[Show more]1.	Recovery equipemnt used for the service or repair of small appliances must be certified by an EPA approved lab if the recovery equipment was made after 
Answer November 15, 1993 
 
2.	Recovery devices made before 11-15-93 and are used for recovery of re- frigerant from small appliances must be ca...
Preview 2 out of 8 pages
Add to cart1.	Recovery equipemnt used for the service or repair of small appliances must be certified by an EPA approved lab if the recovery equipment was made after 
Answer November 15, 1993 
 
2.	Recovery devices made before 11-15-93 and are used for recovery of re- frigerant from small appliances must be ca...
1.	If a leaking appliance with a regulated refrigerant is not going to be repaired, it must be; 
A retrofitted or retired within 3 months. B retrofitted or retired within 12 months. C replaced within 3 months. 
D replaced within 12 months.: B retrofitted or retired within 12 months. 
2.	A high-press...
Preview 2 out of 10 pages
Add to cart1.	If a leaking appliance with a regulated refrigerant is not going to be repaired, it must be; 
A retrofitted or retired within 3 months. B retrofitted or retired within 12 months. C replaced within 3 months. 
D replaced within 12 months.: B retrofitted or retired within 12 months. 
2.	A high-press...
1.	On low pressure chillers, moisture typically enters the refrigerant system through 
Answer air leaks from areas with gaskets or fittings 
 
2.	The maximum test pressure for leak testing a low pressure centrifugal is 
Answer 10 psig 
 
 
3.	Leak test and repair the chiller to reduce refrigerant lo...
Preview 3 out of 24 pages
Add to cart1.	On low pressure chillers, moisture typically enters the refrigerant system through 
Answer air leaks from areas with gaskets or fittings 
 
2.	The maximum test pressure for leak testing a low pressure centrifugal is 
Answer 10 psig 
 
 
3.	Leak test and repair the chiller to reduce refrigerant lo...
1x sold
1.	Before charging a new system with refrigerant, what should be done 
Answer:?: Pres- surize with nitrogen (classified as an inert gas) and leak 
 
2.	Which refrigerant can be used for leak detection as a trace gas and pres- surized 
with nitrogen 
 Answer:?: R-22 
 
3.	What tools can you use to fi...
Preview 3 out of 18 pages
Add to cart1.	Before charging a new system with refrigerant, what should be done 
Answer:?: Pres- surize with nitrogen (classified as an inert gas) and leak 
 
2.	Which refrigerant can be used for leak detection as a trace gas and pres- surized 
with nitrogen 
 Answer:?: R-22 
 
3.	What tools can you use to fi...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller BESTGOODIES. Stuvia facilitates payment to the seller.
No, you only buy these notes for $70.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
67096 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now