NETA ETT Certified Level 3 Complete Test Questions 2024. A newly installed 4160V emergency generator has an insulation resistance value of 150 Megohms after one minute with an equipment temperature of 32 degrees C. Is this value acceptable per NETA standards? No NETA ATS-2017 Table 100.11 ...

[Show more]

Preview 4 out of 96  pages

  • March 29, 2024
  • 96
  • 2023/2024
  • Exam (elaborations)
  • Questions & answers
  • NETA.
  • NETA.
avatar-seller
ROSEGRADES
NETA ETT Certified Level 3
A newly installed 4160V emergency generator has an insulation resistance value of 150 Megohms after one minute with an equipment temperature of 32 degrees C. Is this value acceptable per NETA standards?
No
NETA ATS-2017 Table 100.11
https://testguy.net/content/240-Insulation-Resistance-Test-Values
Know the NETA-ATS Insulation Resistance tables
Which test method measures Hydrolyzable Flouride content in SF6 gas?
ASTM D2284
[Standard Test Method for Acidity of Sulfur Hexafluoride]
NETA ATS-2017 Table 100.13
Know the ASTM test names what what they test Brainpower
Read More
Previous
Play
Next
Rewind 10 seconds
Move forward 10 seconds
Unmute
0:01
/
0:15
Full screen
The operating speed of a protective relay is dependent on:
* Spring Tension
* Armature core air gap
* Rate of flux built up
https://en.wikipedia.org/wiki/
Protective_relay#Types_according_to_construction
This was originally a 'not question'. This list is not necessarily conclusive. It's simply the 'incorrect' answers to the 'not question'. According to IEEE C57.106, which test is recommended for routine acceptance of new, unprocessed oil from a supplier for use in circuit breakers?
ASTM D877
[Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes]
https://hvtechnologies.com/which-oil-testing-standard-should-you-choose-to-
determine-dielectric-breakdown-voltage/
Know IEEE C57 information. Know ASTM tests and definitions
Meter Sockets and meter disconnect switches should generally be connected on what side of a service disconnecting means?
The line side
NFPA 70-2017 Article 230.82(3)
https://www.electricallicenserenewal.com/Electrical-Continuing-Education-
Courses/NEC-Content.php?sectionID=40.0
This was originally a True/False statement question. The answer stated that the load side is wrong. The reference above seems to imply that meter sockets and meter disconnect switches should generally be connected on the line side.
Know NFPA 70
What size neutral resistor would be required to limit the fault current of a 13,800-480Y/277V 1500kVA Transformer to 5A?
55.4
Know Ohm's Law. 277 V / 5A = 55.4 ohms
I believe that since this is dealing with the neutral, Line-Neutral voltage (277 V) should be used in the formula. 5 A on the line will also be 5A on the windings since the transformer configuration is a Wye configuration. I also believe that the impedance of the transformer is negligible in this calculation since it isn't mentioned in the question and presumably would only limit the fault current further.
Correcting the power factor of three-phase loads normally involves adding (capacitance, inductance) in (series, parallel)
capacitance in parallel
http://archive.is/WOiLd

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller ROSEGRADES. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $13.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

73918 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$13.99  5x  sold
  • (0)
  Add to cart