100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

NHA EKG Technician Practice Test Questions and Answers | 100% Pass

Rating
-
Sold
-
Pages
33
Grade
A+
Uploaded on
25-09-2024
Written in
2024/2025

NHA EKG Technician Practice Test Questions and Answers | 100% Pass Which of the following EKG machine functions should an EKG technician use to control and regulate the height of EKG waveforms on the tracing? a. Speed b. Output display c. Artifact filter d. Gain - Correct Answer️️ -d. Gain Which of the following methods should a EKG technician use when removing hair from electrode placement sites for telemetry monitoring? a. Dry shave b. Wet shave c. Tape d. Clippers - Correct Answer️️ -d. Clippers An EKG technician notes periods of sinus arrest on a patient's EKG tracing. The technician should consider the sinus arrest to be a medical emergency when the arrest reaches which of the following durations? a. 6 sec b. 4 sec TITLE: EMILLYCHARLOTTE 2024/2025 ACADEMIC PERIOD OWNER: EMILLYCHARLOTTE COPYRIGHT STATEMENT: ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED FIRST PUBLISHED: SEPTEMBER 2024 2/33 c. 3 sec d. 1 sec - Correct Answer️️ -a. 6 sec Which of the following lead groups are bipolar leads? a. Leads aVR, aVL, and aVF b. Leads I, II, and III c. Leads V1, V2, and V3 d. Leads V4, V5, and V6 - Correct Answer️️ -b. Leads I, II, III An EKG technician is performing a second standard 12-lead EKG on a patient immediately following the first test. For which of the following reasons should the technician recognize that resting tab electrodes should not be used for more than two consecutive EKG tracings? a. The electrodes cannot conduct the signal after two EKG tracings b. The electrodes will not conduct accurately after two EKG tracings c. The electrodes need to be cleaned after two EKG tracings d. The electrodes will not re-adhere to the skin after being removed between tracings - Correct Answer️️ -b. The electrodes will not conduct accurately after two EKG tracings In which of the following locations should an EKG technician place the electrode for leavd V5? a. On the left midaxillary line, horizontal to lead V4 b. On the left anterior axillary line, horizontal to lead V4 TITLE: EMILLYCHARLOTTE 2024/2025 ACADEMIC PERIOD OWNER: EMILLYCHARLOTTE COPYRIGHT STATEMENT: ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED FIRST PUBLISHED: SEPTEMBER 2024 3/33 c. On the left midclavicular line, fifth intercostal space d. On the right margin of the sternum, fourth intercostal space - Correct Answer️️ -b. On the left anterior axillary line, horizontal to lead V4 An EKG technician is working with a patient who has a below-the-knee amputation of the left leg. In which of the following locations should the technician place the right leg electrode? a. On the lower right foot b. On the lower right abdomen c. On the lower left torso d. On the lower right leg - Correct Answer️️ -b. On the lower right abdomen Which of the following methods should an EKG technician use to store electrodes when not in use? a. Loose in the EKG cart b. In a folded paper bag c. In an open plastic bag d. In the original, foil-lined packaging - Correct Answer️️ -d. In the original, foil-lined packaging A serial EKG tracing shows a rhythm that does not ma

Show more Read less
Institution
Course











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Course

Document information

Uploaded on
September 25, 2024
Number of pages
33
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

TITLE: EMILLYCHARLOTTE 2024/2025 ACADEMIC PERIOD
OWNER: EMILLYCHARLOTTE
COPYRIGHT STATEMENT: ©2024 EMILLYCHARLOTTE. ALL RIGHTS
RESERVED
FIRST PUBLISHED: SEPTEMBER 2024

NHA EKG Technician Practice Test
Questions and Answers | 100% Pass

Which of the following EKG machine functions should an EKG technician use to control

and regulate the height of EKG waveforms on the tracing?

a. Speed

b. Output display

c. Artifact filter

d. Gain - Correct Answer✔️✔️-d. Gain

Which of the following methods should a EKG technician use when removing hair from

electrode placement sites for telemetry monitoring?

a. Dry shave

b. Wet shave

c. Tape

d. Clippers - Correct Answer✔️✔️-d. Clippers

An EKG technician notes periods of sinus arrest on a patient's EKG tracing. The

technician should consider the sinus arrest to be a medical emergency when the arrest

reaches which of the following durations?

a. 6 sec

b. 4 sec

1/33

,TITLE: EMILLYCHARLOTTE 2024/2025 ACADEMIC PERIOD
OWNER: EMILLYCHARLOTTE
COPYRIGHT STATEMENT: ©2024 EMILLYCHARLOTTE. ALL RIGHTS
RESERVED
FIRST PUBLISHED: SEPTEMBER 2024
c. 3 sec

d. 1 sec - Correct Answer✔️✔️-a. 6 sec

Which of the following lead groups are bipolar leads?

a. Leads aVR, aVL, and aVF

b. Leads I, II, and III

c. Leads V1, V2, and V3

d. Leads V4, V5, and V6 - Correct Answer✔️✔️-b. Leads I, II, III

An EKG technician is performing a second standard 12-lead EKG on a patient

immediately following the first test. For which of the following reasons should the

technician recognize that resting tab electrodes should not be used for more than two

consecutive EKG tracings?

a. The electrodes cannot conduct the signal after two EKG tracings

b. The electrodes will not conduct accurately after two EKG tracings

c. The electrodes need to be cleaned after two EKG tracings

d. The electrodes will not re-adhere to the skin after being removed between tracings -

Correct Answer✔️✔️-b. The electrodes will not conduct accurately after two EKG tracings

In which of the following locations should an EKG technician place the electrode for

leavd V5?

a. On the left midaxillary line, horizontal to lead V4

b. On the left anterior axillary line, horizontal to lead V4


2/33

,TITLE: EMILLYCHARLOTTE 2024/2025 ACADEMIC PERIOD
OWNER: EMILLYCHARLOTTE
COPYRIGHT STATEMENT: ©2024 EMILLYCHARLOTTE. ALL RIGHTS
RESERVED
FIRST PUBLISHED: SEPTEMBER 2024
c. On the left midclavicular line, fifth intercostal space

d. On the right margin of the sternum, fourth intercostal space - Correct Answer✔️✔️-b.

On the left anterior axillary line, horizontal to lead V4

An EKG technician is working with a patient who has a below-the-knee amputation of

the left leg. In which of the following locations should the technician place the right leg

electrode?

a. On the lower right foot

b. On the lower right abdomen

c. On the lower left torso

d. On the lower right leg - Correct Answer✔️✔️-b. On the lower right abdomen

Which of the following methods should an EKG technician use to store electrodes when

not in use?

a. Loose in the EKG cart

b. In a folded paper bag

c. In an open plastic bag

d. In the original, foil-lined packaging - Correct Answer✔️✔️-d. In the original, foil-lined

packaging

A serial EKG tracing shows a rhythm that does not match the last tracing that the EKG

technician performed. Which of the following actions should the technician take first?

a. Connect the patient to a different EKG machine.


3/33

, TITLE: EMILLYCHARLOTTE 2024/2025 ACADEMIC PERIOD
OWNER: EMILLYCHARLOTTE
COPYRIGHT STATEMENT: ©2024 EMILLYCHARLOTTE. ALL RIGHTS
RESERVED
FIRST PUBLISHED: SEPTEMBER 2024
b. Report the finding to the provider

c. Verify proper lead placement

d. Perform a maintenance check on the machine - Correct Answer✔️✔️-c. Verify proper

lead placement

Which of the following statements made by an EKG technician correctly prepares the

patient for telemetry monitoring?

a. "I will clean your skin with an alcohol pad"

b. "You may feel a slight warming sensation after the electrodes are placed on the skin"

c. "A mild rash or skin redness should be expected around the electrodes after 24

hours."

d. "Electrodes will be replaced once per week while you're in the hospital." - Correct

Answer✔️✔️-a. "I will clean your skin with an alcohol pad"

An EKG technician is performing a standard 12-lead EKG on a patient who is 4 years

old. In which of the following locations should the technician place the V6 electrodes?

a. Right midclavicular space

b. Left midclavicular space

c. Right midaxillary line

d. Left midaxillary line - Correct Answer✔️✔️-d. Left midaxillary line

Which of the following sections of the EKG tracing should an EKG technician use to

measure the QRS complex?


4/33
$12.99
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached


Also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EmillyCharlotte Howard Community College
Follow You need to be logged in order to follow users or courses
Sold
98
Member since
1 year
Number of followers
5
Documents
11948
Last sold
1 week ago
ALL-MAJOR.

On this page, you find all documents, package deals, and flashcards offered by seller Emilly Charlotte.

3.5

21 reviews

5
7
4
6
3
2
2
3
1
3

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions