[Show more]A patient with a chest tube arrives in the nuclear medicine department for an Imaging study. The technologist should: 
 
A. Cancel the procedure because the chest tube apparatus will interfere with the study 
 
B. Place the chest tubes external apparatus on the Imaging table next to the patient 
 
C...
Preview 4 out of 32 pages
Add to cartA patient with a chest tube arrives in the nuclear medicine department for an Imaging study. The technologist should: 
 
A. Cancel the procedure because the chest tube apparatus will interfere with the study 
 
B. Place the chest tubes external apparatus on the Imaging table next to the patient 
 
C...
1. Before tracer administration, all the following preparations are required for a 27 year old woman referred for total-body bone imaging except: 
 
A.) removing attenuation materials from the patient 
B.) answering the patients questions 
C.) ruling out pregnancy 
D.) explaining the procedure to th...
Preview 3 out of 26 pages
Add to cart1. Before tracer administration, all the following preparations are required for a 27 year old woman referred for total-body bone imaging except: 
 
A.) removing attenuation materials from the patient 
B.) answering the patients questions 
C.) ruling out pregnancy 
D.) explaining the procedure to th...
Mixed AttentuationMalignant Pulmonary Nodules on CT are characterized by: 
 
Reed-Sternberg CellsHodkin's Lymphoma is separated from other Lymphomas by the presence of: 
 
Acetylecholinestrearse Inhibitors 
N-methyl-D-aspartate receptor antagonistsTwo types of Alzheimer's mediciation: 
 
Left Subc...
Preview 4 out of 43 pages
Add to cartMixed AttentuationMalignant Pulmonary Nodules on CT are characterized by: 
 
Reed-Sternberg CellsHodkin's Lymphoma is separated from other Lymphomas by the presence of: 
 
Acetylecholinestrearse Inhibitors 
N-methyl-D-aspartate receptor antagonistsTwo types of Alzheimer's mediciation: 
 
Left Subc...
According to NRC criteria, which of the following is a misadministration? 
 
a. Infiltration of an attempted intravenous injection 
b. Administration of 10 mCi I-131 instead of the prescribed 9 mCi 
c. Administration of 20 mCi Tc-99m pertechnetate instead of the prescribed 10 mCi 
d. Administration ...
Preview 2 out of 12 pages
Add to cartAccording to NRC criteria, which of the following is a misadministration? 
 
a. Infiltration of an attempted intravenous injection 
b. Administration of 10 mCi I-131 instead of the prescribed 9 mCi 
c. Administration of 20 mCi Tc-99m pertechnetate instead of the prescribed 10 mCi 
d. Administration ...
Nuclides with the same atomic number ( the same number of protons) but a different number of neutrons are called: isotopes 
 
Two nuclides with the same atomic mass but different atomic numbers are called: isobars 
 
A nuclide that emits particulate or photon energy to achieve a more stable state: r...
Preview 4 out of 35 pages
Add to cartNuclides with the same atomic number ( the same number of protons) but a different number of neutrons are called: isotopes 
 
Two nuclides with the same atomic mass but different atomic numbers are called: isobars 
 
A nuclide that emits particulate or photon energy to achieve a more stable state: r...
What is being evaluated with chromatography testing of technetium radiopharmaceuticals 
A. Aluminum Contamination 
B. Molybdenum Breakthrough 
C. Radionuclidic Purity 
D. Radiochemical Purity 
E. Chemical Purity D. Radiochemical Purity 
 
The use of elliptical and or body counter orbits in SPECT i...
Preview 2 out of 5 pages
Add to cartWhat is being evaluated with chromatography testing of technetium radiopharmaceuticals 
A. Aluminum Contamination 
B. Molybdenum Breakthrough 
C. Radionuclidic Purity 
D. Radiochemical Purity 
E. Chemical Purity D. Radiochemical Purity 
 
The use of elliptical and or body counter orbits in SPECT i...
18F-FDG is rarely used to image tumors in the kidney, prostate, or bladder because: FDG is actively excreted in the urine, obscuring tumor uptake in these organs 
 
A patient who is maintained on a ventilator is transported to the nuclear medicine department. In the transfer process, it is necessary...
Preview 1 out of 4 pages
Add to cart18F-FDG is rarely used to image tumors in the kidney, prostate, or bladder because: FDG is actively excreted in the urine, obscuring tumor uptake in these organs 
 
A patient who is maintained on a ventilator is transported to the nuclear medicine department. In the transfer process, it is necessary...
what are survey meters used to measure? radiation exposure rates 
 
what type of survey meter is used for surveys to detect contamination? Geiger-Muller (GM) counter 
 
The NRC requires that a nuc med facility have a survey meter capable of detecting exposure rates between what range? and what instr...
Preview 2 out of 9 pages
Add to cartwhat are survey meters used to measure? radiation exposure rates 
 
what type of survey meter is used for surveys to detect contamination? Geiger-Muller (GM) counter 
 
The NRC requires that a nuc med facility have a survey meter capable of detecting exposure rates between what range? and what instr...
In which RP is Tc99m left in the valence state of +7 
a. sulfur colloid 
b. MAA 
c. MAG3 
d. sestamibi A. Sulfur colloid 
 
a tech receives a request for a patient to receive Sm153 for palliation of pain from bone mets. the patient has a WBC count of 3500 and 40000 platelets. what should happen next...
Preview 2 out of 15 pages
Add to cartIn which RP is Tc99m left in the valence state of +7 
a. sulfur colloid 
b. MAA 
c. MAG3 
d. sestamibi A. Sulfur colloid 
 
a tech receives a request for a patient to receive Sm153 for palliation of pain from bone mets. the patient has a WBC count of 3500 and 40000 platelets. what should happen next...
Gas Ventilation Xe 133, 81 KeV, 5.3 half life; reactor produced 
dose: 10-20 mCi 
imaging: posterior position 
negative pressure room required 
uses activated charcoal trap to accumulate the exhaled xenon gas until decayed to background 
single breath: during inhalation 
wash in / equilibrium : coll...
Preview 3 out of 16 pages
Add to cartGas Ventilation Xe 133, 81 KeV, 5.3 half life; reactor produced 
dose: 10-20 mCi 
imaging: posterior position 
negative pressure room required 
uses activated charcoal trap to accumulate the exhaled xenon gas until decayed to background 
single breath: during inhalation 
wash in / equilibrium : coll...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller twishfrancis. Stuvia facilitates payment to the seller.
No, you only buy these notes for $30.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
67866 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now