Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

National Home Inspector Exam (NHIE) Whole House Practice Questions and Answers Already Passed

Rating
-
Sold
-
Pages
12
Grade
A+
Uploaded on
07-09-2022
Written in
2022/2023

tional Home Inspector Exam (NHIE) Whole House Practice Questions and Answers Already Passed During an inspection of a gas dryer, you observe no exhaust vent. Your report should: A. Recommend installing a metal dryer duct vented to the exterior. B. Recommend installing a flexible plastic dryer duct vented to the exterior. C. Indicate a code violation and state that corrective action should be taken. D. Indicate that this is not a problem. A) Recommend installing a metal dryer duct vented to the exterior. A collar tie is found in: A. the attic near the top plate B. the basement between floor joists C. a wall at the intersection of two walls D. the upper third of the rafter length D. the upper third of the rafter length A claims made, errors and omissions insurance policy includes claims filed A. during the time the policy is in effect. B. after the policy has elapsed. C. prior to the effective date. D. while the inspector maintains any required licensing. A. during the time the policy is in effect. On a previous work day, you left the cover off of the access to the crawl space. A person fell the next day and was injured. Which of the following insurance types will be used to pay damages? A. Bonding. B. General liability C. Errors and omissions and broker liability D. Claims made and occurrence B. General liability A home inspection agreement is most likely to be interpreted using which law? A. Federal B. State C. County D. Parish B. State While inspecting a heat pump in the cooling mode, you measure a 28 degree F differential between the interior supply and return air. When the ambient outdoor conditions are 92 degrees and 50% humidity, you should suspect A. the outdoor fan running too slowly. B. an over heating compressor. C. a dirty air handler filter. D. thermostat set too low. C. a dirty air handler filter. When measuring the temperature differential between supply air and return air in a central air conditioning system, on a humid summer day the difference should be A. 5 degree F and 15 degrees F. B. 15 degree F and 20 degrees F. C. 20 degree F and 30 degrees F. D. 30 degree F and 45 degrees F. B. 15 degree F and 20 degrees F. While inspecting a metal framed building, you observe non-metallic sheathed wire installed through standard cut-outs. Your report will suggest A. plastic grommets should be installed. B. the wire must be removed and replaced with bx cable. C. all the wiring must be re-run in rigid conduit from the ceiling. D. all the wiring must be re-run in rigid conduit from the floor. A. plastic grommets should be installed. The ampacity of copper-clad aluminum is A. the same as for copper wiring. B. higher than for copper wiring. C. the same as for aluminum wiring. D. lower than for aluminum wiring. C. the same as for aluminum wiring. Which of the following is currently required to be GFCI protected? A. Hydromassage tub B. Attic receptacles C. Bedroom receptacles D. receptacles in finished basement A. Hydromassage tub In new construction, the MINIMUM overhead electrical conductor clearances are A. walkway: 8 feet, roadway: 16 feet, deck: 12 feet B. walkway: 9 feet, roadway: 15 feet, deck: 10 feet C. walkway: 10 feet, roadway: 18 feet, deck: 10 feet D. walkway: 12 feet, roadway: 20 feet, deck: 12 feet C. walkway: 10 feet, roadway: 18 feet, deck: 10 feet A GFCI functions by sensing A. an overcurrent condition. B. a current imbalance. C. a short circuit. D. an open neutral. B. a current imbalance. Looking into an open electric service panel you see a wire with charred insulation. What should you do? A. You are not responsible for removing electric service panel so this situation will never occur. B. Check the wire to see if it is hot and then tighten any loose connections. C. Disconnect the wire, cut the burned area off, and strip and reconnect the wire. D. Report on the condition, and inform the homeowner that an electrician should repair. D. Report on the condition, and inform the homeowner that an electrician should repair. Which type overcurrent devices are not allowed in new construction? A. Edison base fuses B. Cartridge fuses C. circuit breakers D. half size reakers A. Edison base fuses Reversed polarity in a receptacle means: A. the receptacle is installed upside down. B. the hot and neutral conductors are reversed C. the hot and equipment-grounding conductors are reversed D. the hot and equipment-grounding conductors are reversed B. the hot and neutral conductors are reversed Ivy

Show more Read less
Institution
National Home Inspector
Course
National Home Inspector









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
National Home Inspector
Course
National Home Inspector

Document information

Uploaded on
September 7, 2022
Number of pages
12
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

  • a collar tie is foun
$9.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Thumbnail
Package deal
National Home Inspector Bundled Exams Questions and Answers All Rated A
-
20 2022
$ 20.99 More info

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
BrilliantScores Chamberlain College Of Nursng
View profile
Follow You need to be logged in order to follow users or courses
Sold
2879
Member since
4 year
Number of followers
2237
Documents
16205
Last sold
1 day ago
latest updated documents, correct, verified & graded A study materials

get bundles, documents, test banks, case studies, shadow health's, ATIs, HESIs, study guides, summary, assignments & every kind of study materials.

3.8

782 reviews

5
391
4
118
3
118
2
38
1
117

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions