Sprinkler Chart Questions (S12) Graded A+
How often shall the stem of an OS&Y Valve be lubricated - Answer-Annually The 3 year dry pipe trip test is to be performed by whom? - Answer-MP & MFSPC Fire department connections are to be inspected how often? - Answer-Quarterly Water motor gongs are to be tested how often? - Answer-Quarterly In a water spray fixed system inspection if the strainer is found corroded what color tag is required? - Answer-Yellow A sprinkler head with a red frame has a temperature classification of? - Answer-Extra High (325 - 375°F) The Hydraulic name plate shall be inspected how often? - Answer-Quarterly What color tag is required when sprinkler heads are found to be lightly corroded? - Answer-Orange Obstructions in sprinkler systems shall be investigated how often? - Answer-5 Years What color tag is required when the circuit breakers on a special service pump are over 2 years old? - Answer-Orange What color tag is required when sprinkler heads made prior to 1920 have not been replaced? - Answer-Orange, notify FDNY after 30 days During an operational test of a foam water sprinkler system, if the nozzles are plugged what color tag is used? - Answer-Red Steel water storage tanks without corrosive protection are to be inspected how often? - Answer-3 yearsA sprinkler head with a white frame has a temperature rating of? - Answer-175 - 225°F The weekly test of an electric fire pump is how long? - Answer-10 minutes The weekly test of a Diesel fire pump is how long? - Answer-30 minutes Upon inspection of a sprinkler system, if the hydraulic nameplate is missing what color tag is used? - Answer-Yellow When inspecting a preaction system, if the electrical components are not in service what color tag is used? - Answer-Red Vane type water flow devices shall be tested how often? - Answer-Semi-annually Proper number of spare heads and wrenches shall be inspected how often? - Answer-Annually The temperature rating of a sprinkler head with a green glass bulb is? - Answer-175 - 225°F When inspecting a sprinkler system if the spare sprinkler cabinet is missing what color tag should be used? - Answer-Yellow On a dry pipe sprinkler head if no tests were conducted in 12 years what color tag should be used? - Answer-Orange Red Tag - Answer-Impairment (Notify FDNY, shall be fixed immediately) Orange Tag - Answer-Critical Deficiency (Notify FDNY if not fixed after 30 days) Yellow Tag - Answer-Non-critical Deficiency (Notify FNDY if not fixed after 30 days) Green Tag - Answer-System fully operational without defectsOrange/Red bulb temperature - Answer-135 - 170°F Yellow or Green Bulb temperature - Answer-175 - 225°F Blue Bulb temperature - Answer-250 - 300°F
Written for
- Institution
- Sprinkler
- Course
- Sprinkler
Document information
- Uploaded on
- March 14, 2024
- Number of pages
- 11
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers