100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Elevator Mechanic Test |Questions Solved 100% Correct| Verified Answers $13.49   Add to cart

Exam (elaborations)

Elevator Mechanic Test |Questions Solved 100% Correct| Verified Answers

 6 views  0 purchase
  • Course
  • Elevator mechanics
  • Institution
  • Elevator Mechanics

Elevator Mechanic Test |Questions Solved 100% Correct| Verified Answers

Preview 4 out of 35  pages

  • September 8, 2024
  • 35
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Elevator mechanics
  • Elevator mechanics
avatar-seller
KenAli
Elevator Mechanic Test |Questions Solved 100%
Correct| Verified Answers

In place of a sump pump, what else shall be provided on elevators equipped with
Firefighters' Emergency Operation
ASME A17.1-2004
2.2.2.5 - ANSWER Drain



On a Group IV elevator, how far shall a pit ladder extend no less than how many inches above
the sill of the access door
ASME A17.1-2004
2.2.4.2 - ANSWER 48 inches



Where pit mounted counterweight buffers are used, a counterweight guard is not required
when the bottom of the counterweight resting on its compressed buffer is how many inches
or more above the pit floor
ASME A17.1-2004

2.3.2.2
5.10.1.3.2 - ANSWER 84 inches



When an elevator rests on its fully compressed buffers or bumpers, there shall be a vertical
clearance of not less than how many inches between the pit floor and the lowest structural
or mechanical part, equipment, or device installed beneath the car platform

ASME A17.1-2004
2.4.1 - ANSWER 24 inches

,The minimum bottom runby of an un-counterweighted Group IV elevators shall not be less
than how many inches where the rated speed exceeds 30 fpm
ASME A17.1-2004
2.4.3 - ANSWER 6 inches


In no case shall the maximum bottom runby exceed how many inches for cars
ASME A17.1-2004
2.4.4 - ANSWER 24 inches



In no case shall the maximum bottom runby exceed how many inches for counterweights -
ANSWER 35 inches



The illumination measured at the landing sills of a Group IV elevator shall not be less than how
many foot candles
ASME A17.1-2004
2.11.10.2 - ANSWER 10 fc



What minimum size traveling cable conductor is used for elevator wiring other than
those supplying light and control equipment circuits.
14 gauge for lighting and control equipment - ANSWER 20 gauge



Phase I fire recall and a minimum of one floor operation of phase II fire service shall be tested
how often to ensure the system is in proper working order - ANSWER Monthly



Which of the following elevators require 5 yr load test to be performed: Group II, Group
III, Group IV
Title 8 Sec 3071 - ANSWER All of the above

,The tripping speed of an overspeed valve on a hydraulic elevator shall not be greater than
what percentage of the elevator operating speed in the down direction. Minimum is 110%
ASME A17.1-2004
2.19.4.7.5 - ANSWER 140 % Max


What is the maximum speed allowed for a spring buffer
ASME A17.1-2004
2.22.1.1.1 - ANSWER 200 fpm



When the quantity of hydraulic fluid loss can not be accounted for, which tests shall then be
performed ASME A17.1-2004
8.6.5.7
8.11.3.1.2(s)
Refer to: 8.11.3.2.1 - ANSWER Relief Valve and System Pressure test



Interlocks are required on which of these: Hydraulic elevators, Traction elevators,
wheelchair lifts - ANSWER All of the above



The force necessary to prevent closing of the elevator hoistway door on power
operated hoistway doors from rest shall not be more than?
ASME A17.1-2004
2.13.3.1.1 - ANSWER 30 pounds


The rated speed of a Group IV escalator shall not be more than?
ASME A17.1-2004
6.1.4.1 - ANSWER 100 fpm


How many shall be a minimum number of flat steps at the entrance and exit of each escalator

, ASME A17.1-2004
6.1.3.6.5 - ANSWER 2



An elevator shall be capable of maintaining emergency lighting at the required intensity for
a period of at least?
ASME A17.1-2004
2.14.7.1.3 - ANSWER 4 hours



What should be the minimum amount of clear path that shall be provided to all
components that require maintenance
ASME A17.1-2004
2.7.2.2.1 - ANSWER 18 inches


What shall be the minimum height of the access doors for Group IV elevator machine rooms
ASME A17.1-2004
2.7.3.4.1 - ANSWER 80 inches



What shall be the maximum width and height of access openings in Group III and IV
elevator hoistway enclosures where complete bodily entry is not necessary
ASME A17.1-2004
2.7.3.4.3 - ANSWER 24 inches



What shall be the minimum headroom of elevator machine rooms and machinery spaces
not located over the hoistway
ASME A17.1-2004
2.7.4.1 - ANSWER 84 inches



What is the safety conscious way to gain access to the elevator hoistway - ANSWER Using the in
car inspection switch and hoistway access key switch

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller KenAli. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $13.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

83637 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$13.49
  • (0)
  Add to cart