100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
Previously searched by you
EVITP: LOAD CALCULATION FEEDERS AND SERVICES LEVEL 4 MODULE 1|EVITP ACTUAL FINAL EXAM|LATEST UPDATE |BRAND NEW EXAM QUESTIONS AND CORRECT ANSWERS ALL GRADED A+|GUARANTEED SUCCESS.$13.49
Add to cart
EVITP: LOAD CALCULATION FEEDERS AND SERVICES LEVEL
EVITP: LOAD CALCULATION FEEDERS AND SERVICES LEVEL
Exam (elaborations)
EVITP: LOAD CALCULATION FEEDERS AND SERVICES LEVEL 4 MODULE 1|EVITP ACTUAL FINAL EXAM|LATEST UPDATE |BRAND NEW EXAM QUESTIONS AND CORRECT ANSWERS ALL GRADED A+|GUARANTEED SUCCESS.
9 views 0 purchase
Course
EVITP: LOAD CALCULATION FEEDERS AND SERVICES LEVEL
Institution
EVITP: LOAD CALCULATION FEEDERS AND SERVICES LEVEL
EVITP: LOAD CALCULATION FEEDERS AND SERVICES LEVEL 4 MODULE 1|EVITP ACTUAL FINAL EXAM|LATEST UPDATE |BRAND NEW EXAM QUESTIONS AND CORRECT ANSWERS ALL GRADED A+|GUARANTEED SUCCESS.
What is the demand factor allowed by the NEC® for calculating the neutral conductor size for electric range loa...
EVITP: LOAD CALCULATION FEEDERS AND
SERVICES LEVEL 4 MODULE 1|EVITP ACTUAL FINAL
EXAM|LATEST UPDATE 2024-2025|BRAND NEW
EXAM QUESTIONS AND CORRECT ANSWERS ALL
GRADED A+|GUARANTEED SUCCESS.
What is the demand factor allowed by the NEC® for calculating the neutral
conductor size for electric range load? - ANSWER-✅70%
Using the VA/linear foot method, the total VA that must be used in a service
calculation for a 50' show window is - ANSWER-✅12,500VA
Before it is considered a continuous load, a load must operate for at least how many
hours without interruption? - ANSWER-✅3
Which of the following factors does not affect conductor ampacity adjustments? -
ANSWER-✅Number of phase
If a continuous connected load totals 120A, what is the minimum current-carrying
capacity required for the feeder? - ANSWER-✅150A
What is the load center length for a tapped feeder with loads of 120A at 50', 110A at
60', 75A at 90', and 70A at 150'? - ANSWER-✅79.60
Which of the following lighting loads would be used in a residence that is 1,650 sq ft?
- ANSWER-✅4,950VA
What is the load for 40 non-dwelling unit receptacles? (Assume that the load is not
continuous.) - ANSWER-✅7,200VA
The minimum service rating for a residential service is - ANSWER-✅100A
Residential small appliance circuit must be rated at - ANSWER-✅1,500VA
Use of the 100' tap rule is limited to installation in high-bay manufacturing buildings
with wall heignt over - ANSWER-✅35 feet
Which part of a residential lighting and small appliance load must be rated at 35%
for service calculations? - ANSWER-✅The next 177,000VA
, If a store lighting load is 14,000VA (continuous), which of the following must be
used for the circuit calculation? - ANSWER-✅17,500VA
In most cases, feeder conductor size is adjusted when - ANSWER-✅there are more
than three current-carrying conductors in the raceway
When calculating the service requirement for a particular building, the step is to -
ANSWER-✅determine the floor area of the building
What is the feeder ampacity for a three-phase, 120/208V subpanel with a
connected load of 84,563VA? - ANSWER-✅235A
Which part of a residential lighting and small appliance load must be rated at 35%
for servives - ANSWER-✅
An optional method for determining feeder to schools is covered in - ANSWER-
✅NEC® Section 220.86
Refer to the figure above. What is the total load of a feeder serving four 230V
motors rated 5hp, 15hp, 20hp, and 40hp? - ANSWER-✅241.2
Refer to the figure above. Calculate the minimum ampacity for a feeder serving the
following 460V motor: 10hp, 20hp, and 30hp. - ANSWER-✅91A
Refer to the figure above. What is the total load a feeder serving four 2hp motors,
three 5hp motors, one 15hp motor, and one 25 hp motor? All motors are 208V. -
ANSWER-✅219.8 A
NEC Section ——————-permits an alternative method for calculating loads in
multi-family dwelling. - ANSWER-✅220.84
The smallest size locking and grounding type receptacle that may be used to provide
shore power for boats is - ANSWER-✅30A
33. When the over current protection for a conductor is located on the load end
rather than the supply side of a conductor it is considered to be on - ANSWER-✅Tap
conductor
farm has three buildings with loads of 85.3A, 55A, and 30A. How many amps of the
load will be subject to a 50% demand factor? - ANSWER-✅60A
The interior lighting load for a school building with 175,000 square feet of floor
space is - ANSWER-✅525,000VA
The rules governing the design of circuit supplying power to boats is covered in -
ANSWER-✅NEC® Article 555
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller BRILLIANTSOLUTIONS. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $13.49. You're not tied to anything after your purchase.