100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada
logo-home
MASSACHUSETTS OIL BURNER EXAM 2024 ACTUAL EXAM AND PRACTICE QUESTIONS EXAM COMPLETE ACCURATE EXAM QUESTIONS WITH DETAILED VERIFIED ANSWERS (100% CORRECT ANSWERS)/ALREADY GRADED A+ $22.99
Añadir al carrito

Examen

MASSACHUSETTS OIL BURNER EXAM 2024 ACTUAL EXAM AND PRACTICE QUESTIONS EXAM COMPLETE ACCURATE EXAM QUESTIONS WITH DETAILED VERIFIED ANSWERS (100% CORRECT ANSWERS)/ALREADY GRADED A+

1 revisar
 3 veces vendidas
  • Grado
  • MASSACHUSETTS OIL BURNER
  • Institución
  • MASSACHUSETTS OIL BURNER

MASSACHUSETTS OIL BURNER EXAM 2024 ACTUAL EXAM AND PRACTICE QUESTIONS EXAM COMPLETE ACCURATE EXAM QUESTIONS WITH DETAILED VERIFIED ANSWERS (100% CORRECT ANSWERS)/ALREADY GRADED A+

Vista previa 2 fuera de 10  páginas

  • 13 de octubre de 2024
  • 10
  • 2024/2025
  • Examen
  • Preguntas y respuestas
  • MASSACHUSETTS OIL BURNER
  • MASSACHUSETTS OIL BURNER

1  revisar

review-writer-avatar

Por: Studyplug • 5 días hace

avatar-seller
CodedNurse
10/13/24, 6:22 PM MASSACHUSETTS OIL BURNER EXAM 2024 ACTUAL EXAM AND PRACTICE QUESTIONS EXAM COMPLETE ACCURA…




MASSACHUSETTS OIL BURNER EXAM 2024
ACTUAL EXAM AND PRACTICE QUESTIONS
EXAM COMPLETE ACCURATE EXAM
QUESTIONS WITH DETAILED VERIFIED
ANSWERS (100% CORRECT
ANSWERS)/ALREADY GRADED A+


Terms in this set (193)


What is the voltage found 24 volts
at the TT terminals

1 talk to customer 2 check tt.3 check to make sure an
emergency switch is on 4check to make sure there is
oil in the tank 5 check to make sure the main power
What are the 8 steps of a going to the unit is on six check to make sure that
no heat call tank shut off valve is open 7 know whether the tank
is located above or below the burner I know the
type and style of the system that is being used on a
one or two pipe system

A device containing condominium sulfide used to
What is a cad cell
prove the flame in oil burner furnace

How much air is needed In 2015 most oil burners are set up to burn with
to burn a gallon of approximately 50% excess air because it would be
number 2 fuel oil and dangerous to set up a burner for exactly the correct
why. amount of air

What is the term InStep The stack relay is operating correctly
mean

What is normal pump 100 PSI
pressure



https://quizlet.com/956478278/massachusetts-oil-burner-exam-2024-actual-exam-and-practice-questions-exam-complete-accurate-exam-questi… 1/10

, 10/13/24, 6:22 PM MASSACHUSETTS OIL BURNER EXAM 2024 ACTUAL EXAM AND PRACTICE QUESTIONS EXAM COMPLETE ACCURA…

How is combustion Atomization, air, ignition.
achieved

Primary air, air that is introduced to a furnace burner
before the combustion process has taken place.
What is primary air and
secondary air, air that is introduced to the furnace
secondary air
after combustion has taken place and that supports
combustion

How should an oil tank It shall be secured attached to a non-combustible
be supported supports

What is the wire gauge 14 gauge 15 amp fuse
use an oil burner circuits

Shall be wired on its own circuit. All protective
control and emergency devices shall be series
How is an oil burner
connected in the grounded line conductors. all the
wired
electrical wiring shall be in accordance with 527
CMR 12.00 Massachusetts electrical code

What size vent pipe is A fill pipe shall not be greater than the vent pipe.
required with a 2 inch fill The minimum the fill pipe in the state of
pipe Massachusetts is one and one quarter inch.

Explain interrupted the ignition Transformer drops out of the circuit
ignition once a flame is established

What are the elements Carbon hydrogen oxygen and hydrocarbons
are found in fuel oil
number 2

A British thermal unit is the amount of heat needed
What is a BTU
to raise one pound of water 1 degree Fahrenheit

How many BTUs are in 140,000 BTUs
one gallon number 2 fuel
oil

What determines the Manufacturer ,the bore size, pump pressure or
gallons per hour of a Orphus
nozzle

an electrical or piping circuit where all of the
What is a series circuit
current or fluid flows through the entire circuit


https://quizlet.com/956478278/massachusetts-oil-burner-exam-2024-actual-exam-and-practice-questions-exam-complete-accurate-exam-questi… 2/10

Los beneficios de comprar resúmenes en Stuvia estan en línea:

Garantiza la calidad de los comentarios

Garantiza la calidad de los comentarios

Compradores de Stuvia evaluaron más de 700.000 resúmenes. Así estas seguro que compras los mejores documentos!

Compra fácil y rápido

Compra fácil y rápido

Puedes pagar rápidamente y en una vez con iDeal, tarjeta de crédito o con tu crédito de Stuvia. Sin tener que hacerte miembro.

Enfócate en lo más importante

Enfócate en lo más importante

Tus compañeros escriben los resúmenes. Por eso tienes la seguridad que tienes un resumen actual y confiable. Así llegas a la conclusión rapidamente!

Preguntas frecuentes

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

100% de satisfacción garantizada: ¿Cómo funciona?

Nuestra garantía de satisfacción le asegura que siempre encontrará un documento de estudio a tu medida. Tu rellenas un formulario y nuestro equipo de atención al cliente se encarga del resto.

Who am I buying this summary from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller CodedNurse. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy this summary for $22.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

45,681 summaries were sold in the last 30 days

Founded in 2010, the go-to place to buy summaries for 15 years now

Empieza a vender
$22.99  3x  vendido
  • (1)
Añadir al carrito
Añadido