, 14) Corbels should not exceed ______ of the individual masonry unit
height; nor ________ its thickness - ANSWER 1/2, 1/3
15) Smoke chamber walls should be the ______ of the firebox? -
ANSWER full width
16) Natural draft chimneys shall extend a MINIMUM of ______ ft above
any parapet wall within 10 feet - ANSWER 2 feet
17) Rectangular chimney liners with an aspect ratio greater than 2 to 1
are sized to AT LEAST _______ the fireplace opening - ANSWER 1/8
18) A level 2 inspection includes all aspects of level 1 - TRUE or FALSE? -
ANSWER TRUE
19) How far must a chimney extend above the roofline? - ANSWER
3 Feet (and at least 2ft taller than anything within 10ft)
Gaps between firestopping and the chimney shall not exceed: -
ANSWER 1/16"
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller EWLindy. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $11.34. You're not tied to anything after your purchase.