer-10 ft.

What is the purpose of sealing cable ends that are in storage? - Answer-To keep
moisture from entering in.

What is the multiplier from calculating a 45-degree offset when conduit is being bent? -
Answer-1.414

Where raceways connect an enclosure required to be dust/ ignition proof to an
enclosure in an UNCLASSIFIED location - Answer-Not required.

Which typed of rigid metal conduit would be most appropriate for a corrosive
environment? - Answer-Stainless steel

A material with poor electrical conducting properties is a good - Answer-Insulator

, Insulation on the barrel of crimp connectors for wires sized 22-16 AWG are typically
colored. - Answer-Red

A protective device for limiting voltage spikes by discharging or bypassing surge current
is called a - Answer-Surge protector.

A Type LB conduit body has the cover on - Answer-The back.

All of the following are common service voltage in the United States EXCEPT - Answer-
372/575 three-phase, four-wire.

Why should the test leads of a "megger" NEVER be touched by anyone when in use? -
Answer-It could result in an electrical shock.

What is the purpose of lockout/ tagout? - Answer-Prevent operation.

With a row of 3-4" conduits and second row of 3-2" and 2-1" conduits for a angle pull
box what is the MINIMUM distance between the pull box? - Answer-32"

How should heat-shrink insulators be installed? - Answer-The insulator should be
slipped over the connector and heat should be applied for a few seconds

A megohmmeter will be used to check a cable. The electrician MUST be sure that the
circuit is - Answer-De-energized and locked, tagged out, and tested.

In a typical 3 wire start/stop station, where will the incoming control voltage wire be
terminated? - Answer-Stop button normally closed

Exposed field-routed electrical conduit SHOULD be installed so that it - Answer-Is
plumb and level.

Which electrical values CANNOT be tested using a VOM(multimeter)? - Answer-Watts

Who is allowed to remove another electricians tag or lock from any valve, switch, or
piece of equipment without proper authorization? - Answer-No one.

What is the PRIMARY consideration in selecting the rope for a cable pull? - Answer-
Low stretch

A 1500 KVA three phase transformer has a secondary voltage of 480/277. What is the
secondary full load amperage? - Answer-5.42

What is the MINIMUM distance between raceway entries allowed in a pull box for angle
pills? - Answer-6x the largest trade size raceway

True power is measured in: - Answer-Watts

Dit zijn jouw voordelen als je samenvattingen koopt bij Stuvia:

Bewezen kwaliteit door reviews

Bewezen kwaliteit door reviews

Studenten hebben al meer dan 850.000 samenvattingen beoordeeld. Zo weet jij zeker dat je de beste keuze maakt!

In een paar klikken geregeld

In een paar klikken geregeld

Geen gedoe — betaal gewoon eenmalig met iDeal, Bancontact of creditcard en je bent klaar. Geen abonnement nodig.

Focus op de essentie

Focus op de essentie

Studenten maken samenvattingen voor studenten. Dat betekent: actuele inhoud waar jij écht wat aan hebt. Geen overbodige details!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper lectknancy. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor $12.49. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 64670 samenvattingen verkocht

Opgericht in 2010, al 15 jaar dé plek om samenvattingen te kopen

Start met verkopen
$12.49
  • (0)
In winkelwagen
Toegevoegd