100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Samenvatting Neural networks - deel 1 $11.40   Add to cart

Summary

Samenvatting Neural networks - deel 1

 4 views  0 purchase
  • Course
  • Institution

Course Neurological Aspects, part 1 of Neural Networks, taught by Prof. Alaerts (KUL). Part 2 (given by Prof. Gilat) is also available.

Preview 4 out of 51  pages

  • November 2, 2024
  • 51
  • 2023/2024
  • Summary
avatar-seller
NEUROLOGICAL ASPECTS:
NEURAL NETWORKS AND
REORGANIZATION
Academiejaar 2023-2024 – 2MARE




H1. NEUROSCIENTIFIC METHODS

H2. THE POTENTIAL OF NON-INVASIVE BRAIN
STIMULATION IN NEUROREHABILITATION

H3. AGEING AND NEUROPLASTICITY

H4. NEUROREHABILITATION AFTER STROKE




PART PROF. KAAT ALAERTS

, PART KAAT ALAERTS




Neurological aspects: neural networks
and reorganization
CHAPTER 1: NEUROSCIENTIFIC METHODS


• Measuring ‘brain activity’ at the systems level (not single-cell)
• Non-invasive (not ‘inside’ the brain, but at the level of the scull)
• Fundamental research
o Motor control, motor learning
o Cognition
o Memory
o ...
• Clinical research
o Neural processes underlying ageing
o Neural basis of diseases (stroke, Parkinson, epilepsy, neurodevelopmental disorders)
o Neural evaluation of disease progression
o Neural evaluation of interventions/ treatments

Look for each technique at equipment, neurophysiological basis and examples of applications




 Important concept to evaluate the advantages and disadvantages of different techniques
 Temporal and spatial resolution
o Some better for temporal: what is happening in time regarding brain activity?
o TEMPORAL = when in time
o SPATIAL = where in the brain


1/ MAGNETIC RESONANCE IMAGING (MRI)
What isn’t fMRI?
➢ fMRI is not bumpology (claims that bumps on the skull reflected exaggerated functions/traits)
➢ fMRI is not mind-reading
➢ fMRI is not invasive (the skull remains closed)
What is fMRI: a relative, safe, non-invasive technique


1

, PART KAAT ALAERTS




1.1 Equipment
- Giant magnet
- Head coil (helps with high-quality images)

MRI = brain anatomy
fMRI = functional MRI = brain activity
fcMRI = functional connectivity

First MRI-scan around 1950, first functional MRI-scan developed way later (around 1990)

1.2 Biological basis of MRI
• Measures brain anatomy
• Former name: (Nuclear) Magnetic Resonance Imaging → nothing to do with ‘radioactivity’, but
with the magnetic properties of protons, in the nuclei of atoms

Protons:
- Have a mass, are positive (+) and have a spin (they turn around)
- Because protons turn around, they have a small, but measurable magnetic field
- In everyday life, the protons in our body are in balance, randomly oriented, but in balance
- Inside the MRI scanner, which is one giant magnet, the protons align to the magnetic field (B0).
Either in parallel (same direction) or anti-parallel (opposite direction)
- Most protons will align parallel in MRI-scan
- The majority of atoms aligns in parallel, allowing to define the NET magnetization of protons
in the direction of B0
- This is what happens if you’re positioned in the scanner. And this magnetic field is ALWAYS on.




- Emission of a radio frequency pulse by the head coil, induces a flip of the NET magnetization
(instead of aligning to the Z- axis, the protons now align in the X-Y field)
- Proton is in excitation state
- Head coils will emit a radiofrequency: magnetic field of protons will shift (excitation
state) → follow the Y-axis
- However, protons don’t like being in this ‘high-energy’ excitation state’, and from the moment
the radio frequency pulse is turned off, it will ‘relax’ to its initial position (i.e., align back to the
Z-axis of the B0 field).
- During this ‘relaxation state’, the protons emit radio frequency themselves, and this signal is
measured. (The head coil, both emits and measures radio frequencies)
- Proton emits radio frequency during relaxation state
- Protons want to align with the Z-axis → when the radiofrequency is turned off, they
return to the Z-axis
- While doing this, they will emit radiofrequency itself → MRI can measure the different
relaxation times in the different tissue




2

, PART KAAT ALAERTS



The time it takes for a proton to relax to 63% of its initial state (along the z-axis) is called T1
 T1 = relaxation time

• Not all tissues ‘relax’ the same way!
• Protons in fat (e.g., white matter), relax much faster, than protons
in liquid (e.g., cerebrospinal fluid)
• By measuring the relaxation in different tissues, contrasts can be
visualized!
• In so-called ‘T1-weighted’ images, liquid is dark (less energy emitted), and fat is bright (more
energy emitted) → dark matter needs less energy at T1 compared to white matter (grey matter
is in between)
1.2.1 Examples of application
➢ Clinical: Localization of brain lesions
➢ Used in pre-surgical mapping (e.g., epilepsy) and prediction of disease progression




1.3 Functional MRI (fMRI)
 Uses MRI to indirectly measure brain activity

Same principle as MRI: contrasts in brain images based on measurement of magnetic relaxation
→ Here however, it is not about protons, but about hemoglobin in the blood...
1.3.1 Biological basis of fMRI
• Brain region active => increased O2 metabolism => increased blood flow
• fMRI measures the Blood Oxygen Level Dependent (BOLD) signal
o Oxyhemoglobin = diamagnetic (same as tissue)
o Deoxyhemoglobin = paramagnetic (weak magnetic) → interacts with the signal of MRI
• fMRI always measures a change in BOLD-response
o You always need a baseline to see how BOLD has changed
o During baseline situation, the BOLD-signal goes back down again

LEFT-LEFT = brain at rest
 Basic metabolism (good balance between oxy and de-oxy Hb in bloodstream, normal usage of
oxygen by the neuronal cells, normal glucoses dosage as energy resource)
LEFT-RIGHT = activation of the neuron
→ Neurons will require an increased metabolism of glucoses and oxygen
 Initially in bloodstream will be higher amount of de-oxy compared to oxy
→ This gives a reduced BOLD-signal
RIGHT = this triggers a haemodynamic respons rendering an increased transport of oxy to this region
of activation
 Rendering in a lowering of the ratio de-oxy/oxy → rendering in an increase of BOLD-signals



3

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller LB2001. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $11.40. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

79202 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$11.40
  • (0)
  Add to cart