FANUC Certification Study with Questions and Accurate Answers
FANUC Certification Study with Questions and Accurate Answers T/F: Dual Check Safety position/Speed features do not need additional external sensors to monitor speed and position ANSWER True What is the correct way to recover from a DCS Joint Position Check alarm? ANSWER Press SHIFT + RESET and then jog away from the limit. Which of the following allows you to enable DCS Cartesian Speed Check? ANSWER *Program instruction *Setting on the DCS Cartesian Speed Check menu *System Variable setting **All of the above** The DCS OPSFTY signals are hardwired to which unit on the R-30iB Controller? ANSWER Emergency Stop Board There are two levels of DCS Code numbers Master and Local. The Local are...? ANSWER Base, Position/Speed Check, and I/O Connect If updated in Non-DCS menus, what does not need to be applied to the DCS Parameter? Hint: Consider ALL possible setup situations ANSWER Axis limits The maximum number of Cartesian Position Check Zones? ANSWER 32 If creating a model for your tooling what is the maximum number of shape elements that can be used? ANSWER 10