Package deal
Oil Burner Exam Bundle Questions and Answers(SCORED A )
Oil Burner Exam Bundle Questions and Answers(SCORED A )
[Show more]Oil Burner Exam Bundle Questions and Answers(SCORED A )
[Show more]Atomizing type burners were designed to burn which type of fuel? - ANSWER-No. 2 fuel oil 
 
Pour point problems with outside above ground fuel tanks can be partially relieved by: - ANSWER-All of the above - relocating the outside fuel filter and strainers to the inside , switching to No. 1 fuel oil,...
Preview 2 out of 8 pages
Add to cartAtomizing type burners were designed to burn which type of fuel? - ANSWER-No. 2 fuel oil 
 
Pour point problems with outside above ground fuel tanks can be partially relieved by: - ANSWER-All of the above - relocating the outside fuel filter and strainers to the inside , switching to No. 1 fuel oil,...
SSU - ANSWER-Say bolt both seconds universal 
 
Carbon residue - ANSWER-Amount of carbon left in a sample of oil after boiling oxygen-free atmosphere 
 
Pour point - ANSWER-Lowest temperature at which the fuel can be stored and handled 
 
Ash content - ANSWER-Amount of non combustible materials cont...
Preview 1 out of 4 pages
Add to cartSSU - ANSWER-Say bolt both seconds universal 
 
Carbon residue - ANSWER-Amount of carbon left in a sample of oil after boiling oxygen-free atmosphere 
 
Pour point - ANSWER-Lowest temperature at which the fuel can be stored and handled 
 
Ash content - ANSWER-Amount of non combustible materials cont...
Oil Burner Motor - ANSWER-Drives the blower wheel and fuel pump by means of a shaft coupling, spins at 3600rpms 
 
Squirrel Cage - ANSWER-Cylinder shaped fan assembly used to move air 
 
Coupling - ANSWER-A device for joining 2 fluid-flow lines 
 
Oil Pump - ANSWER-Transfers oil from the supply tank...
Preview 1 out of 2 pages
Add to cartOil Burner Motor - ANSWER-Drives the blower wheel and fuel pump by means of a shaft coupling, spins at 3600rpms 
 
Squirrel Cage - ANSWER-Cylinder shaped fan assembly used to move air 
 
Coupling - ANSWER-A device for joining 2 fluid-flow lines 
 
Oil Pump - ANSWER-Transfers oil from the supply tank...
The reducing of oil into very small particles is termed 
 
a) fluidization 
 
b) fractionation 
 
c) turbulence 
 
d) atomization 
 
e) distillation - ANSWER-d 
 
Before atomization can occur, heavy oils are heated to 
approximately 
 
a) 203 degrees C 
 
b) 95 degrees C 
 
c) 115 degrees C 
 
d) 75...
Preview 2 out of 9 pages
Add to cartThe reducing of oil into very small particles is termed 
 
a) fluidization 
 
b) fractionation 
 
c) turbulence 
 
d) atomization 
 
e) distillation - ANSWER-d 
 
Before atomization can occur, heavy oils are heated to 
approximately 
 
a) 203 degrees C 
 
b) 95 degrees C 
 
c) 115 degrees C 
 
d) 75...
Cast iron fittings can be used in heating fuel systems? - ANSWER-False 
 
Tank vent shall terminate - ANSWER-Within 12 feet of the fill and visible from the fill 
 
Tanks exceeding 330 gallons must have - ANSWER-Top supply connection 
 
Fuel return piping from an appliance shall - ANSWER-Enter the t...
Preview 3 out of 19 pages
Add to cartCast iron fittings can be used in heating fuel systems? - ANSWER-False 
 
Tank vent shall terminate - ANSWER-Within 12 feet of the fill and visible from the fill 
 
Tanks exceeding 330 gallons must have - ANSWER-Top supply connection 
 
Fuel return piping from an appliance shall - ANSWER-Enter the t...
boiler heats up hot water w/ a series of piping and circulates it - ANSWER-How does a hot water heating system operate? 
 
Uses a burner to heat the heat exchanger and uses a blower to blow across heat exchanger to travel to air duct work - ANSWER-How does a warm air heating system operate? 
 
1. pr...
Preview 1 out of 4 pages
Add to cartboiler heats up hot water w/ a series of piping and circulates it - ANSWER-How does a hot water heating system operate? 
 
Uses a burner to heat the heat exchanger and uses a blower to blow across heat exchanger to travel to air duct work - ANSWER-How does a warm air heating system operate? 
 
1. pr...
The heat anticipator in a thermostat is adjusted by the millivolts of the secondary circuit: T or F - ANSWER-True 
 
In MA 527CMR4.00 all electrical safety switches are wired in series: T or F - ANSWER-True 
 
A power venter is an electrically operated mechanical fan to exhaust combustion gas: T or ...
Preview 1 out of 4 pages
Add to cartThe heat anticipator in a thermostat is adjusted by the millivolts of the secondary circuit: T or F - ANSWER-True 
 
In MA 527CMR4.00 all electrical safety switches are wired in series: T or F - ANSWER-True 
 
A power venter is an electrically operated mechanical fan to exhaust combustion gas: T or ...
Combustion air for an oil burner is provided​ by_____. - ANSWER-a combustion air fan 
 
The output of the ignition transformer​ is_____. - ANSWER-10,000 volts 
 
The primary control starts burner operation in response to a signal from​ the_____. - ANSWER-room thermostat 
 
When replacing an oi...
Preview 1 out of 1 pages
Add to cartCombustion air for an oil burner is provided​ by_____. - ANSWER-a combustion air fan 
 
The output of the ignition transformer​ is_____. - ANSWER-10,000 volts 
 
The primary control starts burner operation in response to a signal from​ the_____. - ANSWER-room thermostat 
 
When replacing an oi...
Igniter - ANSWER-sends high-voltage electricity to electrodes 
 
System Thermostat - ANSWER-calls for heat to initiate the cycle 
 
Burner motor - ANSWER-provides combustion air for the furnace and turns the pump in the fuel oil 
 
Primary control unit - ANSWER-Operates majority of the devices in a ...
Preview 2 out of 5 pages
Add to cartIgniter - ANSWER-sends high-voltage electricity to electrodes 
 
System Thermostat - ANSWER-calls for heat to initiate the cycle 
 
Burner motor - ANSWER-provides combustion air for the furnace and turns the pump in the fuel oil 
 
Primary control unit - ANSWER-Operates majority of the devices in a ...
#2 fuel oil - ANSWER-most frequently used and burns at 140,000 BTU per gallon 
 
air bend - ANSWER-regulates the volume (amount) by changing it to a spray of tiny droplets 
 
atomizing - ANSWER-vaporizing liquid oil (turning it into gas) by changing it to a spray of tiny droplets 
 
bleeder - ANSWER...
Preview 1 out of 2 pages
Add to cart#2 fuel oil - ANSWER-most frequently used and burns at 140,000 BTU per gallon 
 
air bend - ANSWER-regulates the volume (amount) by changing it to a spray of tiny droplets 
 
atomizing - ANSWER-vaporizing liquid oil (turning it into gas) by changing it to a spray of tiny droplets 
 
bleeder - ANSWER...
You come across an oil furnace that has a tripped primary control. You should 
 
A) 
reset the primary controller and attempt to fire the burner. 
 B) 
not reset the primary control, and attempt to view the firepot for pooling oil. 
 C) 
reset the primary control, but do not attempt to fire the burn...
Preview 2 out of 7 pages
Add to cartYou come across an oil furnace that has a tripped primary control. You should 
 
A) 
reset the primary controller and attempt to fire the burner. 
 B) 
not reset the primary control, and attempt to view the firepot for pooling oil. 
 C) 
reset the primary control, but do not attempt to fire the burn...
whats a good defintion for viscosity - ANSWER-viscosity is resistance to flow 
 
whats the flash point of number 2 heating fuel - ANSWER-115 degrees 
 
whats the pour point of number 2 heating fuel - ANSWER-17 degress farenheit 
 
what is a btu - ANSWER-the amount of energy to raise one pound of wat...
Preview 2 out of 7 pages
Add to cartwhats a good defintion for viscosity - ANSWER-viscosity is resistance to flow 
 
whats the flash point of number 2 heating fuel - ANSWER-115 degrees 
 
whats the pour point of number 2 heating fuel - ANSWER-17 degress farenheit 
 
what is a btu - ANSWER-the amount of energy to raise one pound of wat...
What causes oil tanks to rust? - ANSWER-the air int he tank condenses and forms water 
 
Where will the oil filter be located in the oil supply line? - ANSWER-Between the tank and the oil burner 
 
NAAHT a function of the primary control on an oil burner - ANSWER-to sense air temperatures in furnace...
Preview 1 out of 1 pages
Add to cartWhat causes oil tanks to rust? - ANSWER-the air int he tank condenses and forms water 
 
Where will the oil filter be located in the oil supply line? - ANSWER-Between the tank and the oil burner 
 
NAAHT a function of the primary control on an oil burner - ANSWER-to sense air temperatures in furnace...
Ch 1 High Pressure Atomizing - ANSWER-100+ PSI fuel pump forces oil through a nozel to break (atomize) the oil into small droplets thst are vaporized abd burned in suspension in the combustion area. Electrodes close to the nozzle supplies heat for ignition and a fan supplies the air needed for combu...
Preview 1 out of 2 pages
Add to cartCh 1 High Pressure Atomizing - ANSWER-100+ PSI fuel pump forces oil through a nozel to break (atomize) the oil into small droplets thst are vaporized abd burned in suspension in the combustion area. Electrodes close to the nozzle supplies heat for ignition and a fan supplies the air needed for combu...
The grade of fuel used in residential and light commercial units is ____. - ANSWER-number 2 
 
When the oil tank is above the oil burner pump, the fuel oil supply system would normally be a _____. - ANSWER-gravity flow, one pipe system 
 
An auxiliary tank and booster pump system is 
required if th...
Preview 1 out of 4 pages
Add to cartThe grade of fuel used in residential and light commercial units is ____. - ANSWER-number 2 
 
When the oil tank is above the oil burner pump, the fuel oil supply system would normally be a _____. - ANSWER-gravity flow, one pipe system 
 
An auxiliary tank and booster pump system is 
required if th...
the vertical distance between the center nozzle and electrode tips - ANSWER-above gap 
 
a metal band on an oil burner that is used to regulate the amount of air the burner fan can draw in and blow through the air tube - ANSWER-adjustable air band 
 
the passage through which air from an oil burner ...
Preview 2 out of 8 pages
Add to cartthe vertical distance between the center nozzle and electrode tips - ANSWER-above gap 
 
a metal band on an oil burner that is used to regulate the amount of air the burner fan can draw in and blow through the air tube - ANSWER-adjustable air band 
 
the passage through which air from an oil burner ...
In an electric circuit for the wattage to remain the same if the voltage drops, the amperage must - ANSWER-Increase 
 
Atomizing type burners were designed to burn which type of fuel - ANSWER-Type 2 fuel oil 
 
Pour point problems with outside above ground fuel tanks can be partially relieved by - A...
Preview 3 out of 20 pages
Add to cartIn an electric circuit for the wattage to remain the same if the voltage drops, the amperage must - ANSWER-Increase 
 
Atomizing type burners were designed to burn which type of fuel - ANSWER-Type 2 fuel oil 
 
Pour point problems with outside above ground fuel tanks can be partially relieved by - A...
What is the first thing a tech should do when arriving at a no combustion call? - ANSWER-Ask how many times the customer reset the unit. 
 
What is the best long term solution for preventing a clogged nozzle? - ANSWER--Remove any underground storage tanks. 
-Install a quality oil filter. 
-Cut the...
Preview 3 out of 26 pages
Add to cartWhat is the first thing a tech should do when arriving at a no combustion call? - ANSWER-Ask how many times the customer reset the unit. 
 
What is the best long term solution for preventing a clogged nozzle? - ANSWER--Remove any underground storage tanks. 
-Install a quality oil filter. 
-Cut the...
The main function of the primary control is: - ANSWER-Locking out on safety in the event of flame failure 
 
Power must be provided to an electric blower control board on terminals: - ANSWER-L1 and L2 
 
Once a PSC motor starts - ANSWER-The centrifugal switch turns off the electricity to the capacit...
Preview 2 out of 7 pages
Add to cartThe main function of the primary control is: - ANSWER-Locking out on safety in the event of flame failure 
 
Power must be provided to an electric blower control board on terminals: - ANSWER-L1 and L2 
 
Once a PSC motor starts - ANSWER-The centrifugal switch turns off the electricity to the capacit...
Max safety timing on a primary control - ANSWER-15 seconds 
 
Safety control circuits shall be - ANSWER-2-wire, one side grounded, with nominal voltage not exceeding 150v 
 
Crankcase/used oil may only be used in - ANSWER-Commercial/industrial setting. Or in a appliance specifically designed to do s...
Preview 2 out of 6 pages
Add to cartMax safety timing on a primary control - ANSWER-15 seconds 
 
Safety control circuits shall be - ANSWER-2-wire, one side grounded, with nominal voltage not exceeding 150v 
 
Crankcase/used oil may only be used in - ANSWER-Commercial/industrial setting. Or in a appliance specifically designed to do s...
What are the 3 funtions of an Oil Burner nozzle? - ANSWER-Atomize, Meter, Patter. 
 
What are the 2 voltage circuits of a primary control? - ANSWER-Line & Low. 
 
What is the function of a fuse? - ANSWER-Protect circuit. 
 
What is the High Limit cut out? - ANSWER-Max safe Temp or Pressure setting. ...
Preview 2 out of 9 pages
Add to cartWhat are the 3 funtions of an Oil Burner nozzle? - ANSWER-Atomize, Meter, Patter. 
 
What are the 2 voltage circuits of a primary control? - ANSWER-Line & Low. 
 
What is the function of a fuse? - ANSWER-Protect circuit. 
 
What is the High Limit cut out? - ANSWER-Max safe Temp or Pressure setting. ...
A fuel oil storage tank cannot be installed: - ANSWER-In the furnace room 5 feet within heating unit 
 
What temperature does a thermal wheel automatically activate at - ANSWER-165°F 
 
Who inspects an oil burner installation - ANSWER-State fire marshal 
 
Any valve used on a oil burner install mus...
Preview 2 out of 8 pages
Add to cartA fuel oil storage tank cannot be installed: - ANSWER-In the furnace room 5 feet within heating unit 
 
What temperature does a thermal wheel automatically activate at - ANSWER-165°F 
 
Who inspects an oil burner installation - ANSWER-State fire marshal 
 
Any valve used on a oil burner install mus...
oil burner motor - ANSWER-spins at 1725 rpm and rotates the fuel pump and coupling 
 
coupling - ANSWER-the connection between the fuel pump and oil burner motor 
 
housing - ANSWER-encases the burner and all of its components in the heating unit 
 
fuel line - ANSWER-a line meant for the passing of...
Preview 1 out of 1 pages
Add to cartoil burner motor - ANSWER-spins at 1725 rpm and rotates the fuel pump and coupling 
 
coupling - ANSWER-the connection between the fuel pump and oil burner motor 
 
housing - ANSWER-encases the burner and all of its components in the heating unit 
 
fuel line - ANSWER-a line meant for the passing of...
The cross connection between two supply tanks shall not exceed? - ANSWER-660 gallons 
 
When is an automatic draft control not required? - ANSWER-When the equipment is designed to control the draft. 
 
Combustion performance testing can indicate: - ANSWER-Improper air oil mixture, too much combustio...
Preview 2 out of 5 pages
Add to cartThe cross connection between two supply tanks shall not exceed? - ANSWER-660 gallons 
 
When is an automatic draft control not required? - ANSWER-When the equipment is designed to control the draft. 
 
Combustion performance testing can indicate: - ANSWER-Improper air oil mixture, too much combustio...
What are 2 ways the fuel flow rate is set on an oil burner? - ANSWER-Nozzle, size and oil pressure. 
 
List three things needed for ignition? - ANSWER-Fuel, air and spark. 
 
Flame Retention Burners have what advantage over Non Flame Retention? - ANSWER-Better air to oil mixture and cleaner burning....
Preview 2 out of 5 pages
Add to cartWhat are 2 ways the fuel flow rate is set on an oil burner? - ANSWER-Nozzle, size and oil pressure. 
 
List three things needed for ignition? - ANSWER-Fuel, air and spark. 
 
Flame Retention Burners have what advantage over Non Flame Retention? - ANSWER-Better air to oil mixture and cleaner burning....
What is the largest exposed tank allowed in a building without a permit - ANSWER-660 g 
 
What is tank approval - ANSWER-UL 80 UL 142 
 
A supply tank shall be securely supported by ridged, non-combustible supports to prevent settling, sliding or lifting. true or false - ANSWER-True 
 
What is the l...
Preview 2 out of 15 pages
Add to cartWhat is the largest exposed tank allowed in a building without a permit - ANSWER-660 g 
 
What is tank approval - ANSWER-UL 80 UL 142 
 
A supply tank shall be securely supported by ridged, non-combustible supports to prevent settling, sliding or lifting. true or false - ANSWER-True 
 
What is the l...
Number 2 oil has what btu's - ANSWER-140,000 
 
Which fuel oil has the lowest viscosity - ANSWER-#1 
 
Fuel oil is made up of mostly - ANSWER-Hydrogen/carbon 
 
Flash point of #2 fuel oil is - ANSWER-115 degrees 
 
Combustion triangle - ANSWER-oxygen, heat, fuel 
 
vent pipes must be atleast ______...
Preview 1 out of 4 pages
Add to cartNumber 2 oil has what btu's - ANSWER-140,000 
 
Which fuel oil has the lowest viscosity - ANSWER-#1 
 
Fuel oil is made up of mostly - ANSWER-Hydrogen/carbon 
 
Flash point of #2 fuel oil is - ANSWER-115 degrees 
 
Combustion triangle - ANSWER-oxygen, heat, fuel 
 
vent pipes must be atleast ______...
1. Question 1 points 
Fuel Pump fail to prime when Suction inlet vacuum is greater than _______ of vacuum 
 
 20 inches 
 30 inches 
 15 inches 
 25 inches - ANSWER-15 inches 
 
Which of the following is used to ignite the fuel oil in the heating system: 
 
 Step down transformer 
 Step up transform...
Preview 1 out of 4 pages
Add to cart1. Question 1 points 
Fuel Pump fail to prime when Suction inlet vacuum is greater than _______ of vacuum 
 
 20 inches 
 30 inches 
 15 inches 
 25 inches - ANSWER-15 inches 
 
Which of the following is used to ignite the fuel oil in the heating system: 
 
 Step down transformer 
 Step up transform...
Oil Burner - ANSWER-A machine that prepares liquid fuel for combustion, starts the combustion process, and projects the resulting flame into a boiler or furnace in which the heat released can be utilized. 
 
3 systems of an oil burner - ANSWER-Every oil burner must have 
an air delivery system, 
a...
Preview 1 out of 2 pages
Add to cartOil Burner - ANSWER-A machine that prepares liquid fuel for combustion, starts the combustion process, and projects the resulting flame into a boiler or furnace in which the heat released can be utilized. 
 
3 systems of an oil burner - ANSWER-Every oil burner must have 
an air delivery system, 
a...
Air Heater. - ANSWER-. An indirect-fired appliance intended to supply heated air for space heating and other purposes, but not intended for permanent installation. 
 
Air pressure switch . - ANSWER-An electrical switch designed to prove that the proper draft has been established by the power venter ...
Preview 2 out of 12 pages
Add to cartAir Heater. - ANSWER-. An indirect-fired appliance intended to supply heated air for space heating and other purposes, but not intended for permanent installation. 
 
Air pressure switch . - ANSWER-An electrical switch designed to prove that the proper draft has been established by the power venter ...
What is the voltage found at the TT terminals - ANSWER-24 volts 
 
What are the 8 steps of a no heat call - ANSWER-1 talk to customer 2 check tt.3 check to make sure an emergency switch is on 4check to make sure there is oil in the tank 5 check to make sure the main power going to the unit is on six...
Preview 3 out of 18 pages
Add to cartWhat is the voltage found at the TT terminals - ANSWER-24 volts 
 
What are the 8 steps of a no heat call - ANSWER-1 talk to customer 2 check tt.3 check to make sure an emergency switch is on 4check to make sure there is oil in the tank 5 check to make sure the main power going to the unit is on six...
What differentiates a flame retention burner from a standard high pressure burner - ANSWER-The flame retention head produces more air swirl and combustion air recirculation flow 
 
Name the three elements needed for combustion - ANSWER-Oil air spark 
 
Which of the three elements needed for combusti...
Preview 1 out of 3 pages
Add to cartWhat differentiates a flame retention burner from a standard high pressure burner - ANSWER-The flame retention head produces more air swirl and combustion air recirculation flow 
 
Name the three elements needed for combustion - ANSWER-Oil air spark 
 
Which of the three elements needed for combusti...
How can you recognize steam heating systems? - ANSWER-gauge glass tube mounted between two valves at top 
 
The purpose of the gauge glass on steam boiler is what? - ANSWER-tells how much water is in boiler 
 
What is also on a steam heating system that tells how much water is in it? - ANSWER-pressu...
Preview 1 out of 2 pages
Add to cartHow can you recognize steam heating systems? - ANSWER-gauge glass tube mounted between two valves at top 
 
The purpose of the gauge glass on steam boiler is what? - ANSWER-tells how much water is in boiler 
 
What is also on a steam heating system that tells how much water is in it? - ANSWER-pressu...
What is the heating value of number 2 heating oil? - ANSWER-140,000 Btu/gallon 
 
What is the common operating pressure of a high pressure oil boiler? - ANSWER-100 PSIG 
 
What is the secondary voltage of the ignition transformer used on a high pressure oil burner? - ANSWER-10,000 volts 
 
What is t...
Preview 2 out of 9 pages
Add to cartWhat is the heating value of number 2 heating oil? - ANSWER-140,000 Btu/gallon 
 
What is the common operating pressure of a high pressure oil boiler? - ANSWER-100 PSIG 
 
What is the secondary voltage of the ignition transformer used on a high pressure oil burner? - ANSWER-10,000 volts 
 
What is t...
In regard to the characteristics of an oil flame, oil-burner flame-detection systems make use of the: - ANSWER-production of heat or visible light. 
 
On a new oil furnace installation, the oil pump pressure is found to be 50 psi. Which, if any, of the following actions should be taken? - ANSWER-inc...
Preview 1 out of 3 pages
Add to cartIn regard to the characteristics of an oil flame, oil-burner flame-detection systems make use of the: - ANSWER-production of heat or visible light. 
 
On a new oil furnace installation, the oil pump pressure is found to be 50 psi. Which, if any, of the following actions should be taken? - ANSWER-inc...
T/F A converted furnace or boiler is best sized according to the heat loss of the house? - ANSWER-True 
 
The ------- must advise the user of an appliance when converting an oil-fired boiler to natural gas to have the oil fill and vent pipes removed - ANSWER-Installer 
 
T/F The existing combustion ...
Preview 2 out of 8 pages
Add to cartT/F A converted furnace or boiler is best sized according to the heat loss of the house? - ANSWER-True 
 
The ------- must advise the user of an appliance when converting an oil-fired boiler to natural gas to have the oil fill and vent pipes removed - ANSWER-Installer 
 
T/F The existing combustion ...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller IMORA. Stuvia facilitates payment to the seller.
No, you only buy these notes for $30.99. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
82871 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now