Package deal
EPA 608 Certification ALL BUNDLED HERE!!! 2024( A GRADED 100% VERIFIED BY EXPERTS ) FULL PACKED SOLUTION
EPA 608 Certification ALL BUNDLED HERE!!! 2024( A GRADED 100% VERIFIED BY EXPERTS ) FULL PACKED SOLUTION
[Show more]EPA 608 Certification ALL BUNDLED HERE!!! 2024( A GRADED 100% VERIFIED BY EXPERTS ) FULL PACKED SOLUTION
[Show more]What date was the sale of CFC's & HCFC's restricted to technicians certified in refrigerant recovery? - ANSWER November 14, 1994 
 
Section 608 of the Federal Clean Air Act requires technicians to what? - ANSWER Recover all refrigerants. 
 
The objective of the Clean Air Act is to protect ...
Preview 2 out of 6 pages
Add to cartWhat date was the sale of CFC's & HCFC's restricted to technicians certified in refrigerant recovery? - ANSWER November 14, 1994 
 
Section 608 of the Federal Clean Air Act requires technicians to what? - ANSWER Recover all refrigerants. 
 
The objective of the Clean Air Act is to protect ...
Are there drop-in replacements for R-12 systems? Why or why not? - ANSWER No because the new refrigerants are incompatible with the oils and lubricants used in R-12 systems. 
 
What type of oil is used in R-134a and what oils will it mix with? - ANSWER Ester based oils and they do not mix with...
Preview 2 out of 9 pages
Add to cartAre there drop-in replacements for R-12 systems? Why or why not? - ANSWER No because the new refrigerants are incompatible with the oils and lubricants used in R-12 systems. 
 
What type of oil is used in R-134a and what oils will it mix with? - ANSWER Ester based oils and they do not mix with...
a vacum pump should be connected - ANSWER as far away from the pump as possible 
 
a high capacity vacuum pump and short, large diameter hoses will - ANSWER dramatically reduce emissions, pressure drop, and evacuation/dehydration time 
 
ozone contains three - ANSWER oxygen atoms 
 
one ...
Preview 2 out of 6 pages
Add to carta vacum pump should be connected - ANSWER as far away from the pump as possible 
 
a high capacity vacuum pump and short, large diameter hoses will - ANSWER dramatically reduce emissions, pressure drop, and evacuation/dehydration time 
 
ozone contains three - ANSWER oxygen atoms 
 
one ...
As of what date did it become unlawful to release Class 1 and Class II 
refrigerants to the atmosphere? 
a. July 1, 1992 
b. July 1, 1993 
c. November 14, 1994 
d. January 1, 1996 - ANSWER a. July 1, 1992 
 
What is the ozone layer and why is it important to us on Earth? 
a. Thin layer of R-22 in...
Preview 4 out of 53 pages
Add to cartAs of what date did it become unlawful to release Class 1 and Class II 
refrigerants to the atmosphere? 
a. July 1, 1992 
b. July 1, 1993 
c. November 14, 1994 
d. January 1, 1996 - ANSWER a. July 1, 1992 
 
What is the ozone layer and why is it important to us on Earth? 
a. Thin layer of R-22 in...
Which Refrigerants contain the most chlorine? - ANSWER CFC's 
 
As of what date did it become unlawful to intentionally release Class 1 and Class 2 refrigerants to the atmosphere? - ANSWER July 1, 1992 
 
Which Refrigerants have the lowest zone depletion potential? - ANSWER HFC's 
 
The m...
Preview 2 out of 8 pages
Add to cartWhich Refrigerants contain the most chlorine? - ANSWER CFC's 
 
As of what date did it become unlawful to intentionally release Class 1 and Class 2 refrigerants to the atmosphere? - ANSWER July 1, 1992 
 
Which Refrigerants have the lowest zone depletion potential? - ANSWER HFC's 
 
The m...
Refrigeration technicians who violate the Clean Air Act can: - - ANSWER Lose their EPA certification, be fined, be required to appear in Federal court. 
 
After 1995, any supplies of CFC refrigerants to service existing units in the USA can only come from: - - ANSWER recovery and recycling. ...
Preview 2 out of 12 pages
Add to cartRefrigeration technicians who violate the Clean Air Act can: - - ANSWER Lose their EPA certification, be fined, be required to appear in Federal court. 
 
After 1995, any supplies of CFC refrigerants to service existing units in the USA can only come from: - - ANSWER recovery and recycling. ...
When moisture exists in an operating system, what is most likely to occur? - ANSWER Acid will form. 
 
What factor(s) affects the speed of evacuation? - ANSWER 1) The size of the equipment being evacuated. 
 
2)The ambient temperature. 
 
3) The amount of moisture in the system 
 
A system i...
Preview 1 out of 2 pages
Add to cartWhen moisture exists in an operating system, what is most likely to occur? - ANSWER Acid will form. 
 
What factor(s) affects the speed of evacuation? - ANSWER 1) The size of the equipment being evacuated. 
 
2)The ambient temperature. 
 
3) The amount of moisture in the system 
 
A system i...
What are the typical uses of the center port of gauge set? - ANSWER Used during evacuation, charging and recovery procedures. 
 
What color are the gauges on a manifold gauge set? - ANSWER Low pressure is blue, High pressure is red. 
 
What are the typical ranges of pressure measurements used ...
Preview 3 out of 22 pages
Add to cartWhat are the typical uses of the center port of gauge set? - ANSWER Used during evacuation, charging and recovery procedures. 
 
What color are the gauges on a manifold gauge set? - ANSWER Low pressure is blue, High pressure is red. 
 
What are the typical ranges of pressure measurements used ...
November 14, 1994 - ANSWER What date was the sale of CFC's & HCFC's restricted to technicians certified in refrigerant recovery? 
 
Memorize it, ya'll. - ANSWER 1987- 
Montreal Protocol 
 
July 1 1992- 
Violation to vent CFCs or HCFCs 
 
Nov 15 1993- 
Recovery/Recycling equipment must...
Preview 3 out of 22 pages
Add to cartNovember 14, 1994 - ANSWER What date was the sale of CFC's & HCFC's restricted to technicians certified in refrigerant recovery? 
 
Memorize it, ya'll. - ANSWER 1987- 
Montreal Protocol 
 
July 1 1992- 
Violation to vent CFCs or HCFCs 
 
Nov 15 1993- 
Recovery/Recycling equipment must...
The sale of reclaimed CFC, HCFC, HFC, and HFO refrigerants is_______. - ANSWER Restricted to technicians who are EPA certified and refrigerant recovery 
 
A small Pliance is defined as a system that is - ANSWER Manufactured, fully charged, and hermetically sealed in a factory with a charge of ...
Preview 1 out of 4 pages
Add to cartThe sale of reclaimed CFC, HCFC, HFC, and HFO refrigerants is_______. - ANSWER Restricted to technicians who are EPA certified and refrigerant recovery 
 
A small Pliance is defined as a system that is - ANSWER Manufactured, fully charged, and hermetically sealed in a factory with a charge of ...
If a leaking appliance with a regulated refrigerant is not going to be repaired, it must be; 
A retrofitted or retired within 3 months. 
B retrofitted or retired within 12 months. 
C replaced within 3 months. 
D replaced within 12 months. - ANSWER B 
retrofitted or retired within 12 months. 
 
A h...
Preview 2 out of 5 pages
Add to cartIf a leaking appliance with a regulated refrigerant is not going to be repaired, it must be; 
A retrofitted or retired within 3 months. 
B retrofitted or retired within 12 months. 
C replaced within 3 months. 
D replaced within 12 months. - ANSWER B 
retrofitted or retired within 12 months. 
 
A h...
Reusable refrigerant containers under high-pressure must be hydrostatically tested how often? - ANSWER 5 years 
 
How much can a person be fined per day per violation for knowingly releasing a regulated substance that violates the Clean Air Act? - ANSWER $44,539 
 
HCFCs contain - ANSWER Hy...
Preview 2 out of 8 pages
Add to cartReusable refrigerant containers under high-pressure must be hydrostatically tested how often? - ANSWER 5 years 
 
How much can a person be fined per day per violation for knowingly releasing a regulated substance that violates the Clean Air Act? - ANSWER $44,539 
 
HCFCs contain - ANSWER Hy...
To process refrigerant to a level that is equal to new product specifications as - ANSWER Reclaiming 
 
The low side test pressure data plate value should be used by a technician to determine a safe pressure for - ANSWER Leak testing 
 
Silicone elastomers are not compatible with what refriger...
Preview 2 out of 5 pages
Add to cartTo process refrigerant to a level that is equal to new product specifications as - ANSWER Reclaiming 
 
The low side test pressure data plate value should be used by a technician to determine a safe pressure for - ANSWER Leak testing 
 
Silicone elastomers are not compatible with what refriger...
To process refrigerant to a level that is equal to new product specifications as - ANSWER Reclaiming 
 
The low side test pressure data plate value should be used by a technician to determine a safe pressure for - ANSWER Leak testing 
 
Silicone elastomers are not compatible with what refriger...
Preview 2 out of 5 pages
Add to cartTo process refrigerant to a level that is equal to new product specifications as - ANSWER Reclaiming 
 
The low side test pressure data plate value should be used by a technician to determine a safe pressure for - ANSWER Leak testing 
 
Silicone elastomers are not compatible with what refriger...
Industrial process and refrigeration units with a 50 pound charge or more with an annualized leak rate of _____ or more must have leaks repaired. - ANSWER 35 
 
Unless plans are made to replace a system exceeding the maximum leak, repairs must be made in; - ANSWER 30 days 
 
Refrigerants CFC...
Preview 1 out of 2 pages
Add to cartIndustrial process and refrigeration units with a 50 pound charge or more with an annualized leak rate of _____ or more must have leaks repaired. - ANSWER 35 
 
Unless plans are made to replace a system exceeding the maximum leak, repairs must be made in; - ANSWER 30 days 
 
Refrigerants CFC...
Before charging a new system with refrigerant, what should be done? - ANSWER Pressurize with nitrogen (classified as an inert gas) and leak 
 
Which refrigerant can be used for leak detection as a trace gas and pressurized 
with nitrogen? - ANSWER R-22 
 
What tools can you use to find gener...
Preview 2 out of 9 pages
Add to cartBefore charging a new system with refrigerant, what should be done? - ANSWER Pressurize with nitrogen (classified as an inert gas) and leak 
 
Which refrigerant can be used for leak detection as a trace gas and pressurized 
with nitrogen? - ANSWER R-22 
 
What tools can you use to find gener...
When a new system has been assembled, the first thing to do is? - ANSWER Pressurize the system with an inert gas & leak check. 
 
After installation of a field-piped R-410A split heat pulp, the unit should first be? - ANSWER Pressurized with nitrogen then leak checked. 
 
The EPA regulations...
Preview 2 out of 6 pages
Add to cartWhen a new system has been assembled, the first thing to do is? - ANSWER Pressurize the system with an inert gas & leak check. 
 
After installation of a field-piped R-410A split heat pulp, the unit should first be? - ANSWER Pressurized with nitrogen then leak checked. 
 
The EPA regulations...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller STARSHINESTUVIA. Stuvia facilitates payment to the seller.
No, you only buy these notes for $88.98. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
62890 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now