Fire Alarm Code? - -NFPA 72
-National Electric Code? - -NFPA 70
-AHJ? - -Authority Having Jurisdiction
-Disconnecting means for fire alarm power shall be what color? - -Red
-If a combination audible visible appliance is installed, the location of the
installed appliance shall be determined by the requirements of... - -The
visible appliance
-Two resistors are connected in parallel. Resister one measures 300 ohms
and resistor two measures 300 ohms. What is their equivalent resistance? - -
150 ohms
-Fire warning equipment to be installed in residential occupancies shall
produce the audible emergency evacuation signal described in... - -ANSI
S3.41
-The minimum number of restorable fixed temperature spot type heat
detectors that must be tested during each annual test is... - -Two detectors
or more on each initiating devices circuit
-What is the color code requirement for a spot type heat detector rated at
200°F? - -White
-Unless otherwise recommended by the manufacturer's published
instructions, single and multiple station smoke alarms installed in one and
two family dwellings shall be replaced every... - -10 years from the date of
manufacture
-When testing a water level supervisory switch serving a pressure tank, a
signal shall indicate if the water level has changed from the required level
by... - -Rising or falling 3 inches
-Fire alarm cables are permitted to be strapped to conduit to support the
cable. - -False
, -Where non-powered limited wiring is installed exposed, it must be
mechanically protected within how many feet of the finished floor? - -7 feet
-According to NFPA 72 visible notification appliances for non-sleeping areas
must be mounted between — and — inches above the finished floor? - -80 &
96
-If system impairment occurs, the owner must be notified — and within —? -
-In writing & 24 hours
-Conductors returning to the fire alarm control panel from the last field
device on the circuit might indicate what type of circuit? - -Class A
-Secondary power supplies for an EVAC fire alarm system shall be capable of
operating for a minimum of — of standby followed by — of alarm. - -24 hours
and 15 minutes
-The secondary power supply for protected premises shall automatically
provide power within how many seconds when the primary power fails? - -10
seconds
-When the temperature exceeds how many degrees Fahrenheit should spot
type smoke detectors not be installed? - -Above 100°F
-Who is responsible for maintaining personal protective equipment? - -The
employee
-What does GFCI stand for? - -Ground fault circuit interrupter
-After initial installation, a fixed temperature non-restorable spot type heat
detector shall be tested after how many years? - -15
-Heat detectors should be selected to operate at least how many degrees
Fahrenheit above the maximum expected ambient temperature at the
ceiling of the protected space? - -20°F
-According to NFPA 72, testing records of the fire alarm system shall be kept
until the next test and... - -Every one year after
-Who is responsible for storing and maintaining test records for the fire
alarm system? - -Owner of the system
-Household fire alarm system smoke detectors shall be tested by a
technician how regularly? - -Annually
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller Nursephil2023. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $12.49. You're not tied to anything after your purchase.