What is the first thing a tech should do when arriving at a no combustion call? -
ANSWER-Ask how many times the customer reset the unit.
What is the best long term solution for preventing a clogged nozzle? -
ANSWER--Remove any underground storage tanks.
-Install a quality oil filter.
-Cut the suction line 10" above the tank outlet to prevent sludge.
Hot water and steam valves are interchangeable. - ANSWER-False
When in the presence of a flame, a cad cell normally reads.. - ANSWER-300-
1000 ohms
If a pump is used to bring oil to a level higher than the tank, an oil safety valve
is required. - ANSWER-True
On a call where a hydronic heat system is putting out too much heat on the
stack, the issue may be.. - ANSWER--Too much draft.
-Not enough combustion air in the equipment room.
-Air leakage into chamber.
,A high CO2 reading is caused by.. - ANSWER-Incomplete combustion
An often overlooked cause of a high CO2 reading is.. - ANSWER-Not enough
combustion air in the equipment room.
When multiple pumps are wired together in a heating system, they should be
wired in.. - ANSWER-parallel
In a series circuit.. - ANSWER-Current has one path.
When 2 burners are connected to the same chimney.. - ANSWER-Sufficient
draft must be obtained to operate both units.
The ignition transformer is located.. - ANSWER-In the primary control.
When safeties are wired in series one safety will affect the operation of the
others. - ANSWER-True
A stack switch is no longer allowed to be installed or replaced because.. -
ANSWER-It's safety cutout time is higher than what is now required.
What is a power venter and what does it do? - ANSWER-An electrical device
that sends fluid gases into the chimney connector.
A burner in a confined space using 1 GPH of #2 fuel oil requires what size
permanent opening for combustion air? - ANSWER-140"
The difference between an adjustable flame retention burner and a fixed flame
retention burner is? - ANSWER-Air inlets can be adjusted
,Ignitor position can be adjusted
Fuel can be adjusted
Oil tank design, construction, installation and testing shall be in accordance
with.. - ANSWER-527 CMR 9.0
Heat is a form of.. - ANSWER-Energy
If a burner is operational but the circulator pump isn't running.. - ANSWER-The
pump relay is not working correctly
A method of dealing with low viscosity/cold temps with #2 oil? - ANSWER-
Increase pump pressure/ decrease nozzle size
What is needed at the outlet of an oil tank? - ANSWER-Thermal safety valve
Where do you obtain an installation permit for oil burners? - ANSWER-Fire
Dept
How many Btu's approximately in 1 gal of #2 fuel oil? - ANSWER-140,000 btu's
Solid state ignition is superior to spark because - ANSWER-It is not affected by
reduced voltage
, What is an installation? - ANSWER-The complete setting in place, ready for
operation, of an oil burner appliance together with its accessories and
equipment.
How far must a power vent terminate from an opening or window? - ANSWER-
4'
A pump in a one pipe system that is full of air can be self purged. - ANSWER-
False
List the minimum size of an oil supply line. - ANSWER-3/8"
A material with electrons so loose it allows voltage to pass with little or no
resistance.. - ANSWER-Is a conductor
If a high limit goes off, what does a low water switch do? - ANSWER-Maintains
water temperature
What is flashpoint an indicator of? - ANSWER-Minimum temperature oil will
ignite but not continue to burn.
What travels on the inside of the wire? - ANSWER-Volts
What does readily accessible mean pertaining to oil burning equipment? -
ANSWER-Capable of being reached easily and quickly for operation,
maintenance or inspection.
What is the minimum vent pipe on an oil tank? - ANSWER-1 1/4"
Les avantages d'acheter des résumés chez Stuvia:
Qualité garantie par les avis des clients
Les clients de Stuvia ont évalués plus de 700 000 résumés. C'est comme ça que vous savez que vous achetez les meilleurs documents.
L’achat facile et rapide
Vous pouvez payer rapidement avec iDeal, carte de crédit ou Stuvia-crédit pour les résumés. Il n'y a pas d'adhésion nécessaire.
Focus sur l’essentiel
Vos camarades écrivent eux-mêmes les notes d’étude, c’est pourquoi les documents sont toujours fiables et à jour. Cela garantit que vous arrivez rapidement au coeur du matériel.
Foire aux questions
Qu'est-ce que j'obtiens en achetant ce document ?
Vous obtenez un PDF, disponible immédiatement après votre achat. Le document acheté est accessible à tout moment, n'importe où et indéfiniment via votre profil.
Garantie de remboursement : comment ça marche ?
Notre garantie de satisfaction garantit que vous trouverez toujours un document d'étude qui vous convient. Vous remplissez un formulaire et notre équipe du service client s'occupe du reste.
Auprès de qui est-ce que j'achète ce résumé ?
Stuvia est une place de marché. Alors, vous n'achetez donc pas ce document chez nous, mais auprès du vendeur trustednurse. Stuvia facilite les paiements au vendeur.
Est-ce que j'aurai un abonnement?
Non, vous n'achetez ce résumé que pour $25.99. Vous n'êtes lié à rien après votre achat.