100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
LPI LEVEL 1 PRACTICE TEST $10.99   Add to cart

Exam (elaborations)

LPI LEVEL 1 PRACTICE TEST

 3 views  0 purchase
  • Course
  • LPI LEVEL 1
  • Institution
  • LPI LEVEL 1

LPI LEVEL 1 PRACTICE TEST

Preview 2 out of 9  pages

  • September 23, 2024
  • 9
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • LPI LEVEL 1
  • LPI LEVEL 1
avatar-seller
GEEKA
LPI LEVEL 1 PRACTICE TEST
Which one of the following conditions will affect the rate and the extent a liquid
penetrant will enter cracks, fissures, and other small openings? - Answers -the surface
condition of the specimen being tested

Which of the following is a commonly used classification for penetrant? - Answers -post-
emulsifiable penetrant

A generally accepted method for removing excess nonwater-washable penetrant is -
Answers -wiping and cautiously cleaning the test specimen with a cleaner-dampened
cloth

All of the following parts can be tested by the liquid penetrant method except - Answers
-a part made from a porous plastic material

Which of the following discontinuities can be found by the penetrant test method? -
Answers -a surface crack

Which of the following is generally the more acceptable method for cleaning parts prior
to penetrant testing? - Answers -vapor degreasing

All of the following methods are commonly used to clean parts prior to penetrant testing
except - Answers -power wire brushing

Cutting oils may be effectively removed from parts before penetrant testing by -
Answers -vapor degreasing

The most common type of contaminant in fluorescent penetrant fluid is - Answers -water

Black light, with a proper functioning filter in place, used for fluorescent penetrant
inspection can cause permanent damage to - Answers -none of the above

All of the following basic inspection principles apply to the penetrant methods except -
Answers -indications glow when illuminated with a black light

Subsurface discontinuities can be best detected by - Answers -none of the above

Visible penetrant may be applied by - Answers -brushing, spraying, and dipping

The first step in conducting a liquid penetrant test on a surface that has been painted is
to - Answers -completely remove the paint

When using a post-emulsification penetrant, it is necessary to apply the emulsifier: -
Answers -after the dwell time has elapsed

, When conducting a water-washable liquid penetrant test, the wet developer is applied -
Answers -after the removal of the penetrant

Which of the following surface conditions could have a detrimental effect on a liquid
penetrant test? - Answers -a wet surface, a rough weld, and an oily surface

Liquid penetrant testing is capable of detecting - Answers -discontinuities open to the
surface

Black light equipment is required when penetrant testing by - Answers -the fluorescent
penetrant method

The term used to define the tendency of certain liquids to penetrate into small openings
such as cracks or fissures is - Answers -capillary action

Excess penetrant (all penetrant except that which is in discontinuities) is removed from
the specimen - Answers -after the required penetrant dwell time has elapsed

When using a post-emulsifiable penetrant, the emulsifier time should be - Answers -only
as long as necessary to remove the interfering background

when an inspector is working in a darkened area, he/she should become adjusted to the
dark before inspecting parts. The generally accepted time period for becoming
accustomed to the dark is - Answers -5 to 10 minutes

when applying penetrant by dipping, heating the penetrant prior to dipping - Answers -is
not generally recommended

A penetrant inspection cannot find - Answers -an internal cavity

All of the following materials can be tested by the usual liquid penetrant tests except -
Answers -unglazed porous ceramic

Liquid penetrant testing can be used to detect - Answers -discontinuities open to the
surface

Which of the following are commonly accepted methods for applying penetrant? -
Answers -dipping the part in penetrant (dipping), pouring the penetrant over the test
specimen (flowing), and spraying the penetrant on the test specimen (spraying)

A solvent used to clean the surface of a test specimen must possess all of the following
characteristics except that the - Answers -cleaner must not be flammable

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller GEEKA. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $10.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

81113 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$10.99
  • (0)
  Add to cart