CETA Exam UNIT 1: Questions and Already passed Answers 2024 If a segregated radiopharma processing area is used to elute radionuclides generators - ANS it must have ISO Class 8 particle count non-viable particle count air quality Category 1 CSP - ANS A CSP assigned a BUD of 12 hours or le...

[Show more]

Preview 4 out of 44  pages

  • September 12, 2024
  • 44
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • CETa
  • CETa
avatar-seller
JPNAOMISTUVIA
M
AO
N
CETA Exam UNIT 1:
Questions and Already
JP


passed Answers 2024

,If a segregated radiopharma processing area is used to elute radionuclides generators -
ANS it must have ISO Class 8 particle count non-viable particle count air quality

Category 1 CSP - ANS A CSP assigned a BUD of 12 hours or less at controlled room
temperature or 24 hours or less refrigerated.

Category 2 CSP - ANS A CSP assigned in a BUD of greater than 12 hours room
temperature or greater than 24 hours refrigerated.

Immediate use CSP - ANS Administration begins within 4 hrs following the start of the
preparation. Must not involve more that 3 sterile products.




M
Glove Fingertip Sampling - ANS One plate per hand, TSA to support bacterial and
fungal growth, label each device, do not spray hands with IPA, Incubate 30-35 for 48 H
and 20-25 for 5 days, record CFU, Determine if CFU action level is exceeded by
counting the total number of CFU from both hands
AO
Media Fill Testing Procedure - ANS Simulate compounding activities if sterile to sterile
use soybean-casein digest media, if non sterile use commerically available nonsterile
soybean-casein digest powder to make a 3% non-sterile solution. Preparer at least 1
container as a positive control.

Once compounding simulations are completed perform gloved fingertip and thumb
sampling on each hand and surface sample of DCA inside the PEC. Take samples prior
N
to disinfecting.

Incubate 20-25 and 30-35 for a minimum of 7 days at each temperature.
JP

Failure is indicated by visible turbidity or other growth in one more containers on or
before 14 days.

Action Level for Gloved fingertip and thumb sampling - ANS After Garbing greater
than 0 CFU
After media-fill testing greater than 3 CFU

Action levels based on total CFU count from both hands

Compounder - ongoing training and competency - ANS Training and Competency in
compounding sterile principles - at least every 12 months

,Garbing Competency - Category 1 and 2 at least every 6 months, Category 3 every
months
Media Fill with Post GFT and Surface sampling - Category 1 and 2 at least every 6
months, Category 3 at least every 3 months

Designated Persons - ongoing training and competency - ANS Training and
Competency in compounding sterile principles - at least every 12 months unless
compounding
Garbing Competency - At least every 12 months unless compounding
Media Fill with Post GFT and Surface sampling -at least every 12 months unless
compounding




M
Personnel who restock or clean and disinfect the sterile compounding area- ongoing
training and competency - ANS Defined by facilities SOP

Handwashing procedures - ANS Clean under fingernails under warm running water
AO
using nail cleaner

Wash hands and forearms up to elbows for 30 s.

Dry hands and forearms up to elbows completely with low-lint disposable towels.

Apply an alcohol-based hand rub to dry skin
N
Apply product to one hand and rub hands together

Allow hands to dry before donning sterile gloves
JP

Minimum Garb requirements in category 2 and 3 - ANS Low Lint garment with sleves

Low Lint shoe covers

Low Lint cover for head and facial hair

Low Lint face mask

Sterile powder free gloves

If using a RABS disposable gloves should be worn inside the RABS sleeves.

, Additional garbing requirements for category 3 - ANS No exposed skin in the buffer
room (face/neck)

All lo-lint outer garb must be sterile, including use of over gauntlet sleeves in the RABS

Disposable garbing items must not be reused, laundered garb must not be reused
without being laundered and re-sterilized with a validated cycle

Facilities SOPs must describe procedures for using goggles, respirators, and other
reusable equipment




M
ISO 7 Classification - ANS 352,000 particle per cubic meter. Limits measured at
greater than 0.5 micrometers under dynamic operating conditions

ISO 5 Classification - ANS 3,520 particle count per cubic meter. Limits measured at
greater than 0.5 micrometers under dynamic conditions
AO
ISO 8 Classification - ANS 3,520,000 particle count per cubic meter. Limits measured
at greater than 0.5 micrometers under dynamic conditions

Design Requirements to maintain air quality <USP 797> - ANS Anterooms providing
access to positive-pressure buffer room must meet at least ISO Class 8

Anterooms providing access to negative-pressure buffer rooms must meet at least an
N
ISO Class 7.

A buffer room must meet at least ISO Class 7 air quality. Activities in the buffer room
must be controlled to minimize any effect on air quality in the are where CSP are
JP

prepared

Category 1, Category 2, and Category 3 CSPs must be compounded in an ISO Class 5
or better PEC. If compounding only Category 1 CSP, the PEC may be placed in a
Segregated Compounding Area

What temperature and humidity level does the cleanroom suite need to be maintained?
- ANS The cleanroom suite should be maintained at a temperature of 20 degrees or
cooler and a relative humidity of 60% or below to minimize the risk of microbial
proliferation and provide comfortable conditions for compounding personnel attired in
required garb.

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller JPNAOMISTUVIA. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $11.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

79271 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$11.99
  • (0)
  Add to cart