100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
AMT AIRFRAME WRITTEN TEST (FAA) EXAM QUESTIONS AND ANSWERS UPDATED (2024/2025) (VERIFIED ANSWERS) $15.99   Add to cart

Exam (elaborations)

AMT AIRFRAME WRITTEN TEST (FAA) EXAM QUESTIONS AND ANSWERS UPDATED (2024/2025) (VERIFIED ANSWERS)

 4 views  0 purchase
  • Course
  • FAA
  • Institution
  • FAA

AMT AIRFRAME WRITTEN TEST (FAA) EXAM QUESTIONS AND ANSWERS UPDATED (2024/2025) (VERIFIED ANSWERS)AMT AIRFRAME WRITTEN TEST (FAA) EXAM QUESTIONS AND ANSWERS UPDATED (2024/2025) (VERIFIED ANSWERS)AMT AIRFRAME WRITTEN TEST (FAA) EXAM QUESTIONS AND ANSWERS UPDATED (2024/2025) (VERIFIED ANSWERS)AMT AIRF...

[Show more]

Preview 4 out of 117  pages

  • October 8, 2024
  • 117
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • FAA
  • FAA
avatar-seller
ExamitorMagnus
AMT




AMT AIRFRAME WRITTEN TEST (FAA)
EXAM QUESTIONS AND ANSWERS
UPDATED (2024/2025) (VERIFIED
ANSWERS)


B- weighing the container and its contents. - ANS ✓14 (9010) - A fire-
extinguisher container can be checked to determine its charge by


A- Brown. - ANS ✓15 (9011) - What is the color code for fire-extinguisher lines?


C- dents, kinks, or crushed sensor sections. - ANS ✓16 (9012) - The most
common cause of false fire warnings in continuous-loop fire-detection systems is


A- it generates a small current when heated. - ANS ✓17 (9013) - A
thermocouple in a fire-detection system causes the warning system to operate
because


C- rate-of-temperature rise. - ANS ✓18 (9014) - The thermocouple fire-
warning system is activated by a


A- parallel with each other and in series with the light. - ANS ✓19 (9015) -
When used in fire-detection systems having a single indicator light, thermal
switches are wired in


B- halogenated hydrocarbons and nitrogen - ANS ✓20 (9016) - Built-in
aircraft fire-extinguishing systems are ordinarily charged with




1
AMT Airframe

,AMT

B- both No. 1 and No. 2 are true. - ANS ✓21 (9017) - In reference to aircraft
fire-extinguishing systems,(1) during removal or installation, the terminals of
discharge cartridges should be grounded or shorted.(2) before connecting
cartridge terminals to the electrical system, the system should be checked with a
voltmeter to see that no voltage exists at the terminal connections.Regarding the
above statements,


B- A rupture of the red plastic disk in the thermal discharge line. - ANS ✓22
(9018) - What method is used to detect the thermal discharge of a built-in fire-
extinguisher system?


B- parallel with each other, but in series with the indicator lights. - ANS ✓23
(9019) - The thermal switches of a bimetallic thermal-switch type fire-detection
(single-loop) system are heat-sensitive units that complete circuits at a certain
temperature. They are connected in


C- 45 to 73°F. - ANS ✓24 (9020) - (Refer to Figure 21.) Using the chart,
determine the temperature range for a fire-extinguishing agent storage container
with a pressure of 330 PSIG. (Consider 330 PSIG for both minimum and
maximum pressure.)


A- 215 to 302 PSIG. - ANS ✓25 (9021) - (Refer to Figure 21.) Determine what
pressure is acceptable for a fire extinguisher when the surrounding area
temperature is 33°F. (Rounded to the nearest whole number.)


B- Replace the extinguisher container. - ANS ✓26 (9022) - On a periodic check
of fire-extinguisher containers, the pressure was not between minimum and
maximum limits. What procedure should be followed?


C- yellow disk on the side of the fuselage. - ANS ✓27 (9023) - In some fire-
extinguishing systems, evidence that the system has been intentionally
discharged is indicated by the absence of a


B- used only on the original discharge valve assembly. - ANS ✓28 (9024) - If
a fire extinguisher cartridge is removed from a discharge valve, it should be

2
AMT Airframe

,AMT



C- 1, 2, 3, and 4. - ANS ✓29 (9025) - Which of the following are fire precautions
which must be observed when working on an oxygen system?1. Display 'No
Smoking' placards2. Provide adequate fire-fighting equipment.3. Keep all tools
and oxygen servicing equipment free from oil or grease.4. Avoid checking aircraft
radio or electrical systems.


B- Bromotrifluoromethane (Halon 1301). - ANS ✓30 (9026) - Which fire-
extinguishing agent is considered to be the least toxic


C- replacement of damaged sensing elements. - ANS ✓31 (9027) -
Maintenance of fire-detection systems includes the


B- device for causing the fire-extinguishing agent to be released. - ANS ✓32
(9028) - A squib, as used in a fire-protection system, is a


A- remove all paint from the area to be covered by the deicer boot. - ANS ✓1
(8969) - Prior to installation of a pneumatic surface-bonded type deicer boots, on
the leading edge of the wing, you should


C- 1, 2, 3, 5. - ANS ✓2 (8970) - Which of the following are found in a laminated
integral electrically heated windshield system?1. Autotransformer.2. Heat control
relay.3. Heat control toggle switch.4. 24V dc power supply.5. Indicating light.


A- Ammeter reading. - ANS ✓3 (8971) - What is one check for proper operation
of a pitot/static tube heater after replacement?


C- Distributor valve. - ANS ✓4 (8972) - What controls the inflation sequence in
a pneumatic deicer boot system?


A- Vane-type pump. - ANS ✓5 (8973) - What is the source of pressure for
inflating deicer boots on reciprocating engine aircraft?



3
AMT Airframe

, AMT

C- Suction relief valve. - ANS ✓6 (8974) - Which of the following regulates the
vacuum of the air pump to hold the deicing boots deflated when the pneumatic
deicing system is off?


C- Soap and water. - ANS ✓7 (8975) - What may be used to clean deicer boots?


C- Whenever icing conditions are first encountered or expected to occur. -
ANS ✓8 (8976) - Some aircraft are protected against airframe icing by heating
the leading edges of the airfoils and intake ducts. When is this type of anti-ice
system usually operated during flight?


B- Fluctuating readings on the pressure gauge and relatively steady
readings on the vacuum gauge. - ANS ✓9 (8977) - Which of the following
indications occur during a normal operational check of a pneumatic deicer
system?


A- Thermo-cycling switches. - ANS ✓10 (8978) - What method is usually
employed to control the temperature of an anti-icing system using surface
combustion heaters?


B- To sequence the deicer boots inflations symmetrically. - ANS ✓11 (8979)
- What is the purpose of the distributor valve in a deicing system utilizing deicer
boots?


A- To protect the deicer boots from oil deterioration. - ANS ✓12 (8980) -
What is the purpose of the oil separator in the pneumatic deicing system?


A- Imbedded in the glass. - ANS ✓13 (8981) - Where are the heat sensors
located on most aircraft with electrically heated windshields?


B- compressor bleed air and aircraft electrical system. - ANS ✓14 (8982) -
Two possible sources of heat for the operation of a wing thermal anti-icing
system are


4
AMT Airframe

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller ExamitorMagnus. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $15.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

81989 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$15.99
  • (0)
  Add to cart