What degree is used for isometric drawings? - Answer-60 degrees What is the recommended minimum of minutes for chlorine water management? - Answer-20-30 minutes When you need to repair a single handle lavatory faucet, what needs to be replaced? - Answer-O ring Galvanic corrosion of water s...

[Show more]

Preview 3 out of 16  pages

  • September 25, 2024
  • 16
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Plumbing
  • Plumbing
avatar-seller
lectknancy
Journeyman and Master Plumbing Exam
Question Bank Exam Questions with
Correct Answers
What degree is used for isometric drawings? - Answer-60 degrees

What is the recommended minimum of minutes for chlorine water management? -
Answer-20-30 minutes

When you need to repair a single handle lavatory faucet, what needs to be replaced? -
Answer-O ring

Galvanic corrosion of water supply piping can occur where - Answer-steel pipe is joined
to a dissimilar metal pipe

Whenever necessary to make an inspection to enforce any of the provisions of the
Code, an authorized representative may enter the premises - Answer-at all reasonable
times

After completion of work and testing of sewer pipeline, who shall request inspection? -
Answer-Supervisor of job at job-site

If the Administrative Authority requests that a new type of material be used on a project,
who pays for the testing of the new material? - Answer-Contractor

When plumbing work is inspected and a "notice of correction" is served, how many days
does the contractor have to correct the work? - Answer-Within 10 days

What is the vertical distance called that is between the lowest opening of a pipe fixture
or appurtenance that is discharging waste to the overflow level of a fixture? - Answer-
Airgap, drainage

A cleanout which has direct access without the necessity of removing any panel or door
is defined to be - Answer-readily accessible

Distribution of water from any other source than intended is - Answer-backflow

Back-siphonage is defined as - Answer-the flowing back of used, contaminated or
polluted water from a plumbing fixture or vessel into a water supply pipe due to a
negative pressure in such pipe

The _________________________ is the pipe which carries potable water from a water
meter to a building. - Answer-building supply

,Backflow is defined as - Answer-non-potable water or other liquids entering a potable
water system

Any group of two or more similar adjacent fixtures that discharge into a common
horizontal waste branch is defined as a - Answer-battery

Which of the following connects one or more individual vents to a vent stack? - Answer-
Branch vent

A combination waste and vent system may be installed on a
_______________________ piping system. - Answer-horizontal

The minimum level at which a vacuum breaker may be installed above the flood level
rim of the device and service is called - Answer-the critical level

The "the critical level" is shown on a backflow prevention device by a
_______________ marking. - Answer-C-L or C/L

When a backflow prevention device does not bear a "critical level" marking, which part
of the device constitutes the critical level? - Answer-Bottom

What is the Critical Level on a backflow device? - Answer-Bottom

According to the Uniform Plumbing Code, a "cross connection" is defined as - Answer-a
connection through which non-potable water may enter a potable water system.

What is the name for the measurement taken along the centerline of a pipe and fittings?
- Answer-Developed length

"Existing work" is defined to be a plumbing system or any part thereof which - Answer-
has been installed prior to the effective date of the code.

A pipe which makes an angle of not more than 45 degrees with the horizontal is
considered - Answer-horizontal

A horizontal pipe is any pipe or fitting which is installed in a horizontal position or which
makes an angle of less than _________ degrees with the horizontal. - Answer-45

What statement is true about industrial waste? - Answer-It is free of fecal matter.

The "invert" elevation of a sewer line is the ____________________ of the pipe. -
Answer-inside bottom

, Water which is satisfactory for drinking, culinary and domestic purposes and meets the
requirements of the health authority having jurisdiction is defined as
_____________________ water. - Answer-potable

Refer to the illustration above. This is a multi-story installation. There is a sink draining
into the pipe above "A". What is the name for the pipe at "A"? - Answer-soil stack

With an on-demand water heater, no relief is required if the maximum inside heater is -
Answer-3 "

Any liquid waste containing animal or vegetable matter is called - Answer-sewage

That portion of the drainage system composed of the pipe from the fixture trap to the
vent serving that fixture is the _________________________. - Answer-trap arm

Refer to the illustration above. The trap seal in the illustration above is indicated by
dimension - Answer-B

Refer to the same illustration. The trap seal is the distance from the crown weir (bottom
of outlet) to the upper dip and shall not be less than 2 inches nor greater than _______
inches. - Answer-4

A trap arm is that portion of a fixture drain between the trap and the
_________________________________. - Answer-vent which serves it

The trap seal is indicated by _______________________________. - Answer-crown
weir to upper dip

A vent connecting a soil waste stack to a vent stack to prevent pressure changes. -
Answer-yoke vent

When preparing to ream a pipe, what should be done first? - Answer-Remove all chips

Where can you use a double hub cross sanitary tee? - Answer-horizontal to vertical

What type of pipe should never be threaded? - Answer-Cast iron

Enlargement of a 3" closet bend, or stub, to 4" is - Answer-permitted by this Code

True/False: A closet bend may be connected to a pipe which is the same size or larger.
- Answer-True

Refer to the illustration above. A trench runs parallel to the rooting of the building and is
deeper than the footing. What minimum angle is permitted at "A"? - Answer-45 degrees

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller lectknancy. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $16.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

79223 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$16.49
  • (0)
  Add to cart