100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Backflow QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES 2025/2026 (VERIFIED ANSWERS) |ALREADY GRADED A+ $12.99   Add to cart

Exam (elaborations)

Backflow QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES 2025/2026 (VERIFIED ANSWERS) |ALREADY GRADED A+

 2 views  0 purchase
  • Course
  • BACKFLOW PREVENTION
  • Institution
  • BACKFLOW PREVENTION

Backflow QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES 2025/2026 (VERIFIED ANSWERS) |ALREADY GRADED A+

Preview 2 out of 5  pages

  • November 19, 2024
  • 5
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • backflow prevention
  • BACKFLOW PREVENTION
  • BACKFLOW PREVENTION
avatar-seller
Ashley96
Backflow

1. A 1/4" diameter potable water deliver shall have at the least a _____ air hole separation
between the deliver pipe and the flood stage rim - ANS-1 inch
2. a 2 inch atmospheric vacuum breaker set up on a 2 inch water deliver to a tank need to
be at least _______ above the flood degree rim of the tank - ANS-six inches
3. a take a look at valve in an permitted BF meeting should be drip tight while? - ANS-The
assembly is situation to any backflow
4. a chemically handled boiler device might require what sort of backflow protection on the
potable water make up line? - ANS-RP
5. A differential stress gauge is used in the trying out of? - ANS-Reduced stress and double
take a look at valve assemblies
6. A double check Assembley test and maintenance document shall consist of all the
following accept? - ANS-Differential strain comfort valve discharge reading
7. A double take a look at BFP assembly will defend the potable water deliver from? -
ANS-NON-Health hazard- Backpressure and Back siphonage
8. a leaking check valve may be caused by? - ANS-Dirty or broken check disc, take a look
at seat; broken or broken spring, or guide members putting up
9. a capability backpressure backflow plumbing connection is - ANS-manner water line
10. A stress gauge set up at the lowest of an open tank containing water 10 feet deep, might
suggest what pressure studying? - ANS-four.Three psi (atmospheric strain is .433)
11. A stress of 75 psi would be equal to what ______ head strain? - ANS-173.2 toes ( 1 foot
of head is 2.3 psi) (2.Three x 75= 173 feet)
12. A RP check will imply a leaking variety shutoff valve by way of? - ANS-No trade inside
the differential strain analyzing while checking out the differential pressure relief valve
13. A RP's differential remedy valve operates from the incoming water stress and the water
strain within the? - ANS-quarter between the 2 take a look at valves
14. a small hole in the underground potable water distribution device may additionally -
ANS-permit infection from returned-siphonage backflow
15. a spill resistant vacuum breaker is a modified - ANS-pressure vacuum breaker meeting
16. all of the following ought to create a closed loop piping device except a? - ANS-Pressure
remedy valve
17. an absolute strain of 25 PSIA is equal to - ANS-10 PSIG
18. an absolute vacuum at sea stage can raise a column of water a max distance of -
ANS-33.Nine feet
19. an air gap separation is decided from the opening piping's______ diameter -
ANS-effective
20. An air hole separation is measured from the outlet of the release pipe to the? -
ANS-Flood level rim
21. An atmospheric kind vacuum breaker shall now not be subjected to water pressure for
intervals longer than _______ Hours? - ANS-12

, 22. An atmospheric vacuum breaker is installed to protect in opposition to? -
ANS-BACKSIPHONAGE- Health threat OR Non fitness chance situations
23. An occasional discharge from the relaxation valve of a RP commonly shows? - ANS-The
device is running properly
24. an unprotected pass around a backflow prevention assembly or tool - ANS-is considered
a pass connection and is never accepted
25. Approved Reduced strain precept meeting, refers to 2 shutoff valves, four test cocks,
and? - ANS-2 accepted test valves and a Differential stress relief valve.
26. Backflow may be defined as? - ANS-Backpressure or back siphonage
27. Constant discharge from the comfort valve of a RP usually suggests? - ANS-Leaking #1
take a look at valve
28. fit to be eaten syrup brought right into a water device thru a pass-connection could be an
instance of? - ANS-A non-health risk
29. Every vacuum breaker is designed to? - ANS-save you backsiphonage backflow
30. For containment protection in a non-fitness chance state of affairs, the minimum
protection required shall be? - ANS-Double check backflow prevention assembly
31. How can you stop an occasional discharge of water from the comfort valve of a RP
caused by supply pressure fluctuations? - ANS-By putting in a soft seat take a look at
valve upstream of the assembly
32. How many inches ought to a strain kind vacuum breaker be hooked up mainly
downstream piping? - ANS-12 inches
33. How many inches ought to an Atmospheric vacuum breaker be installed in particular
downstream piping and the very best commencing? - ANS-6 inches
34. How many psi are exerted at the base of a column of water that is toes tall? - ANS-.86
35. If all through the sector check of a RP, the comfort valve fails to open, the in all likelihood
cause is? - ANS-A malfunction of the differential strain relief valve mechanism
36. if no longer marked, the crucial level of a strain vacuum breaker is believed to be the
extent of the? - ANS-backside of the valve body
37. if the air inlet valve of a stress vacuum breaker meeting will now not seat, the -
ANS-supply stress is just too low
38. If the test valve springs are interchanged on a double test valve, the assembly? -
ANS-Will not be adversely suffering from the interchange
39. It is feasible for a great vacuum at sea degree to elevate water in a pipe about? -
ANS-33.Nine or 34 Feet
40. it's far viable to catch up on a leaking range 2 shut off valve at some stage in field test of
a RP by way of attaching a brief bypass hose from? - ANS-primary test cock to variety
four take a look at cock
41. It is needed that the take a look at gauge be examined for accuracy at the least? -
ANS-Annually
42. on an approved pressure vacuum breaker, the shut off valves? - ANS-are positioned at
the inlet and outlet of all assemblies
43. Point of use backflow prevention is described as - ANS-Isolation
44. PSIG is equivalent to - ANS-PSIA minus atmospheric strain

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Ashley96. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $12.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

72042 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$12.99
  • (0)
  Add to cart