Journeyman Electrician Exam Questions and Answers 2023 Graded A+ For other than one-and two-family dwellings, when building a new electrical service, at least one (1) 125-volt, single-phase, 15- or 20-ampere-rated receptacle outlet shall be located within at LEAST _____ of the electrical service...

[Show more]

Preview 2 out of 12  pages

  • February 15, 2023
  • 12
  • 2022/2023
  • Exam (elaborations)
  • Questions & answers
  • Journeyman Electrician
  • Journeyman Electrician
avatar-seller
Parie
Journeyman Electrician Exam Questions and Answers 2023 Graded A + For other than one -and two -family dwellings, when building a new electrical service, at least one (1) 125 -volt, single -phase, 15 - or 20 -ampere -rated receptacle outlet sha ll be located within at LEAST _____ of the electrical service equipment? -ANS>> 50 feet The ampacity of a conductor is defined by the NEC to be the maximum current, in amperes, a conductor can carry continuously under the conditions of use without exceed ing ______? -
ANS>> it's temperature rating Disconnect switch enclosure installed in a Class II, Division 2 location shall be listed as _____? -
ANS>> dusttight The interior of enclosures or raceways installed underground shall be considered as a _____ location? -ANS>> dry Determine the MAXIMUM allowable current -carrying capacity of four (4) size 1/0 AWG THW copper current -carrying conductors installed in a common raceway with an ambient temperature of 86 degrees F? -ANS>> 120 amperes The NEC defines a continuous load to be a load where the maximum current on the circuit is expected to continue for at LEAST____ hours or more? -ANS>> three The service disconnecting means for each electrical service shall consist of NOT more than _____ switches or circuit breakers, mounted in a single enclosure or in a group of separate enclosures. -ANS>> six Given: You have determined a conductor has a computed allowable ampacity of 75 amperes. What is the MAXIMUM standard ampere rating of the overcur rent protection device the NEC® permits to protect this circuit where this is not a motor circuit or part of a multioutlet branch circuit supplying more than one receptacle? -ANS>> 80 amperes A 208 -volt, 3 -phase, 50 hp, squirrel -cage, continuous -duty, ac motor has a full -load running current rating of _____? -ANS>> 143 amperes What is the MAXIMUM distance that a disconnect switch is permitted to be located from the operator's station for a portable carnival ride? -ANS>> 6 feet Determine the MINIMUM tr ade size electrical metallic tubing (EMT) required to enclose eight (8) size 6 AWG copper conductors with THHW insulation, when installed in a 50 foot conduit run? -ANS>> 1 1/4 in. Where exceptions are not applicable, when a feeder supplies a continuous load of 240 amperes, the overcurrent protection device protecting this circuit shall have a rating of at LEAST _____? -ANS>> 300 amperes Liquidtight flexible metal conduit (LFMC) shall be securely fastened WITHIN _____ of each box or other conduit termin ation? -ANS>> 12 inches Where a pull box to be installed will contain conductors of size 4 AWG and larger, and a straight pull of the conductors is to be made, the length of the box shall NOT be less than ____times the trade diameter of the largest condu it entering the box. -ANS>> eight Conduit nipples not over 24 inches in length may be filled to a MAXIMUM of _____ of their cross -sectional area. -ANS>> 60 percent Determine the MAXIMUM number of size 14 AWG THHN conductors permitted to be installed in a trade size 3/8 in. flexible metal conduit (FMC) that contains a bare size 14 AWG grounding conductor, when the FMC has external fittings. -ANS>> four Which one of the following listed conduits does the NEC® permit to enclose conductors supplying wet -niche underwater pool luminaires? -ANS>> Schedule 40 rigid polyvinyl chloride conduit (PVC)

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Parie. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $9.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

62890 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$9.99  2x  sold
  • (0)
  Add to cart