100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

Fluoroscopy Chapter 36 Exam Questions with All Correct Answers

Rating
5.0
(1)
Sold
-
Pages
14
Grade
A+
Uploaded on
01-10-2024
Written in
2024/2025

Fluoroscopy Chapter 36 Exam Questions with All Correct Answers Which of the following require the x-ray beam to be in radiographic mode? Cassette spot filming Film cameras for spot filming Videotape None of the above - Answer- Cassette spot filming This recording system uses 70 mm or 105 mm film. Cassette spot filming Film cameras for spot filming Videotape None of the above - Answer- Film cameras for spot filming This recording system allows the film to be divided into two, four, or more images. Cassette spot filming Film cameras for spot filming Videotape None of the above - Answer- Cassette spot filming In order to record the dynamic image you will need to use: Cassette spot filming Film cameras for spot filming Videotape None of the above - Answer- Videotape The recording device that "photographs" the image off of the output phosphor is the: Cassette spot filming Film cameras for spot filming Videotape None of the above - Answer- Film cameras for spot filming Early versions of digital fluoroscopy used the standard system and added: A different camera An ADC Videotape None of the above - Answer- An ADC The analog to digital converter: Makes the electrical signal understandable to the computer Determines the contrast resolution of the system Determines the image matrix All of the above - Answer- All of the above

Show more Read less
Institution
Fluoroscopy
Course
Fluoroscopy

Content preview

Fluoroscopy Chapter 36 Exam
Questions with All Correct
Answers

Which of the following require the x-ray beam to be in radiographic mode?
Cassette spot filming
Film cameras for spot filming
Videotape
None of the above - Answer- Cassette spot filming

This recording system uses 70 mm or 105 mm film.
Cassette spot filming
Film cameras for spot filming
Videotape
None of the above - Answer- Film cameras for spot filming

This recording system allows the film to be divided into two, four, or more images.
Cassette spot filming
Film cameras for spot filming
Videotape
None of the above - Answer- Cassette spot filming

In order to record the dynamic image you will need to use:
Cassette spot filming
Film cameras for spot filming
Videotape
None of the above - Answer- Videotape

The recording device that "photographs" the image off of the output phosphor is the:
Cassette spot filming
Film cameras for spot filming
Videotape
None of the above - Answer- Film cameras for spot filming

Early versions of digital fluoroscopy used the standard system and added:
A different camera
An ADC
Videotape
None of the above - Answer- An ADC

, The analog to digital converter:
Makes the electrical signal understandable to the computer
Determines the contrast resolution of the system
Determines the image matrix
All of the above - Answer- All of the above

Digital fluoroscopy is improved by using:
A vidicon camera
Videotape
A beam splitting mirror
A CCD - Answer- CCD

Which of the following is more light-sensitive?
Tube-type camera
CCD
There is no difference between the two. - Answer- CCD

Which of the following produces an image with more noise?
Tube-type camera
CCD
There is no difference between the two. - Answer- Tube-type camera

Which of the following has more spatial distortion?
Tube-type camera
CCD
There is no difference between the two. - Answer- Tube-type camera

In comparison, the vidicon camera tube has ______________ spatial resolution, and
the CCD requires ________________ radiation to produce a good fluoroscopic image.
Less; more
Less; less
Better; more
Better; less - Answer- Less; less

Use of which of the following systems will result in less radiation dose to the patient?
Tube-type camera
CCD
There is no difference between the two. - Answer- CCD

The newest fluoroscopy systems use a flat-panel detector:
To display the spot images during fluoroscopy
To record the overhead images following fluoroscopy
In place of the image intensifier
In addition to the image intensifier - Answer- In place of the image intensifier

Flat-panel detectors for fluoroscopic imaging can be the:

Written for

Institution
Fluoroscopy
Course
Fluoroscopy

Document information

Uploaded on
October 1, 2024
Number of pages
14
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Reviews from verified buyers

Showing all reviews
11 months ago

5.0

1 reviews

5
1
4
0
3
0
2
0
1
0
Trustworthy reviews on Stuvia

All reviews are made by real Stuvia users after verified purchases.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Scholarsstudyguide nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
805
Member since
3 year
Number of followers
476
Documents
15680
Last sold
2 hours ago
NURSING

Here you will find everything you need in nursing Assignments, EXAMS AND TESTBANKS. For students who want to see results twice as fast. I strive for my content to be of the highest quality. Always leave a review after purchasing any document so as to make sure our customers are 100% satisfied.

3.9

165 reviews

5
87
4
21
3
27
2
6
1
24

Trending documents

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions