HVAC: EPA 608 Certification Study Guide with Complete Solutions Are there drop-in replacements for R-12 systems? Why or why not? - Answer️️ -No because the new refrigerants are incompatible with the oils and lubricants used in R-12 systems. What type of oil is used in R-134a and what oils ...

[Show more]

Preview 2 out of 14  pages

  • September 15, 2024
  • 14
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • EPA 608
  • EPA 608
avatar-seller
SophiaBennett
©SOPHIABENNETT
EXAM_SOLUTIONS GUARANTEED SUCCESS 2024/2025 ACADEMIC YEAR




©SOPHIABENNETT 9/2/24 2024/2025

, ©SOPHIABENNETT EXAM SOLUTIONS_2024/2025 Monday, September 2, 2024 12:59 PM



HVAC: EPA 608 Certification Study
Guide with Complete Solutions


Are there drop-in replacements for R-12 systems? Why or why not? - Answer✔️✔️-No

because the new refrigerants are incompatible with the oils and lubricants used in R-12

systems.


What type of oil is used in R-134a and what oils will it mix with? - Answer✔️✔️-Ester

based oils and they do not mix with other oils

What type of lubricant is used with HCFCs? - Answer✔️✔️-Alkylbenzene lubricant

What is difference b/w ternary blend a azeotropic blend? - Answer✔️✔️-Ternary blends

are three-part mixtures whereas azeotropic blends are blends of two or more

compounds that act like a single compound.

What is the trait of a hygroscopic lubricant? - Answer✔️✔️-It absorbs (takes on) moisture

What is temperature glide and what type of blend won't have it? - Answer✔️✔️-Temp.

blend is the difference between the dew point and the bubble point

Dew Point - Answer✔️✔️-Occurs when saturation temp in evaporator causes refrigerant

to change from liquid to vapor

Bubble Point - Answer✔️✔️-Occurs when saturation temp in condenser changes

refrigerant from vapor to liquid




Page | 1

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller SophiaBennett. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $9.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

72349 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$9.99
  • (0)
  Add to cart