100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Fire Alarm Guide Questions with Solutions 2024 $13.99
Add to cart

Exam (elaborations)

Fire Alarm Guide Questions with Solutions 2024

 6 views  0 purchase
  • Course
  • Fire Alarm
  • Institution
  • Fire Alarm

Exam of 34 pages for the course Fire Alarm at Fire Alarm (Fire Alarm Guide)

Preview 4 out of 34  pages

  • October 3, 2024
  • 34
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Fire Alarm
  • Fire Alarm
avatar-seller
julianah420
Fire Alarm Guide

Both audible and visual alarm indication shall be supervised - answer True

Speakers are permitted for voice communication only - answer False

Private Mode audible signal appliance minimum sound level of - answer45 dBA at 10' --
10 dBA above average, 5 dBA above maximum sound level; whatever is greater
measured at 5' above floor.

A signal indicating an emergency requiring immediate action is an - answeralarm signal

Where Public Mode audible appliances are installed they shall be ____________ above
average ambient sound level - answer15 dBA

An alarm silencing switch, a means for silencing the trouble notification appliance shall
be permitted only if _________ - answerIt is key-operated or located within a local
cabinet
It will give a trouble signal if left in the "silence" position when no alarm exists
It will transfer indication of an alarm to a visual indicator

What is the sound made by one or more audible notification appliances such as bells or
horns in response to the operation of an initiating device? - answerAudible alarm

Where audible appliances are installed in mechanical equipment rooms, the average
ambient sound level is - answer85 dBA

Alarm sounding appliances are installed in mechanical equipment rooms, the average
ambient sound level is? - answer85 dBA

Wall mounted audio/visible notification appliance must be at least 6' 8" above the floor
but not more than ____________ above the floor - answer96"

Sleeping area where audible appliances are installed shall be ____________ above the
average ambient sound level - answer15 dBA

The light appliance source color shall be clear or nominal white and shall not exceed -
answer1000 candela

Where ceiling heights allow, wall mounted audible appliances shall have their tops
above the finished floors at heights of not less than - answer90"

,Wall mounted telephone where accessible to the general public, one telephone per
location shall be no higher than - answer48"

Wall mounted visible notification appliance must be at least 6' 8" above the floor but not
more than _______ above the floor - answer96"

The visible appliances shall be located no more than ____________ from the end of the
corridor with separation no more than __________ between visible appliances -
answer15', 100'

In a dwelling unit the detectors shall be wired in such a manner that actuation of one
alarm will actuate _________ alarms - answerAll

Loud speakers shall have a mounting height of _____ or _____ below the ceiling -
answer90", 6"

Household Audible alarms must produce a prevailing sound higher than ______ at 10' -
answer75 dBA

Audible alarms may have a mounting heights of ____ or ____ below the ceiling -
answer90", 6"

An average ambient sound level greater than ______ shall require the use of a visible
notification appliance - answer105 dBA

Manual fire alarm boxes shall not be mounted less than 3-1/2' and not more than 5'
above the finished floor - answerFalse

All fire detection devices shall be listed or approved for the purpose for which they are
intended - answerTrue

A detector should not be recessed in any way unless they have been tested for such a
mounting - answerTrue

Partitions which do not extend to the ceiling and are 18" or more from the ceiling are
considered not to have an effective smoke travel to warrant a reduction of spacing -
answerFalse

Smoke detectors listed or approved exclusively for door release service shall not be
used for open area protection - answerFalse

Smoke detectors placed in areas used to handle environmental air, such as plenum
ceiling, may be substitute for open area protection - answerFalse

Manual fire alarm boxes shall not be mounted less than 3-1/2' and not more than 4'
above the finished floor - answerTrue

,Smoke detector listed exclusively for door release shall be used for open air protection -
answerTrue

Manual pull station shall be located as near as possible and not more than five feet from
each exit - answerTrue

Detectors shall not be recessed in any way unless they have been tested and listed for
such mounting - answerTrue

The detector sensitivity cannot be tested or measured using any spare device that
administers an unmeasured concentration of aerosol into a detector - answerTrue

How far from the doorway shall a Manual fire alarm station be mounted - answer5' or as
close as AHJ says

What kind of detectors are used for door closer operation - answerPhotoelectric or
Ionization

When there is more than a _____ inch depth partition over a door or double-doors two
detectors must be installed - answer24

A bimetallic heat detector is an example of a - answerSpot-type detector

Vane type flow switch have no longer than _____ to initiate alarm - answer1-1/2
minutes

Smoke detector must be tested every - answer1 year

The principles of a smoke sensing fire detector are - answerIonization, Photoelectric,
and Projected beam

Sensitivity in smoke detectors and single & multiple-station smoke alarms in other than
1&2 family dwellings shall be checked within _____ year or years after installation -
answer1 year

Type of detector that should be installed six feet away from a florescent fixture -
answerPhotoelectric

A spot-type heat detector located on a wall, shall not be more than _____ inches from
the ceiling - answer12

A type of smoke detector which uses a small amount of radioactive material is a -
answerIonization detector

, With a peak ceiling, heat and smoke detectors shall be located within _____ of the
peak, measured horizontally - answer3'

A spot-type smoke detector located on a ceiling or, if on a sidewall, between the ceiling
and _____ down from the ceiling to the top of the detector - answer12"

Flame detectors which respond to radiant energy outside the range of human vision are
- answerInfrared and Ultraviolet detectors

Smoke detectors shall not be located - answerNear air supply diffusers

When beams project more than _____ inches below the ceiling and are more than 8' on
center, each bay formed by the beams shall be treated as a separate area for heat
detectors - answer18

When manual fire alarm boxes are used, the distance between boxes will not be in
excess of _____ - answer200'

A water flow device should be field adjusted so that an alarm is initiated in no more than
_____ seconds - answer90

Smoke detectors shall not be located directly in the air stream of _____ - answerSupply
registers

Detectors shall not be installed until after - answerFinal clean up of all trades

A flow switch is a _____ type of device - answerOn/Off

A heat detector integrally mounted on a smoke detector shall be listed for approved for
not less than ______ feet - answer50

Detectors for common return systems should be installed up to ______ in front or
behind openings - answer12"

Detectors listed for ducts shall be located _____ the last inlet or outlet upstream and the
first inlet or outlet downstream of the damper - answerBetween

Smoke detector sensitivity shall be tested _____ - answerWithin one year of installation
and every other year thereafter

A line-type obscuration smoke detector, where the light beam is projected across the
area to be protected detector - answerProjected beam smoke detector

When manual fire alarm boxes are used, the distance between boxes will not be in
excess of _____ feet - answer200

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller julianah420. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $13.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

53022 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$13.99
  • (0)
Add to cart
Added