100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
S12 sprinkler test, S13 standpipe test, Sprinklers segment 5, S-12 CITYWIDE all Questions & answers solved accurately with Complete Solution Graded A+ latest version CA$18.68   Add to cart

Exam (elaborations)

S12 sprinkler test, S13 standpipe test, Sprinklers segment 5, S-12 CITYWIDE all Questions & answers solved accurately with Complete Solution Graded A+ latest version

 4 views  0 purchase

S12 sprinkler test, S13 standpipe test, Sprinklers segment 5, S-12 CITYWIDE all Questions & answers solved accurately with Complete Solution Graded A+ latest version

Preview 4 out of 41  pages

  • July 6, 2024
  • 41
  • 2023/2024
  • Exam (elaborations)
  • Questions & answers
All documents for this subject (31)
avatar-seller
TUTORSON
S12 sprinkler test, S13 standpipe test,
Sprinklers segment 5, S-12 CITYWIDE
SPRINKLER SYSTEMS
fire department connection - CORRECT ANSWER-normally on exterior of
building... FDNY can pump supplemental water into the sprinkler system,
standpipe, or other system furnishing water for fire extinguishment to supplement
existing water supplies.

system control valve - CORRECT ANSWER-valve controlling flow to water-based
fire protection systems.

fire command center - CORRECT ANSWER-Designated room or area in a
structure where the status of the fire detection, alarm, and protection systems is
displayed and the systems can be manually controlled.

Fire pump, automatic standpipe. - CORRECT ANSWER-A fire pump located at
or below street level that supplies the lower 300 feet (91.4 m) of a standpipe
system or a combined standpipe and sprinkler system.

tags - CORRECT ANSWER-on closed section valves serving affected areas:
area affected, brief description, occupancy classification, c of f number, estimated
time until operational

Green tag - CORRECT ANSWER-no impairment found in entire system- main
control valve

red tag - CORRECT ANSWER-place on main control valve if FULLY out of
service... put sprinkler company name, date of removal from service and
anticipated time to operational

blue disk - CORRECT ANSWER-partially out of service- on all fire department
connections

water storage tank - CORRECT ANSWER-Collects cooled water

,OS & Y valve - CORRECT ANSWER-indicating type of control valve used for fire
sprinkler system

deluge valve - CORRECT ANSWER-water supply control valve intended to be
operated by actuation of an automatic detection system that is installed in the
same area as the discharge devices. INTENDED USE IS MANUAL AND AUTO

deluge sprinkler system - CORRECT ANSWER-employing open sprinklers that
are attached to a piping system that is connected to a water supply through a
valve that is opened by the operation of a detection system installed in the same
areas as the sprinklers. WHEN IT OPENS, water flows into the piping system
and discharges from all sprinklers attached.

Early suppresion fast response sprinklers - CORRECT ANSWER-fast response
sprinkler that is listed for its capability to provide fire suppression of specific high
challenge fire hazards

extra large orifice sprinklers - CORRECT ANSWER-= or > 1 inch less pressure to
achieve a given discharge density

extended coverage sprinkler - CORRECT ANSWER-400 max square feet
discharge 20 foot by 20 foot spacing between sprinklers

fire pump - CORRECT ANSWER-a provider of liquid flow and pressure dedicated
to fire protection. A fire pump is a part of a fire sprinklers system water supply
and can be powered by electric, diesel or steam. connected to public water
source or tank. provides higher pressure to sprinkler system

Glass bulb sprinkler - CORRECT ANSWER-operated by heat breaking a glass
bulb filled with a non freezing liquid with diameters that vary form 3 mm for quick
response to 5 mm for standard response

hose valve - CORRECT ANSWER-valve to additional hose connection

,hydraulic placard - CORRECT ANSWER-sign attached to a hydraulically
calculated sprinkler system indicating the design density, required gallons per
minute and pressure for the system to operate properly

hydraulically calculated systems - CORRECT ANSWER-method of sizing auto
sprinkler piping using a prescribed amount of water to be distributed over a
specific area.

impairment coordinator - CORRECT ANSWER-in charge of safety during out of
service systems

intermediate level sprinkler - CORRECT ANSWER-sprinkler equipped with
integral shields to protect the operating elemtn form discharge from sprinklers
installed at higher elevations

large orifice sprinkler - CORRECT ANSWER-sprinkler head with orifice size
equal or greater than 3/4 and less than 1 inch

listed device - CORRECT ANSWER-A fire protection component that has been
tested to perform under parameters specified for its use by a nationally
recognized testing agency. Underwriter's Laboratory (UL) and Factory Mutual
(FM) are the two most common.

Master Pressure Reducing Valve - CORRECT ANSWER-A pressure reducing
valve installed to regulate pressures in an entire fire protection system and/or
standpipe system zone.

Main Drain - CORRECT ANSWER-The primary drain connection located on the
system riser and also utilized as a flow test connection.

Microbiologically Influenced Corrosion (MIC) - CORRECT ANSWER-Corrosion
caused by the presence of microbes in the water supply that over time attack the
interior of metallic piping and cause leaks, pitting, and blockages.

Old-Style/Conventional Sprinkler - CORRECT ANSWER-A sprinkler that directs
40% to 60% of the water initially in a downward direction and is designed to be
installed with the deflector in either the upright or pendent position.

, Pendent Sprinkler - CORRECT ANSWER-A sprinkler designed to be installed in
such a way that the water stream is directed downward against the deflector.

Pintle Screws - CORRECT ANSWER-A visual indicating device required for
sprinklers manufactured prior to 1999 identifying small orifice sprinklers and large
orifice sprinklers where orifice size is different than the nominal thread size of the
sprinkler head.

Pipe Schedule Systems - CORRECT ANSWER-A method of sizing piping based
upon the number of sprinkler heads and the occupancy of the protected area.

Preaction Sprinkler System - CORRECT ANSWER-A sprinkler system employing
automatic sprinklers that are attached to a piping system that contains air that
may or may not be under pressure, with a supplemental detection system
installed in the same areas as the sprinklers.

Pressure Control Valve - CORRECT ANSWER-A pilot operated pressure
reducing valve that may be used with a fire or booster pump designed for the
purpose of preventing the incoming water supply pressure from dropping below a
set pressure.

Pressure-Reducing Valve - CORRECT ANSWER-A valve designed for the
purpose of reducing the downstream water pressure under both flowing
(residual) and nonflowing (static) conditions.

Pressure Relief Valve - CORRECT ANSWER-A valve designed for the purpose
of releasing excess air or water pressure from the Fire Protection Piping System.

Pressure Tank - CORRECT ANSWER-A tank using air pressure to supplying
water for water-based fire protection systems. Tank contents to be maintained at
one third air to two thirds water.

Quick Response Sprinkler Head - CORRECT ANSWER-A sprinkler having a
fusible link with a response time index (RTI) of 50 or less.

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller TUTORSON. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for CA$18.68. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

80202 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
CA$18.68
  • (0)
  Add to cart