Exam (elaborations)
California Fluoroscopy State Board Exam Questions and Answers
Course
California Fluoroscopy Supervisor and Operator
Institution
California Fluoroscopy Supervisor And Operator
California Fluoroscopy State Board Exam Questions and Answers
[Show more]
Preview 4 out of 68 pages
Uploaded on
September 30, 2024
Number of pages
68
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
Institution
California Fluoroscopy Supervisor and Operator
Course
California Fluoroscopy Supervisor and Operator
$16.49
100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached
California Fluoroscopy State Board
Exam Questions and Answers
What iidigital iifluoroscopic iiimaging iitechnique iiutilizes iichanging iimasks, iiwhich
iiprovides iiinformation iiof iichanges iiin iicontrast iimedia iicontent iiwithin iia iistructure ii
1.Time iiinterval iidifference iiimaging ii
2. iiMask iimode iifluoroscopy
3. iiK ii-edge iifluoroscopy
4. iiSynchronized iifluoroscopy ii- iiCorrect iiAnswers ii-1. iiTime iiinterval iidifference iiimaging
All iiof iithe iifollowing iiwill iidirectly iiinfluence iithe iitable-top iiexposure iirate iiexcept
1. iiLight iiin iithe iifluoroscopy iiroom
2. iikVp
3. iiTarget iito iipanel iidistance
4. iiFiltration ii- iiCorrect iiAnswers ii-1. iiLight iiin iithe iifluoroscopy iiroom
Attenuation iiof iia iiradiation iibeam's iiintensity iias iiit iipasses iithrough iian iiabsorber iiis
iigoverned iiby
1. iiTime
2. iiThe iispecific iimediums iidensity
3. iiThe iienergy iiof iithe iiradiation
4. iiThe iithickness iiof iithe iiabsorber iitraversed ii- iiCorrect iiAnswers ii-2. iiThe iispecific
iimediums iidensity
3. iiThe iienergy iior iiradiation
4. iiThe iithickness iiof iithe iiabsorber iitraversed
What iirecording iimedium iiwill iiresult iiin iithe iileast iirecorded iiresolution
1. iiSpot iifilms iiusing iia iispot iifilm iicamera
2. iivideo iitape iirecording
3. iispot iifilms iiusing iiconventional iicassettes
4. iivideo iidisc iirecording ii- iiCorrect iiAnswers ii-2. iivideo iitape iirecording
During iithe iiperiod iiwhen iian iiindividual iireceives iian iioccupational iidose, iithey iiare ii_
iiconsidered iito iibe iia ii"member iiof iithe iipublic"
1. iisometimes
2. iialways
3. iiit iidepends
,4. iinever ii- iiCorrect iiAnswers ii-4.never
A iiperson iiwearing iia ii_ iiapron iiwill iireduce iitransmitted iiexposure iito iiapproximately
ii99.9% iiof iithe iiincident iiscatter iidose
1. ii1.5 iimm iiPb iiequivalent ii
2. ii0.50 iimm iiPb iiequivalent
3. ii0.25 iimm iiPb iiequivalent
4. ii1.0 iimm iiPb iiequivalent ii- iiCorrect iiAnswers ii-2. ii0.50 iimm iiPb iiequivalent
If iithe iiinput iiphosphor iiof iian iiimage iiintensifier iimeasures ii15 iiinches iiin iidiameter iiand
iithe iioutput iiphosphor iimeasures ii1.0 iiinches, iithe iiminification iigain iiwould iibe
1. ii30
2. ii225
3. ii175
4. ii300 ii- iiCorrect iiAnswers ii-Minification iiGain ii= ii{15(2) ii= ii225} iiinput iiscreen iidiameter
ii(2) ii/ ii{1.0 ii(2) ii= ii1} iioutput iiscreen iidiameter ii(2) ii= ii225/1= ii225
What iielectronic iisystem iiis iidesigned iito iihelp iimaintain iia iiconsistent iilevel iiof iiimage
iibrightness
1. iiphoto-emitter
2. iiautomatic iibrightness iistabilizer
3. iicamera iicontrol iiunit ii
4. iividicon ii- iiCorrect iiAnswers ii-2. iiautomatic iibrightness iistabilizer
Energy iisubtraction iias iiused iiin iidigital iifluoroscopy iiexhibits iiless ii_ iithan iitemporal
iisubtraction
1. iicomplexity
2. iix-ray iiintensity
3. iikVp
4. iimotion iiartifact ii- iiCorrect iiAnswers ii-4. iimotion iiartifact
Bone iimarrow iidose iiis iimeasured
1. iidirectly iifrom iibone iimarrow
2. iias iiestimate iifrom iigonadal iidose
3. iias iian iiestimate iifrom iiESE
4. iidirectly iifrom iithe iibeam ii- iiCorrect iiAnswers ii-3. iias iian iiestimate iifrom iithe iiESE
The iiPrivacy iiRule iiis iimeant iito iiensure iithat iithere iiis/are ii
1. iisecurity iiof iielectronic iipersonal iihealth iiinformation
2. iistandardization iiof iielectronic iipatient iihealth iidata
3. iilimits iiPHI iito iia ii"need iito iiknow.." iibasis iito iicarry iiout iimedical iitreatment
4. iiall iithe iilisted iianswers ii- iiCorrect iiAnswers ii-4. iiall iithe iilisted iianswers
To iiprovide iiillumination iistability iiof iithe iivirtual iiimage iiduring iifluoroscopy, iimost
iimodern iiunits iiwill iiautomatically iiadjust iiradiation iilevels iifor iimore iidense iiand iimore
iiradiolucent iibody iiparts. iiThis iifunctionality iiis iiknown iias:
,1. iivelling iiglare
2. iiimage iiflare
3. iiautomatic iiadaption
4. iiautomatic iibrightness iicontrol ii- iiCorrect iiAnswers ii-4. iiautomatic iibrightness iicontrol
The iielectronic iisignal iiwhich iicarries iiimage iiinformation iifrom iia iitelevision iicamera iito
iia iiviewing iimonitor iiis iitermed iithe:
1. iivideo iisignal
2. iireturn iibeam
3. iisynchronization iipulse
4. iibandpass ii- iiCorrect iiAnswers ii-1. iivideo iisignal
If iionly iione iipersonnel iimonitoring iidevice iiis iiworn, iiit iimust iibe iilocated
1. iiunder iithe iiapron iiat iithe iicollar iilevel ii
2. iioutside iithe iiapron iiat iithe iigonad iilevel
3. iioutside iithe iiapron iiat iithe iicollar iilevel ii- iiCorrect iiAnswers ii-3. iioutside iithe iiapron iiat
iithe iicollar iilevel
The iirandom iipattern iiof iiincident iiradiation, iiwhich iioften iiresults iiin iithe iiappearance iiof
ii"snow" iior ii"mottle" iiwhen iiviewing iithe iivirtual iiimage iiis iicalled
1. iiflicker iieffect
2. iilens iiopacity
3. iiquantum iinoise
d. iivignetting ii- iiCorrect iiAnswers ii-3. iiquantum iinoise
When iiwearing iia ii"film iibadge" iias iia iipersonnel iimonitoring iidevice, iiit iimust iibe
iipositioned ii
1. iiat iiwaist iilevel ii
2. iiat iicollar iilevel ii
3. iiunder iithe iiprotective iiapron ii
4. iioutside iithe iiprotective iiapron ii- iiCorrect iiAnswers ii-b. ii2 iiand ii4
Which iiof iithe iifollowing iiare iiconsidered iito iibe iiadvantages iiof iiusing iia iifilm iibadge iifor
iiradiation iimonitoring
1. iiinexpensive
2. iireusable ii
3. iiprovides iia iipermanent iirecord ii
4. iiprovides iian iiobjective iireview iiof iiexposure iihistory ii- iiCorrect iiAnswers ii-c. ii1 iiand ii3
which iiof iithe iifollowing iistatements iiis iitrue iiwith iirespect iito iiobtaining iia iimedical
iihistory iifor iia iiradiographic iiexamination ii
1. iishould iiinclude iiany iipertinent iiinformation iiabout iithe iipatient iiand iiindicated iithe
iireason iifor iithe iiexamination ii
2. iiis iinot iiconsidered iiconfidential iiinformation
3. iirequired iionly iifor iiinpatients
, 4. iiis iialways iiobtained iiby iithe iiradiologist ii- iiCorrect iiAnswers ii-1. iishould iiinclude iiany
iipertinent iiinformation iiabout iithe iipatient iiand iiindicated iithe iireason iifor iithe
iiexamination
In iia iitelevision iisystem, iithe iiratio iibetween iithe iivertical iiresolution iiand iithe iinumber iiof
iihorizontal iiscan iilines iiis iicalled iithe ii
1. iiline iirate iifactor
2. iikell iifactor
3. iiconversion iifactor
4. iiresolution iifactor ii- iiCorrect iiAnswers ii-2. iikell iifactor
In iian iiimage iiintensification iitube, iito iiprevent iilight iifrom iiscattering iiback iitowards iithe
iiphoto iicathode iilayer, iia iithin iisheet iiof iialuminum iiis iiplaced iionto iithe ii:
1. iioutput iiphosphor
2. iiaccelerating iianode
3. iiphoto iicathode
4. iiinput iiphosphor ii- iiCorrect iiAnswers ii-output iiphosphor
Digital iiphoto iispot iiimage iirecording iiprovides iiwhich iiof iithe iifollowing iiadvantages
1. iiinstant iiimage iiplayback ii
2. iielectronic iiimage iienlargement ii
3. iiimproved iiresolution iiover iiconventional iispot iifilm
c. ii1,2 iiand ii3
d. ii1 iionly ii- iiCorrect iiAnswers ii-c. ii1,2 iiand ii3
California iistate iiregulations iistate iithe iitarget iito iipanel iior iitarget iito iitable ii
1. iishall iinot iibe iimore iithan ii18 iiinches
2. iishall iinot iibe iiless iithan ii12 iiinches
3. iishould iinot iibe iiless iithan ii12 iiinches
4. iishould iinot iibe iimore iithan ii18 iiinches ii- iiCorrect iiAnswers ii-2. iishall iinot iibe iiless
iithen ii12 iiinches
which iiprotective iibarrier iiis iiused iito iiattenuate iistray iiradiation
1. iisecondary iiprotective iibarrier
2. iix-ray iitube iihousing
3. iiprimary iiprotective iibarrier
4. iiuseful iibeam iibarrier ii- iiCorrect iiAnswers ii-3. iiprimary iiprotective iibarrier
During iiwhich iiperiod iiof iitime iidoes iia iigenerator iioperating iiin iithe ii"pulse iiprogressive
iifluoroscopy" iimode iiproduce iiusable iixray iiphotons
1. iiduty iicycle
2. iiextinction iiphase
3. iiinterrogation iiphase ii- iiCorrect iiAnswers ii-1. iiduty iicycle
The iisquared iiratio iiof iian iiinput iiscreen iidiameter iito iian iioutput iiscreen iidiameter iiis
iicalled: ii