3rd Class Stationary Steam Engineer License Prep 2024/2025 Latest Questions And Answers
530 keer bekeken 1 keer verkocht
Vak
3rd Class Stationary Steam Engineer License
Instelling
3rd Class Stationary Steam Engineer License
_________ are necessary for complete combustion - Correct Answer-time, temperature, mixture, and atomization
if the steam pressure gauge indicates 200 PSIG, the absolute pressure is______ - Correct Answer-214.7
a boiler is operating at 400 PSI, and the safety valve opens at 410 PSI and closes...
3rd Class Stationary
Steam Engineer
License Prep
2024/2025
Latest Questions And
Answers
pg. 1 professoraxe l
,_________ are necessary for complete combustion - Correct
Answer-time, temperature, mixture, and atomization
if the steam pressure gauge indicates 200 PSIG, the absolute
pressure is______ - Correct Answer-214.7
a boiler is operating at 400 PSI, and the safety valve opens at
410 PSI and closes at 398 PSI. The blowdown is______psi -
Correct Answer-12
an oil cooler is commonly used with a(n) ________ when
operating in conjunction with a turbo-generator - Correct
Answer-steam turbine
a boiler is producing 40,000lb of steam/hr at a pressure of 100
PSI and a steam temperature of 500 degrees Fahrenheit. The
steam produced is _______ steam - Correct Answer-
superheated
pg. 2 professoraxe l
,the economizer on a boiler is used to _______ - Correct
Answer-add heat to the feed water
blowers are normally used with________ boilers - Correct
Answer-water tube
overheating of tubes on a boiler can be caused by________ -
Correct Answer-scale on tubes
carbon dioxide in a condensate return system
causes_________ - Correct Answer-channeling
a ________ pump is a positive displacement pump - Correct
Answer-reciprocating
a boiler generating 6000 lb of steam/hr produces
_______btu/hr - Correct Answer-6,000,000
a bottom blowdown is performed on a boiler to _____ -
Correct Answer-discharge sludge and sediment
pg. 3 professoraxe l
, water columns are connected to the boiler with a minimum of
_______" pipe - Correct Answer-1
the minimum size of a water column blowdown valve
is_______". - Correct Answer-3/4
the maximum size bottom blowdown valve on a boiler
is_________". - Correct Answer-2 1/2
a ________ allows condensate to pass through, but stops
Steam. - Correct Answer-a steam trap
when taking over a shift, the first thing to do is check
the________ - Correct Answer-water level in each boiler
according to the asme code, a high-pressure boiler having
more than 500 square feet of heating surface shall
have________ - Correct Answer-two or more safety valves
the probable cause of an increase in temperature of gases of
combustion at the boiler Outlet is____ - Correct Answer-dirty
heating services
pg. 4 professoraxe l
Voordelen van het kopen van samenvattingen bij Stuvia op een rij:
√ Verzekerd van kwaliteit door reviews
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Snel en makkelijk kopen
Je betaalt supersnel en eenmalig met iDeal, Bancontact of creditcard voor de samenvatting. Zonder lidmaatschap.
Focus op de essentie
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Veelgestelde vragen
Wat krijg ik als ik dit document koop?
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Tevredenheidsgarantie: hoe werkt dat?
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Van wie koop ik deze samenvatting?
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper PatrickHaller. Stuvia faciliteert de betaling aan de verkoper.
Zit ik meteen vast aan een abonnement?
Nee, je koopt alleen deze samenvatting voor $13.49. Je zit daarna nergens aan vast.