The minimum size equipment grounding conductor for a 100 ampere, 120/240 volt single phase underground dwelling feeder whose ungrounded conductors have been increased in size from 3 AWG copper to 1 AWG copper is __ AWG copper
Ampacities, Grounding
250.122(B) Table 250.122 Table 8 Ch 9 - ANSWE...
Residential Wireman Electrical Exam - Larry
Bobo(GRADED A)
The minimum size equipment grounding conductor for a 100 ampere, 120/240 volt single phase
underground dwelling feeder whose ungrounded conductors have been increased in size from 3 AWG
copper to 1 AWG copper is __ AWG copper
Ampacities, Grounding
250.122(B) Table 250.122 Table 8 Ch 9 - ANSWER 4
The continuity of the grounded conductor shall depend on a busbar or __ only.
Continuity, Grounded conductors
200.12 - ANSWER wire.
Each multi-wire branch circuit shall be provided with a means that will ____ disconnect all ungrounded
conductors at the point where the branch circuit originates.
Balconies, decks, and porches that are accessible from the inside of the dwelling unit shall have at least
one receptacle not more than __ ft. above the balcony, deck, or porch surface.
Balconies, outdoor, receptacles for,
210.52(E)(3) - ANSWER 6 1/2
Where it is impracticable to locate the service head above the point of attachment, the service head
location shall be permitted not farther than ___ inches from the point of attachment.
Service drops, Connections, service head
230.54 (C) Exception - ANSWER 24
, True/False: One of the means by which grounding conductors and bonding jumpers shall NOT be
connected by is machine screw type fasteners.
Connection of Grounding and Bonding Equipment 250.8 - ANSWER False
Cables with entirely nonmetallic sheaths are permitted to enter the top of a surface-mounted enclosure
through one or more nonflexible raceways not less than 450 mm (18 in.) and not more than __ feet in
length
Cabinets, Cutout Boxes, and Meter Socket Enclosures. 312.5(C) - ANSWER 10
The maximum allowable overcurrent protection for four 14/2 NM cables installed in contact with
thermal insulation without maintaining spacing between cables is:
Nonmetallic-sheathed cable, Insulation, Ampacity,
334.112, 334.80 - ANSWER 15
What kind of protection is required for an outdoor receptacle located under the soffit of a dwelling for
holiday lighting?
The minimum rating for a service disconnecting means for a building, other than a single family dwelling,
consisting of three 2 wire circuits shall be__ amperes.
Service equipment, Rating,
230.79(D) - ANSWER 60
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller shantelleG. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $12.99. You're not tied to anything after your purchase.