NERC BI - System Operations

Disturbance - answerAny perturbation to the electric system or the unexpected change
in ACE that is caused by the sudden loss of generation or interruption of load

Interconnection reliability operating limit ( IROL) - answer The value (such as MW,
MVar, Amperes, Frequency or Volts) derived from, or a subset of the System Operating
Limits, which if exceeded, could expose a widespread area of the Bulk Electric System
to instability, uncontrolled separation(s) or cascading outages.

Interconnection reliability operating limit – answer A System Operating Limit that, if
violated, could lead to instability, uncontrolled separation, or Cascading outages4 that
adversely impact the reliability of the Bulk Electric System.

Impedance - answer The AC version of resistance to power flow, it includes inductive
and capacitive reactance ( note when lines run in parallel it lowers the path of
impedance)

Phase Angle - answer

Power Angle - answer

Voltage - answeran electromotive force or potential difference expressed in volts.

System Operating limit - answerThe value (such as MW, MVar, Amperes, Frequency or
Volts) that satisfies the most limiting of the prescribed operating criteria for a specified
system configuration to ensure operation within acceptable reliability criteria. System
Operating Limits are based upon certain operating criteria. These include, but are not
limited to:
Facility Ratings (Applicable pre- and post-Contingency equipment or facility ratings)
Transient Stability Ratings (Applicable pre- and post-Contingency Stability Limits)
Voltage Stability Ratings (Applicable pre- and post-Contingency Voltage Stability)
System Voltage Limits (Applicable pre- and post-Contingency Voltage Limits)

What is the maximum power angle degree in the power transfer equation? Greater than
this will cause system instability. - answer90 Degrees

What three elements make up impedance in an alternating current power system -
answerCapacitance inductance and resistance

Which elements make up power - answercurrent impedance and voltage

, Steady state stability - answerwhen the system parameters monitored by the reliability
coordinators, transmission operators and balancing authorities such as voltages,
frequency and power flows may be changing but the changes are small and occur
gradually

Transient stability - answerTransient stability describes the ability of the power system
where a sudden large change takes place within the system without violating system
operating limits. This could be the loss of a major generator or a severe system fault

Generators as the source of real and reactive power are the stabilizing force in the
power system

Power angle across a section of the system is ... - answer20 degrees

What happens if a transmission line outage occurs - answerMW flows increase on the
existing transmission lines still in service

As Amps increase MVAR losses as a result of existing inductive reactance -
answerIncreases

Transient instability - answerpower angle greater than 90 degrees from power transfer,
when a disturbance causes power angle greater than 90 degrees or when heavy power
transfers to one or more transmission segments such as a loss in generation

Reliability coordinator, transmission operator and balancing authority can manage
outages effectively by - answer- Coordinate and adhere to voltage schedules to
minimize reactive power flow and to minimize system transfers that require additional
VAR reserves

- Verify generator, synchronous condenser, SVC or other voltage control equipment
voltage regulators are on automatic for dynamic reactive power supply to support
voltage

- Optimize the use of load tap change (LTC) transformers, capacitor banks and reactor
(inductor) banks are due to the time lag involved in controlling these devices

Real power MW will flow on the transmission system as a result of power angle
differences. What direction will real power flow? - answerHigher power angle to lower
power angle

True or False - System stability is when there are few changes in the power system and
in the event of a disturbance the system will successfully absorb the impact and
continue within its system operating limits - answerTrue

System operators monitor real time power system data. They must be prepared and
take action to ensure equipment is operated within? - answerSystem Operating limits

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller julianah420. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $17.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

77254 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$17.99
  • (0)
  Add to cart