Tamper-resistant receptacles are not required in ___. - answer correctional facilities

A plug with a two-foot-long cord is permitted for a ___. - answer waste disposer

Plug-in-type overcurrent protection devices or plug-in type main lug assemblies that are
___ and used to terminate field-installed ungrounded supply conductors shall be
secured in place by an additional fastener that requires other than a pull to release the
device from the mounting means on the panel. - answerback fed

Panelboards equipped with snap switches rated ___ amperes or less shall have
overcurrent protection of 200 amperes or less. - answer30

The minumum clearance between a surface mounted fluorescent luminaire installed on
the wall above the door and the nearest point of a storage space in a clothes closet is
___. - answer6 inches

A recessed luminaire that is not identified for contact with insulation shall have all
recessed parts spaced not less than ___ from combustible materials. - answer1/2"

In which location is lighting track permitted? - answer4 feet above the floor operating on
24 volts.

A snap switch shall not be grouped or ganged in enclosures with other snap switches,
receptacles or similiar devices, unless they are arranged so that the voltage between
adjacent devices does not exceed ___, or unless they are installed in enclosures
equipped with identified, securely installed barriers between adjacent devices. -
answer300 volts

Three-way and four-way switches shall be wired so that all switching is done only in the
___ conductors. - answerungrounded

In general, flexible cords are not permitted in which application? - answerattached to
building surfaces

What is the allowable ampacity for 18 AWG fixture wire? - answer6 amperes

A non-grounding-type receptacle(s) shall be permitted to be replaced with a ground-fault
interupter-type of receptacle(s). These receptacles or their cover plates shall be marked
___. - answerCaution: No Grounding Means (correct would be No equipment means
being checked)

, Typical building construction utilizes concrete for ___ and foundations. - answerall of
these

Cement is a principal ingredient of concrete. Allowing wet concrete to touch your skin is
___. - answerhazardous

If you are working with wet cement products, you must wear ___. - answerI, II and III

When pieces of rebar protrude from concrete, these must be guarded to prevent
workers from being impaled upon them. Acceptable methods of guarding include
capping the rebar with ___. - answerlarge orange caps with steel inserts

You should not use scaffolding erected by other trades unless it has been inspected by
a competent person. - answerTrue

Working around concrete mixer trucks can be dangerous when ___. - answereither a or
b

When sizing the branch-circuit short-circuit and ground-fault protection for a three-phase
AC motor, you would use Table ___. - answer430.250

Conductors that supply a single motor used in a continuous duty application shall have
an ampacity of ___% of the motor FLA. - answer125

The conductors for a 30-minute-rated motor, used for intermittent duty, are permited to
have a rating ___% of the motor nameplate current rating. - answer90

For a hermetic refrigerant motor-compressor, the ampere rating of the disconnect shall
be ___% of the nameplate rating or the branch circuit selection current, whichever is
greater. - answer115

Overcurrent protection for generators is found in ___. - answer445.12

The walls and roofs of transformer vaults shall have a fire rating of ___ hours. - answer3

The minimum height of the door sill for a transformer vault is ___ inches. -
answer(wrong)

For one-family or two-family dwellings, a disconnecting means or its remote control for a
stationary battery system shall be located at a(n) ___ location outside the building. -
answerreadily accessible

A non-permit confined space does not contain any hazard capable of causing ___. -
answereither I or II

Written for

Institution
IEC
Course
IEC

Document information

Uploaded on
October 16, 2024
Number of pages
7
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
julianah420 Phoenix University
View profile
Follow You need to be logged in order to follow users or courses
Sold
681
Member since
3 year
Number of followers
328
Documents
35027
Last sold
5 days ago
NURSING,TESTBANKS,ASSIGNMENT,AQA AND ALL REVISION MATERIALS

On this page, you find all documents, package deals, and flashcards offered by seller julianah420

4.2

154 reviews

5
102
4
21
3
10
2
5
1
16

Trending documents

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions