Fire alarm systems

Maintenance of a fire alarm system is carried out by a person
A) certified by the chief electrical inspector
B) certified by the chief building inspector
C) qualified in accordance with the alberta fire code – answer C)

Maintenance of a fire alarm system can be carried out by
A) electricians certified in 1990 with no other recognized training
B) personnel qualified by the building inspector
C) qualified personnel such as a fire alarm tech - answerC)

A non sprinklered three story office complex with an occupant load of 100 persons on
floor 1, 100 persons on floor 2, and 90 persons on floor 3 shall require a fire alarm
system. True or false - answerTrue

The standard for installation and maintenance of fire alarm systems is enforced by
A) an electrical safety codes officer
B) building safety officer
C) a fire safety codes officer - answerA)

Most fixed temperature detectors would be
A) available in the 105 degree cel range
B) available in the 57 degree cel range
C) equipped with an air chamber - answerB)

True or false, smoke detectors have to be installed in every sleeping room of a one
storey hospital - answerTrue

A single stage manual pull station consists of a single pole switch operated by a pull
mechanism that will initiate an alert signal, true or false - answerFalse

True or false, a two stage system has 4 conductors in and four out - answerTrue

What signals will occur at the control panel for a conventional fire alarm system if an
open occurs in an initiating circuit? - answerTrouble

What signals will occur at the control panel for a conventional fire alarm system if there
is a short in the signal circuit? - answerTrouble

What signals will occur at the control panel for a conventional fire alarm system if there
is a short in the initiating circuit? - answerAlarm

, What signals will occur at the control panel for a conventional fire alarm system if there
is a ground fault in a water flow zone circuit? - answerGround fault and trouble

An automatic fire detector that uses a small radiation source to ionize the nearby air is a
______ - answerIonization smoke detector

An automatic flame detector that can be installed outdoors is a _____ - answerInfrared
flame detector

A sprinkler system that is typically installed in cold areas is a ______ - answerDry pipe
system

A sprinkler system that is controlled by the panel that will fill with water but will be
delayed from EACH sprinkler head until the fusible link melts is a ______ - answerPre
action system

Part of the sprinkler system that if activated will cause a supervisory condition at the
panel is a _____ - answerGate valve

An automatic fire detector that uses air pressure to detect a change in temperature is a
____ - answerRate of rise detector

A fixed temperature heat detector that is reusable is a ________ - answerBimetal heat
detector

A fixed temperature heat detector that is non reusable is a ______ - answerFusible link
heat detector

The part of the fire alarm system that provides electrical supervision, houses the CPU,
receives signals from detection devices and transmits signals to devices is a ______ -
answerControl panel

A visual indicator that displays a signal from the fire alarm system, often located at a
buildings principle entrance, seperate from the control panel is a _____ -
answerAnnunciator

A type of automatic flame detector that is sensitive to burning gasoline that cannot he
installed outside is a _____ - answerUV flame detector

A device installed in the sprinkler system that will initiate an alarm when activated is a
______ - answerWater flow

An automatic fire detector that uses a light scattering principle to detect the earliest
stages of a fire is a ______ - answerPhoto electric smoke detector

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller julianah420. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $16.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

53022 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$16.49
  • (0)
Add to cart
Added