100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
Previously searched by you
EPA 608 CERTIFICATION EXAM LATEST ACTUAL EXAM ALL 210 REAL EXAM QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES (VERIFIED ANSWERS) |ALREADY GRADED A+$19.49
Add to cart
EPA 608 CERTIFICATION EXAM LATEST ACTUAL EXAM ALL 210 REAL EXAM QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES (VERIFIED ANSWERS) |ALREADY GRADED A+
6 views 0 purchase
Course
EPA 608 CERTIFICATION
Institution
EPA 608 CERTIFICATION
EPA 608 CERTIFICATION EXAM LATEST ACTUAL
EXAM ALL 210 REAL EXAM QUESTIONS AND CORRECT
DETAILED ANSWERS WITH RATIONALES (VERIFIED ANSWERS)
|ALREADY GRADED A+
EPA 608 CERTIFICATION EXAM LATEST ACTUAL
EXAM ALL 210 REAL EXAM QUESTIONS AND CORRECT
DETAILED ANSWERS WITH RATIONALES (VERIFIED ...
EPA 608 CERTIFICATION EXAM LATEST 2023-2024 ACTUAL
EXAM ALL 210 REAL EXAM QUESTIONS AND CORRECT
DETAILED ANSWERS WITH RATIONALES (VERIFIED ANSWERS)
|ALREADY GRADED A+
The EPA considers a major repair to be the replacement of what
4 items? - ANSWER-
1.Evaporator2.Condenser3.Compressor4.Auxillary Heat
Exchanger
When the refrigerant is put back into a Type III chiller, following
recovery and system repair, where is it added? - ANSWER-The
charging valve on the evaporator.
What method is used to find suspected water tube leaks in
chillers? - ANSWER-Hydrostatic (tube) test
What temperature should be attained when removing oil from a
low pressure system to ensure a lower level of refrigerants in the
oil? - ANSWER-130-Degrees F
The typical design burst pressure for a rupture disc is what? -
ANSWER-15 PSIG
Excessive moisture collection in the purge unit can indicate what?
- ANSWER-Tube Leakage
, EPA 608 CERTIFICATION EXAM LATEST 2023-2024 ACTUAL
EXAM ALL 210 REAL EXAM QUESTIONS AND CORRECT
DETAILED ANSWERS WITH RATIONALES (VERIFIED ANSWERS)
|ALREADY GRADED A+
Vacuum pumps need to be capable of pulling what level of
vacuum? - ANSWER-500 microns
All refrigeration systems containing more than 50 lbs. of
refrigerant must be repaired when the annual leak rate
exceeds___? - ANSWER-35%
The most efficient method of leak checking a charged low-
pressure system is to use? - ANSWER-Controlled hot water or
heater blankets.
Systems with open drive compressors are prone to leak where? -
ANSWER-At the shaft seal.
What does ASHRAE standard 15 require? - ANSWER-A
refrigerant monitor that will sound and alarm and automatically
start a ventilation system in equipment rooms before the
refrigerant concentration reaches the TLV-TWA.
TLV-TWA - ANSWER-Threshold Limit Values - Time Weighted
Average: The TWA concentration for a conventional 8-hour
workday and a 40-hour workweek, to which it is believed that
nearly all workers may be repeatedly exposed, day after day, for a
working lifetime without adverse health effect.
, EPA 608 CERTIFICATION EXAM LATEST 2023-2024 ACTUAL
EXAM ALL 210 REAL EXAM QUESTIONS AND CORRECT
DETAILED ANSWERS WITH RATIONALES (VERIFIED ANSWERS)
|ALREADY GRADED A+
A-1 Group Refrigerants only require what? - ANSWER-Oxygen
Deprivation Sensor
What are Cooling Towers? - ANSWER-They are heat removal
devices used to transfer process waste heat to the atmosphere.
Threshold Limit Values - Time Weighted Average: The TWA
concentration for a conventional 8-hour workday and a 40-hour
workweek, to which it is believed that nearly all workers may be
repeatedly exposed, day after day, for a working lifetime without
adverse health effect.
Oxygen Deprivation Sensor
Refrigerant Specific" Mechanical Room Sensor.
What is the maximum test pressure to use for pressurizing Type
III centrifugal systems with nitrogen? - ANSWER-10 psig
, EPA 608 CERTIFICATION EXAM LATEST 2023-2024 ACTUAL
EXAM ALL 210 REAL EXAM QUESTIONS AND CORRECT
DETAILED ANSWERS WITH RATIONALES (VERIFIED ANSWERS)
|ALREADY GRADED A+
Enough vapor has entered the system and you may begin
charging liquid refrigerant when the refrigerant saturation
temperature increases to? - ANSWER-36F
the method to charge a system that has a normal charge of 80
pounds is to charge with? - ANSWER-charge with liquid through
the liquid line service valve
after installation of a field piped r-410a split heat pump, the unit
should be first tested: - ANSWER-pressurized by nitrogen and
then leak checked
pressure relief valves shall not be installed - ANSWER-in a series
When charging an R-12 refrigeration system that uses a water
cooled condensor, you must first charge with vapor to a pressure
of at least _____ , before switching to a liquid charging. -
ANSWER-35PSIG
The component directly following the evaporator of the
refrigeration system is the - ANSWER-accumulator
a reciprocating compressor should not be recognized the -
ANSWER-discharge service valve is closed
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller erickarimi. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $19.49. You're not tied to anything after your purchase.