100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
ICC Mechanical Exam Practice Questions Part 1 Questions and Answers 2024 $13.99   Add to cart

Exam (elaborations)

ICC Mechanical Exam Practice Questions Part 1 Questions and Answers 2024

 6 views  0 purchase
  • Institution
  • ICC

ICC Mechanical Exam Practice Questions Part 1

Preview 2 out of 6  pages

  • September 7, 2024
  • 6
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
All documents for this subject (245)
avatar-seller
julianah420
ICC Mechanical Exam Practice
Questions Part 1

Exhaust ducts under positive pressure, chimneys, and vents may not extend into or
pass through _________________. Exceptions ignored. - answer plenums and ducts

_____________________________________ systems are permitted to be backfilled
prior to inspection. - answer Ground-source heat pump loop

Air necessary for complete combustion of a fuel, including theoretical air and excess air.
- answer Combustion Air

Equipment and appliances installed at grade level must be supported on a level
concrete slab or other approved material extending not less than 3 inches above
adjoining grade or must be suspended not less than ____________ above adjoining
grade. Such support shall be in accordance with the manufacturer's installation
instructions. - answer6 inches

Air removed from a conditioned space and intended for reuse as supply air. - answer
Recirculated Air

For buildings containing dust, stock and refuse collectors and separators such systems
as centrifugal separators, bag filter systems and similar devices, those devices and
associated supports must be constructed of noncombustible materials and must be
located on _________________________ . Exceptions ignored. - answer the exterior of
the building or structure

An installer has an 80,000 Btu per hour input fan-assisted appliance that must be
installed using 10 feet of lateral connector attached to a 30-foot-high Type B vent. Two
90-degree elbows are needed for the installation. Can a single-wall metal vent
connector be used for this application? - answer No

On a liquid fuel oil system the outer ends of vent pipes must terminate in a
_______________________. - answer weatherproof vent cap or fitting or be provided
with a weatherproof hood

Ventilation must be provided in an approved manner in battery-charging areas for
powered industrial trucks and equipment _____________________. Exceptions
ignored. - answer to prevent a dangerous accumulation of vapor pressure

, The installation of fuel gas distribution piping and equipment, fuel gas- fired appliances
and fuel gas-fired appliance venting systems is regulated by the
____________________________________. - answer International Fuel Gas Code

2x12 nominal ceiling joists 12 feet long will need to be notched to accommodate an air
duct, if the notch is at the top of the joists and not in the center 1/3 of the joists. What is
the maximum allowable depth of the notches in inches? - answer1.875 inches

Ducts and air transfer openings are required to be protected with a minimum Class II,
_______________ smoke damper complying with the International Building Code. -
answer250 degrees

What is the minimum required clearance distance from combustibles for commercial
kitchen Type I hood installation? Exceptions Ignored. - answer18 inches

R-290 Refrigerant has what refrigerant classification. - answerA3

The minimum size of a supply line for a fuel oil system is
_______________ inside diameter nominal pipe or _________ OD tubing. - answer3/8-
inch, 3/8-inch

On a fuel oil system, a relief valve must be installed on the pump discharge line where a
valve is located __________________ the pump and the pump is capable of exceeding
the pressure limitations of the fuel oil system. - answer downstream of

An alternative material, design or method of construction may be approved where the
code official finds that the proposed design is satisfactory and complies with the intent
of the provisions of the code, and that the material, method or work offered is, for the
purpose intended, at least the equivalent of that prescribed in the code in
______________________________________________________________. - answer
quality, strength, effectiveness, fire resistance, durability and safety.

Solar thermal equipment exposed to vehicular traffic has to be installed not less than
_______________ above the finished floor. Exception: This section must not apply
where the equipment is protected from motor vehicle impact. - answer6 feet

Sub slab soil exhaust system ducts must extend through the roof and terminate at least
___________________ above the roof and at least 10 feet from any operable openings
or air intake. - answer6 inches

A passageway within a chimney or vent through which gaseous combustion products
pass. - answer flue

Air exhaust and intake openings that terminate outdoors must be protected with
corrosion- resistant screens, louvers or grilles. For intake openings in commercial

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller julianah420. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $13.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

80461 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$13.99
  • (0)
  Add to cart