100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
QUALITY CONTROL TEST QUESTIONS & ANSWERS $10.99
Add to cart

Exam (elaborations)

QUALITY CONTROL TEST QUESTIONS & ANSWERS

 2 views  0 purchase
  • Course
  • QUALITY CONTROL
  • Institution
  • QUALITY CONTROL

QUALITY CONTROL TEST QUESTIONS & ANSWERS

Preview 2 out of 5  pages

  • December 9, 2024
  • 5
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • QUALITY CONTROL
  • QUALITY CONTROL
avatar-seller
GEEKA
QUALITY CONTROL TEST QUESTIONS & ANSWERS
Which of the following is one of the objectives of a QA program in Medical Imaging? -
Answers - Ensure high quality services

QC in diagnostic imaging deals with - Answers - Equipment

SC 35 is published by - Answers - Health Canada - federal

The minimum safety & performance standards expected of all medical x-ray equipment
used in Canadian facilities are laid out by - Answers - Regulatory Acts

The associated QC procedures for medical x-ray equipment are described by - Answers
- Health Canada in the Safety Code

The exposure timer is # ______; and the kV selector is # ______. These are both
located on the ______ side of the x-ray generator circuit. - Answers - 4; 3; primary -
anything connected to control panel has to be low voltage in case of shock to the
operator

Radiation output is a measure of beam - Answers - quantity

Radiation output reproducibility and linearity must be tested - Answers - Annually

The term linearity means the radiation output will - Answers - increase sequentially with
the same sequential increase in mA, time or mAs

According to SC 35, for any ten consecutive measurements taken at the same control
panel settings within 1 hour of each other, the coefficient of variation should not exceed:
(we looked at the percent variation not the coefficient) - Answers - 0.05 (5% fluctuation
is allowed)

The mA selector is located in the - Answers - filament circuit - quantity of photons in x-
ray beam

Half-value layer (HVL) is a measure of beam - Answers - filtration

X-Ray beam filtration must be tested - Answers - Annually

Where the x-ray tube voltage is 50 kV or more, the current-time product must not
exceed - Answers - mAs per irradiation 600

The accuracy of tube loading factors must be tested - Answers - Annually - qc
technologist

, The term reproducibility means the radiation output - Answers - is consistent from one
exposure to the next - synonym is reliability

According to SC 35, for any combination of loading factors, the ______ must not deviate
from the selected value by more than _____. - Answers - i.kVp; ___10___ %. ii. time;
__10____ % + 1 ms. iii. mA; ___20___ %. iv. mAs; ____10__ % + 0.2 mAs.

The safety code specifies the _______ half-value layer of aluminum for given tube
voltages. - Answers - minimum

According to SC 35, the x-ray tube shielding must be such that the ______ radiation
from the x-ray source assembly shall not exceed an air kerma rate of ____ mGy/h at a
distance of 1 m away from the focal spot, when the tube is at maximum loading. -
Answers - leakage; 1.0

The red outline represents the - Answers - Protective housing/shielding

The life span of a storage phosphor screen (SPS) used in CR is approximately _______
exposures. - Answers - 10 000

Compared to FPD imaging, dynamic range and DQE of PSP imaging is - Answers -
lower

The light released by the stimulating laser inside the CR reader is - Answers -
monochromatic

Inside the CR reader, the IP translates along the roller mechanism in a direction that is -
Answers - perpendicular to the laser beam

Which IP size is sampled at the highest rate (greatest # of pixels/mm)? - Answers - 8x10

SC 35 recommends that a visual inspection of the physical condition of the phosphor
screen be performed - Answers - Weekly

SC 35 recommends that cleaning of the phosphor screen be performed - Answers -
Monthly

True or False: when it comes to the proper care and maintenance of the IPs and CR
reader, the manufacturers recommendations supersede SC 35 - Answers - True

If the IP is not erased sufficiently after a high exposure, and some of the phosphors still
hold their charge, the artefact that demonstrated on the subsequent image is called -
Answers - residual image artifact

Indirect Digital Radiography (i-DR) uses what type of capture element in the detector? -
Answers - Scintillator

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller GEEKA. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $10.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

56326 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$10.99
  • (0)
Add to cart
Added