100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten
logo-home
Oil Burner License Exam Questions and Answers (Already Graded A+) $16.99
In winkelwagen

Tentamen (uitwerkingen)

Oil Burner License Exam Questions and Answers (Already Graded A+)

 0 keer verkocht
  • Vak
  • Oil Burner License
  • Instelling
  • Oil Burner License

Oil Burner License Exam Questions and Answers (Already Graded A+)Oil Burner License Exam Questions and Answers (Already Graded A+)Oil Burner License Exam Questions and Answers (Already Graded A+)Oil Burner License Exam Questions and Answers (Already Graded A+) What is the first thing a tech should...

[Meer zien]

Voorbeeld 4 van de 43  pagina's

  • 14 oktober 2024
  • 43
  • 2024/2025
  • Tentamen (uitwerkingen)
  • Vragen en antwoorden
  • Oil Burner License
  • Oil Burner License
avatar-seller
NursingTutor1
Oil Burner License Exam

Questions and Answers (Already

Graded A+)


What is the first thing a tech should do when arriving at a no combustion

call? - ANSWER-Ask how many times the customer reset the unit.




What is the best long term solution for preventing a clogged nozzle? -

ANSWER--Remove any underground storage tanks.

-Install a quality oil filter.

-Cut the suction line 10" above the tank outlet to prevent sludge.




Hot water and steam valves are interchangeable. - ANSWER-False




When in the presence of a flame, a cad cell normally reads.. - ANSWER-300-

1000 ohms

,If a pump is used to bring oil to a level higher than the tank, an oil safety

valve is required. - ANSWER-True




On a call where a hydronic heat system is putting out too much heat on the

stack, the issue may be.. - ANSWER--Too much draft.

-Not enough combustion air in the equipment room.

-Air leakage into chamber.




A high CO2 reading is caused by.. - ANSWER-Incomplete combustion




An often overlooked cause of a high CO2 reading is.. - ANSWER-Not enough

combustion air in the equipment room.




When multiple pumps are wired together in a heating system, they should be

wired in.. - ANSWER-parallel




In a series circuit.. - ANSWER-Current has one path.




When 2 burners are connected to the same chimney.. - ANSWER-Sufficient

draft must be obtained to operate both units.

,The ignition transformer is located.. - ANSWER-In the primary control.




Fuel units are generally set at the factory at: - ANSWER-100 psi




The oil burner nozzle in a high pressure burner performs the following

functions: - ANSWER--Atomizes the oil

-Provides a pattern of oil spray

-Delivers a fixed amount of oil




The nozzle flow rate, spray angle and pattern are directly related to: -

ANSWER--Tangential slots

-Swirl chamber

-Orifice




Cold oil or high viscosity problems may be eliminated by: - ANSWER--

Increasing the pump pressure and reducing the nozzle size

-Installing a nozzle line pre-heater

, When safeties are wired in series one safety will affect the operation of the

others. - ANSWER-True




A stack switch is no longer allowed to be installed or replaced because.. -

ANSWER-It's safety cutout time is higher than what is now required.




What is a power venter and what does it do? - ANSWER-An electrical device

that sends fluid gases into the chimney connector.




A burner in a confined space using 1 GPH of #2 fuel oil requires what size

permanent opening for combustion air? - ANSWER-140"




The difference between an adjustable flame retention burner and a fixed

flame retention burner is? - ANSWER-Air inlets can be adjusted




Ignitor position can be adjusted




Fuel can be adjusted

Dit zijn jouw voordelen als je samenvattingen koopt bij Stuvia:

Bewezen kwaliteit door reviews

Bewezen kwaliteit door reviews

Studenten hebben al meer dan 850.000 samenvattingen beoordeeld. Zo weet jij zeker dat je de beste keuze maakt!

In een paar klikken geregeld

In een paar klikken geregeld

Geen gedoe — betaal gewoon eenmalig met iDeal, creditcard of je Stuvia-tegoed en je bent klaar. Geen abonnement nodig.

Direct to-the-point

Direct to-the-point

Studenten maken samenvattingen voor studenten. Dat betekent: actuele inhoud waar jij écht wat aan hebt. Geen overbodige details!

Veelgestelde vragen

Wat krijg ik als ik dit document koop?

Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.

Tevredenheidsgarantie: hoe werkt dat?

Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.

Van wie koop ik deze samenvatting?

Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper NursingTutor1. Stuvia faciliteert de betaling aan de verkoper.

Zit ik meteen vast aan een abonnement?

Nee, je koopt alleen deze samenvatting voor $16.99. Je zit daarna nergens aan vast.

Is Stuvia te vertrouwen?

4,6 sterren op Google & Trustpilot (+1000 reviews)

Afgelopen 30 dagen zijn er 69052 samenvattingen verkocht

Opgericht in 2010, al 15 jaar dé plek om samenvattingen te kopen

Begin nu gratis
$16.99
  • (0)
In winkelwagen
Toegevoegd