Package deal
HVACR Package Deal With Verified Study Solutions (Questions And Answers) Rated A+
HVACR Package Deal With Verified Study Solutions (Questions And Answers) Rated A+
[Show more]HVACR Package Deal With Verified Study Solutions (Questions And Answers) Rated A+
[Show more]he rating scale used to show how efficient a room air-conditioner is operating based on the power 
being consumed is? - Energy Efficiency Ratio 
The rating scale used to measure how efficiently a cooling system will operate over an entire season is? - 
Seasonal Energy Efficiency Ratio 
The efficienc...
Preview 1 out of 3 pages
Add to carthe rating scale used to show how efficient a room air-conditioner is operating based on the power 
being consumed is? - Energy Efficiency Ratio 
The rating scale used to measure how efficiently a cooling system will operate over an entire season is? - 
Seasonal Energy Efficiency Ratio 
The efficienc...
A technician uses an ohmmeter to check resistance and for a complete path in the electrical circuit, also 
known as: - Continuity. 
A wattmeter is connected to a circuit with 120 V, 10 A, and a power factor of 91.7%. Its reading is: - 
1,100 W. 
An ohmmeter is set on continuity and beeps when the le...
Preview 1 out of 4 pages
Add to cartA technician uses an ohmmeter to check resistance and for a complete path in the electrical circuit, also 
known as: - Continuity. 
A wattmeter is connected to a circuit with 120 V, 10 A, and a power factor of 91.7%. Its reading is: - 
1,100 W. 
An ohmmeter is set on continuity and beeps when the le...
A metering device provides a small opening, or orifice, through - which only a certain amount of 
refrigerant flows into the evaporator. 
A metering orifice is installed between the - condenser and evaporator and provides the pressure 
drop between the high side and low side of the system. 
Add refr...
Preview 2 out of 6 pages
Add to cartA metering device provides a small opening, or orifice, through - which only a certain amount of 
refrigerant flows into the evaporator. 
A metering orifice is installed between the - condenser and evaporator and provides the pressure 
drop between the high side and low side of the system. 
Add refr...
Does sensible hat gain cause the temp in the house to increase? - Yes 
Htms are calculated how? - Multiplying the U-value times the temperature difference 
In Manual J, what refers to anything that light can pass through, including windows, skylights, and glass 
doors? - Feneatration 
Infiltration c...
Preview 1 out of 2 pages
Add to cartDoes sensible hat gain cause the temp in the house to increase? - Yes 
Htms are calculated how? - Multiplying the U-value times the temperature difference 
In Manual J, what refers to anything that light can pass through, including windows, skylights, and glass 
doors? - Feneatration 
Infiltration c...
connection diagram - located on the outside of the unit on the service panel 
current is known as - amperage 
current refers to - the flow of electrons through a conductor 
How many watts will an electric heater draw if the measured voltage is 250 volts, drawing 20 amps - 
5000 watts 
how much curre...
Preview 1 out of 3 pages
Add to cartconnection diagram - located on the outside of the unit on the service panel 
current is known as - amperage 
current refers to - the flow of electrons through a conductor 
How many watts will an electric heater draw if the measured voltage is 250 volts, drawing 20 amps - 
5000 watts 
how much curre...
1 hp = - Answer-746 watts 
100 milliamps= - Answer-0.1 amps 
2.1KV= - Answer-2100V 
3 resistors are wired in series. Each is 300 ohms. What is the total resistance? - Answer-900 ohms 
A 240V 3 wire circuit can be split into two 120V circuits - Answer-True 
a black colored wire usually indicates - An...
Preview 2 out of 5 pages
Add to cart1 hp = - Answer-746 watts 
100 milliamps= - Answer-0.1 amps 
2.1KV= - Answer-2100V 
3 resistors are wired in series. Each is 300 ohms. What is the total resistance? - Answer-900 ohms 
A 240V 3 wire circuit can be split into two 120V circuits - Answer-True 
a black colored wire usually indicates - An...
A grain is a small measurement of weight that is used to measure water vapor in the air. How many 
grains are equal to one pound? - 7,000 
Area measurements are used to measure: - The size of a floor in a room. 
For which of the following measurements is area used? - Surfaces 
How many grains are in...
Preview 1 out of 3 pages
Add to cartA grain is a small measurement of weight that is used to measure water vapor in the air. How many 
grains are equal to one pound? - 7,000 
Area measurements are used to measure: - The size of a floor in a room. 
For which of the following measurements is area used? - Surfaces 
How many grains are in...
____________________ means that a particular circuit or component has a complete path for current to 
follow. - AnswerContinuity 
A conductor is a material that does not take on electrons. - AnswerFalse 
A high pressure switch will most likely be located where in the refrigeration system? - AnswerDi...
Preview 2 out of 14 pages
Add to cart____________________ means that a particular circuit or component has a complete path for current to 
follow. - AnswerContinuity 
A conductor is a material that does not take on electrons. - AnswerFalse 
A high pressure switch will most likely be located where in the refrigeration system? - AnswerDi...
A restriction in the liquid line after the receiver(or condenser) will cause low or high subcool? - 
Normal actually since refrigerant not used in the evaporator is stored in the receiver. 
A restriction in the liquid line after the receiver(or condenser), the condensing temperature will be... - 
Lo...
Preview 2 out of 11 pages
Add to cartA restriction in the liquid line after the receiver(or condenser) will cause low or high subcool? - 
Normal actually since refrigerant not used in the evaporator is stored in the receiver. 
A restriction in the liquid line after the receiver(or condenser), the condensing temperature will be... - 
Lo...
A properly placed ladder should have film footing, and the top of the ladder should be - At least 
three feet above the roof 
A refrigerant container should never be heated or stored in temperatures above: - 125°F. 
A simple tool that technicians can use to check for energized circuits is a: - Nonc...
Preview 2 out of 7 pages
Add to cartA properly placed ladder should have film footing, and the top of the ladder should be - At least 
three feet above the roof 
A refrigerant container should never be heated or stored in temperatures above: - 125°F. 
A simple tool that technicians can use to check for energized circuits is a: - Nonc...
All NATE specialties are offered at two levels. They are: - Installation and Service 
Codes are different than industry standards because codes are - Required by Law 
Customers often judge the ability of an HVACR technician by - His Apperance, Neatness of vehicle, 
cleanliness of work equipment (All...
Preview 1 out of 3 pages
Add to cartAll NATE specialties are offered at two levels. They are: - Installation and Service 
Codes are different than industry standards because codes are - Required by Law 
Customers often judge the ability of an HVACR technician by - His Apperance, Neatness of vehicle, 
cleanliness of work equipment (All...
14.7 psia (pounds per square inch absolute) is _________. - Approximately 0 PSIG 
A 30 pound cylinder of reclaimed R-410A refrigerant has been stored over night at 70°F. What should be 
the approximate pressure in the cylinder? - 201 Psig 
A compound pressure gauge connects ___________. - to the lo...
Preview 1 out of 4 pages
Add to cart14.7 psia (pounds per square inch absolute) is _________. - Approximately 0 PSIG 
A 30 pound cylinder of reclaimed R-410A refrigerant has been stored over night at 70°F. What should be 
the approximate pressure in the cylinder? - 201 Psig 
A compound pressure gauge connects ___________. - to the lo...
A common rating that's used to specify the capacity of refrigeration equipment is the _______, which is 
equal to 12,000 BTU per hour - Ton 
A gas has a weight of 5 pounds and a volume of 100 cubic feet. What is the specific volume of this gas? - 
20 
A gauge pressure of 30 psig is equivalent to an...
Preview 1 out of 3 pages
Add to cartA common rating that's used to specify the capacity of refrigeration equipment is the _______, which is 
equal to 12,000 BTU per hour - Ton 
A gas has a weight of 5 pounds and a volume of 100 cubic feet. What is the specific volume of this gas? - 
20 
A gauge pressure of 30 psig is equivalent to an...
How do electronic leak detectors work? - They search for a leak in an enclosed space, some may 
also sense the refrigerant in the air. 
How do you take the temperature of a refrigerant line? - Using the thermocouple assure it is 
tightly pressed against the line, and insulated since they are very se...
Preview 1 out of 2 pages
Add to cartHow do electronic leak detectors work? - They search for a leak in an enclosed space, some may 
also sense the refrigerant in the air. 
How do you take the temperature of a refrigerant line? - Using the thermocouple assure it is 
tightly pressed against the line, and insulated since they are very se...
(I) represents in equation - "intensity" 
12-gauge (AWG)= 20 amps is recommended for - residential receptacle outlets. 
14-gauge (AWG)= 15 amps wire be suitable for - lighting circuits. 
a breaker rated for 15 amps is installed into a 30 amp circuit - not enough current to flow 
a breaker that is ...
Preview 2 out of 8 pages
Add to cart(I) represents in equation - "intensity" 
12-gauge (AWG)= 20 amps is recommended for - residential receptacle outlets. 
14-gauge (AWG)= 15 amps wire be suitable for - lighting circuits. 
a breaker rated for 15 amps is installed into a 30 amp circuit - not enough current to flow 
a breaker that is ...
A solution used as a secondary refrigerant in chillers consisting of water and a chemical which lowers the 
water's freezing point is called: - Brine. 
Air-conditioning tube-and-fin coils are commonly available as: - Slab coils, slant coils, "A" coils, and 
"N" coils. 
An evaporator in which re...
Preview 2 out of 6 pages
Add to cartA solution used as a secondary refrigerant in chillers consisting of water and a chemical which lowers the 
water's freezing point is called: - Brine. 
Air-conditioning tube-and-fin coils are commonly available as: - Slab coils, slant coils, "A" coils, and 
"N" coils. 
An evaporator in which re...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller PatrickKaylian. Stuvia facilitates payment to the seller.
No, you only buy these notes for $18.09. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
67096 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now