When required clearance from the lowest portion of a floor furnace to the ground cannot be
obtained, the Correct Ans-32 B 602.2 Ex (1)
ground below and to the sides shall be excavated to form a _____ pit under the furnace.(A)
rectangular (C) 45-degree sloped(B) rounded (D) basin-like. Correct Ans-33 C 802.5.5.1
... Correct Ans-34 A 212.0
Floor furnaces shall be protected, where necessary, against _____.(A) severe wind conditions (C)
damage by mechanical means(B) contact with fire-rated material (D) contact with
noncombustible material Correct Ans-35 D 205.0
... Correct Ans-36 A 225.0
Sediment traps in fuel-gas lines are not required to _____.A) hydronic boilers (C) residential
furnaces(B) gas fireplaces (D) commercial furnaces. Correct Ans-37 A 911.6(B)
... Correct Ans-38 B 912.8
Condensate from air-cooling coils and the overflow from evaporative coolers shall be collected
and Correct Ans-39 C 304.1.2,
discharged to a(an) _____.(A) public way (C) approved plumbing fixture or disposal area(B)
plumbing fixture (D) storm sewer. Correct Ans-904.10.2
, ... Correct Ans-40 B Table 3-2
Front clearance to a furnace or boiler shall be _____.(A) minimum 6 inches to combustibles(B)
minimum 6 inches to a door or an obstruction(C) minimum 9 inches to combustibles(D)
sufficient for servicing the burner and the furnace or boiler Correct Ans-41 D 912.7
... Correct Ans-42 A 912.10
Where a furnace plenum is not supplied with the furnace, the fabrication and installation shall
_____.(A) be no smaller than the outlet/inlet plenum collar(B) follow manufacturer's
instructions(C) be in a workman-like manner(D) not interfere with electrical wiring. Correct
Ans-43 B 1313.7
... Correct Ans-44 C 309.1
Wall-type room heaters shall not be attached to walls of combustible material unless _____.(A)
approved by Authority Having Jurisdiction(B) opening lined with non-combustible material(C)
listed for such installations(D) approved by the fire marshal Correct Ans-45 D 904.2(E)
... Correct Ans-46 B 903.5,
An unlisted pool heater shall be installed with a minimum clearance of _____ inches on all sides
and the rear.(A) 24 (C) 6(B) 18 (D) 12 Correct Ans-904.7(C)
... Correct Ans-47 C 924.4
Relief valves shall be piped to discharge _____.(A) near the floor (C) 6 feet above the floor(B)
above the roof (D) 6 feet from a window or door Correct Ans-48 D 922.2(C)
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller TheeGrades. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $12.99. You're not tied to anything after your purchase.