ANSWERS 100% CORRECT
Unrestricted area limits - ANSWER-2mrem/hr (.02mSv)
White 1 - ANSWER-TI = 0 Surface = .5mR/hr
Yellow 2 - ANSWER-TI = 1 Surface = 50mR/hr
Yellow 3 - ANSWER-TI = 10 Surface = 200mR/hr
3 federal regulating agencies - ANSWER-NRC, DOT, FDA
WB TEDE - ANSWER-5rem/yr (50mSv)
Lens of eyes (LDE) - ANSWER-15rem/yr (150mSv)
Organ or tissue (TEDE) - ANSWER-5rem/yr (50mSv)
Extremities/hands (SDE) - ANSWER-50rem/yr (500mSv)
General public (TEDE) - ANSWER-.1rem/yr (1mSv)
Embryo of declared pregnancy worker - ANSWER-.5rem/yr (5mSv)
Counting Efficiency Equation - ANSWER-CE = cpm/dpm
Caution: high radiation area - ANSWER-Where therapy is performed, Area where an
individual could receive >100mrem (1mSv) in 1 hour at 30cm from the source.
How long are survey and wipe records kept for? - ANSWER-3 years
Dose range for non-therapeutic doses? - ANSWER-+-20%
Removable contamination limit - ANSWER-6600dpm/300cm^2
Caution: Radioactive materials - ANSWER-Nuclear medicine labs, where radioactive
materials are used and stored.
Caution: Radiation Area - ANSWER-Entrances to nuclear medicine departments. Area
where an individual could receive >5mrem (.05mSv) in 1 hour at 30cm from the source.