NICET LEVEL STUDY GUIDE 1 EXAM 100 When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water level _____________from the required level (NFPA 72, Table 14.4.3.2 17 (j) (4) - ANS rises or falls over 3 inc$12.99
Add to cart
NICET LEVEL STUDY GUIDE 1 EXAM 100 When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water level _____________from the required level (NFPA 72, Table 14.4.3.2 17 (j) (4) - ANS rises or falls over 3 inc
5 views 0 purchase
Course
Nicet
Institution
Nicet
When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water level _____________from the required level
(NFPA 72, Table 14.4.3.2 17 (j) (4) - ANS rises or falls over 3 inches
If combination audible/visible appliances are installed the location o...
ck
QUESTIONS WITH
DETAILED ANSWERS | A+
lo
GRADE ASSURED //
yc
LATEST
ud
st
, When testing a water level supervisory switch serving a pressure tank a signal shall indicate if
the water level _____________from the required level
(NFPA 72, Table 14.4.3.2 17 (j) (4) - ANS rises or falls over 3 inches
If combination audible/visible appliances are installed the location of the installed appliance shall
be determined by the requirements of _______.
ck
(Nfpa 72 18.4.8.1) - ANS the visible appliance
What is the maximum number of 12 gauge THHN wires that can be installed in 1" EMT?
(Nec Annex C tables) - ANS 26
lo
Two resistors are connected in parallel. R1 = 300 Ohms, R2 = 300 Ohms. What is their
equivalent resistance? - ANS 150 ohms
yc
The room is 200' long and 150' wide and the 8' high ceiling is smooth and flat. A spot type heat
detector has been selected that is listed for a 50' maximum spacing between detectors.
According to NFPA 72 how many detectors will be needed to protect this room?
x = - ANS 12
ud
According to NFPA 72 the minimum number of restorable fixed temperature spot type heat
detectors that must be tested during each annual test is?
(NFPA 72 14.4.4.5.1) - ANS Two detectors or more on each initiating device circuit
st
According to NFPA 72 how many spot type heat detectors are required for a space that is 80'
long and 55 floor wide with a smooth 10' ceiling? the detector is listed for a maximum space
between detectors of 30' - ANS 6
What color code requirement for a spot type heat detector rated at 200゚F - ANS White (NFPA
72, Table 17.6.2.1)
Unless otherwise recommended by the manufacturers published instructions, single and
multiple stations smoke alarms installed in one and 2 family dwellings shall be replaced every -
ANS 10 years from the day-of manufacture. (NFPA 72, 14.4.7.1)
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller Studyclock. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $12.99. You're not tied to anything after your purchase.