100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
Previously searched by you
IBHRE CEPS TEST FINAL EXAM 2024/2025 NEWEST ACTUAL EXAM AND PRACTICE EXAM QUESTIONS COMPLETE ACCURATE EXAM QUESTIONS WITH DETAILED VERIFIED ANSWERS (100% CORRECT ANSWER S) /ALREADY GRADED A+$15.29
Add to cart
IBHRE CEPS TEST FINAL EXAM 2024/2025 NEWEST ACTUAL EXAM AND PRACTICE EXAM QUESTIONS COMPLETE ACCURATE EXAM QUESTIONS WITH DETAILED VERIFIED ANSWERS (100% CORRECT ANSWER S) /ALREADY GRADED A+
5 views 0 purchase
Course
IBHRE CEPS
Institution
IBHRE CEPS
IBHRE CEPS TEST FINAL EXAM 2024/2025 NEWEST ACTUAL EXAM AND PRACTICE EXAM QUESTIONS COMPLETE ACCURATE EXAM QUESTIONS WITH DETAILED VERIFIED ANSWERS (100% CORRECT ANSWER S) /ALREADY GRADED A+
IBHRE CEPS TEST FINAL EXAM 2024/2025 NEWEST ACTUAL EXAM AND PRACTICE EXAM QUESTIONS
COMPLETE ACCURATE EXAM QUESTIONS WITH DETAILED VERIFIED ANSWERS (100% CORRECT
ANSWER S) /ALREADY GRADED A+
Ohm's law equation - correct answer V=IR
EKG monitored patient should be __________, monitor chassis should be ___________
(nonconductive). Why - correct answer ungrounded, grounded. Grounded patient would be
able to conduct leakage currents. we dont want this
lb to kg - correct answer 2.2 lb = 1 kg
F to C - correct answer C=5/9(F-32)
C to F - correct answer F=9/5C+32
3 things that change automaticity of automatic cells - correct answer 1. slope of phase 4
2. Change of threshold potential
3. Change of resting membrane potential
a systole is represented by what portion of the ECG - correct answer QT interval
What is main ion transfer during systole - correct answer K+ seeps out, Ca2+ enters
At rest, what is intracellular/extracellular environment - correct answer inside negative,
outside positive
What phase of AP is resting membrane potential - correct answer phase 4
Nodal depolarization occurs via what channel - correct answer Ca2+ slow channel
Cardiac muscle cell depol occurs via what channel - correct answer Na+ fast channel
During which phases is cell refractory - correct answer 1,2,3
TDP caused by what mechanism usually - correct answer EAD's (triggered activity)
Variance - correct answer Take each number in sample, subtract each number from mean,
square each difference, add all, divide sum by number in sample -1
Standard deviation - correct answer square root of variance
P value - correct answer Probability of certainty / smaller p value means the more likely the
result could not occur by chance
survival curve showing % of patients surviving treatment over time - correct answer Kaplan -
Meier curves
when measuring EGM's, earliest atrial activation usually from _____ and earliest ventricular
usually from ______ - correct answer P wave / QRS
Morady maneuver is used to differentiate - correct answer differentiate AT from AVNRT/AVRT
, IBHRE CEPS TEST FINAL EXAM 2024/2025 NEWEST ACTUAL EXAM AND PRACTICE EXAM QUESTIONS
COMPLETE ACCURATE EXAM QUESTIONS WITH DETAILED VERIFIED ANSWERS (100% CORRECT
ANSWER S) /ALREADY GRADED A+
Most common arrhythmia - correct answer AF
Most common SVT - correct answer AVNRT
What type of single use devices can be resterilized and why? - correct answer Diagnostic EP
electrodes because lumen and technically not a catheter because no lumen
Fr to mm - correct answer 1 Fr = .33 mm
Tip inner diameter standard diagnostic cardiac catheters and why - correct answer .038 inch /
because it is supposed to be used with .035-.038 inch guide wires
What is 2 rules for CMC's like spiral or lasso - correct answer 1. Only approved for use in LA
due to chordae tendinea
2. Only rotate shaft clockwise
Stereotaxis catheters - correct answer Have magnets in tip for maneuverability in response to
changes in magnetic field
What system remotely steers guided catheters - correct answer Hansen robotic system
ACT for using array - correct answer ACT 250-300
bipolar cardiac electrodes record local _________ that occur during phase _______ - correct
answer depolarizations / phase 0
surface EKG leads usually filtered at what - correct answer .1 - 100 Hz
Normal EGM filter settings - correct answer 30 - 300 Hz
What to do if T waves interfere with A/V and why - correct answer Increase the high pass filter
because T waves are lower frequency as well as far field
Unipolar filter setting - correct answer .05 - 300 Hz
How each is measured: Diagnostic catheter OD , Inflated balloon cath OD, Needle OD, Guide
wire - correct answer Diag: Fr / Balloon: mm / Needle: gauge / GW: inch (thousandth of
inches)
Standard sizes of micropuncture introducer sets and their purpose - correct answer 21 gauge
needle / .018 inch wire. Purpose of micropuncture introducer set is for placement of .035-.038
inch GW
Best needle to use for pericardial space via subxyphoid approach - correct answer Tuohy
needle
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller examsetters. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $15.29. You're not tied to anything after your purchase.