NCCER ELECTRICAL LEVEL 1 MODULE 11- RESIDENTAL WIRING The minimum number of small appliance circuits required by the NEC® in a kitchen area is _____. ** 2 When sizing residential electrical services, the laundry load is calculated as _____. 1,500VA When sizing the general lighting load for electric services, the first 3,000VA is rated at _____. ** 100% According to NEC Section 220.53, a demand factor of 75% may be applied to four or more _____. Fixed appliance loads The minimum service disconnect rating for a one-family dwelling is _____. 100A The general lighting load in a residence is 3,600VA at 120V. What is the amperage? 30A