You identify a PFO on an echo and the cardiologist asks you to calculate the LAP. How will you perform this calculation? -:- Measure the peak velocity across the PFO, calculate the peak pressure gradient across the defect and add the RAP. The mitral deceleration time is 300msec. What is the ...

[Show more]

Preview 4 out of 126  pages

  • September 17, 2024
  • 126
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • ECHO URR
  • ECHO URR
avatar-seller
TestTrackers
2024 /2025 | © copyright | This work may not be copied for profit gain | Excel!




ECHO URR QUESTIONS AND ANSWER |
LATEST UPDATE
You identify a PFO on an echo and the cardiologist asks you to calculate the LAP. How will

you perform this calculation?


✓ -:- Measure the peak velocity across the PFO, calculate the peak

pressure gradient across the defect and add the RAP.




The mitral deceleration time is 300msec. What is the valve area? A) 1.3cm^2 B) 2.8cm^2 C)

2.5cm^2 D) 1.5cm^2


✓ -:- C) 2.5cm^2 MVA = 759 / deceleration time




Which of the following is preferred to document motion of the disk in a St. Jude valve?


✓ -:- M-mode. M-mode is used to doc the MOTION of ball/disk in a

mechanical valve. Doppler is used to assess the FLOW of the valve.




A patient presents for an echo to rule out WMA. The TTE 2D exam is suboptimal. What

should you do next? A) cancel the order and dismiss the patient B) consult the physician for

permission to perform contrast imaging C) cancel the order and schedule the patient for a

TEE D) contact the ordering physician to recommend that an MRI exam is ordered instead




1|P a g e | G r a d e A + | 2 0 2 0 2 5

,2024 /2025 | © copyright | This work may not be copied for profit gain | Excel!



✓ -:- B) consult the physician for permission to p erform contrast imaging;

Suboptimal imaging of the LV wall motion on a 2D exam is an indication

for contrast administration. A physician order for the contrast must be

given, prior to performing the contrast exam.




Which Doppler measurement of flow through a stenotic AV best correlated w/ the same

value obtained during heart catheterization?


✓ -:- mean pressure gradient




Which of the following cardiac abnormalities requires the use of the continuity equation for

proper calculation of AVA? A) decreased LV function B) HOCM C) supravalvular AS


D) Transcatheter AVR


✓ -:- A) decreased LV function; The continuity equation compensates for

the changes in LV function when calculating AVA. CW Doppler is used to

assess flow across the AV. Because CW Doppler has no ran ge resolution,

it cannot determine the location of the elevated velocity. HOCM and

supravalvular stenosis will cause an improper AVA calculation b/c the

stenosis is not at the valve. A transcatheter AV replacement relies on the

pressure gradients and the velocity ratio to assess stenosis.




The peak velocity of PI can be used to assess:


2|P a g e | G r a d e A + | 2 0 2 0 2 5

,2024 /2025 | © copyright | This work may not be copied for profit gain | Excel!


A) Peak systolic pulmonary artery pressure


B) mean pulmonary artery pressure


C) pulmonary artery end diastolic pressure


D) severity of pulmonary stenosis


✓ -:- B) mean pulmonary artery pressure; MPAP =4 x (peak velocity of

PI)^2 The peak velocity of PI is peak diastolic velocity so it cannot be

used to assess systolic pressure. The end diastolic velocity of PI can be

used to assess the end diastolic pressure in t he PA.




If the LVOT Doppler tracing is obtained from a location that is too far from the AV:


A) the SV will be overestimated


B) the AVA will be overestimated by the continuity equation


C) the LVOT velocity will be overestimated


D) the AVA will be underestimated by continuity equation


✓ -:- D) the AVA will be underestimated by continuity equation; If the

Doppler cursor is placed too far from the AV, the LVOT peak velocity

will be reduced from what it would be at the correct location. This will

cause the calculation of a smaller or underestimated AVA or

overestimated level of stenosis. The peak aortic velocity and pressure

gradient will not match the level of stenosis indicated by AVA.



3|P a g e | G r a d e A + | 2 0 2 0 2 5

, 2024 /2025 | © copyright | This work may not be copied for profit gain | Excel!




What Doppler measurement is necessary to calculate the end diastolic pressure in the

pulmonary artery?


A) peak pressure gradient of PI


B) peak pressure of TR


C) end diastolic velocity of PI


D) peak systolic velocity of PI


✓ -:- C) end diastolic velocity of PI; PA end diastolic pressure = 4 (end

diastolic pressure velocity of PI)^2 + RA pressure; normal PAEDP + 4 -

12mmhg




If _________________ is present, the RVSP calculation from the TR gradient is inaccurate

as the measurement of the PAP.


A) CHF


B) PI


C) PS


D) PHTN


✓ -:- C) PS; The PA pressure is used to assess the pressure in the lungs. If

the PV is stenotic, the flow velocity and resistance increase the pressures



4|P a g e | G r a d e A + | 2 0 2 0 2 5

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller TestTrackers. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $13.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

79373 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$13.49
  • (0)
  Add to cart