100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Maine Fuel Code - Journeyman Exam Practice Test With Complete Solutions $13.99   Add to cart

Exam (elaborations)

Maine Fuel Code - Journeyman Exam Practice Test With Complete Solutions

 8 views  0 purchase
  • Course
  • Institution

Maine Fuel Code - Journeyman Exam Practice Test With Complete Solutions

Preview 2 out of 5  pages

  • May 10, 2024
  • 5
  • 2023/2024
  • Exam (elaborations)
  • Questions & answers
avatar-seller
Maine Fuel Code - Journeyman Exam Practice
Complete Solutions ✔✔
How many apprentices can a journeyman directly supervise? - ANS>2 apprentices - MFC 3.2.6


Can a licensed Journeyman perform a cleaning on a wood/oil combination unit without direct supervision? -
apprentice solid fuel license MFC 3.2.7


A graduate of an 160 hour Maine fuel board approved course on oil burning equipment may set for the journ
ANS>Upon successful completion of the requisite education, prior to completing the apprenticeship


The Maine fuel board adopts NFPA 31 and NFPA 211, which edition? - ANS>NFPA 31 2011 edition and NFPA
6.1.2 and 6.1.13


What are the two chapters and sections of NFPA 31 that Maine does not adopt? - ANS>Chapter 7 section 7.1
7.3.1 MFC 6.2.1


What does Maine fuel board say about inspecting chimneys as required by NFPA 211 chapter 14?` - ANS>The
not adopt chapter 14 of NFPA 211. MFC 6.2.6.4.3


All work must be conducted, installed and completed in a ______? - ANS>Neat and professional manner refl
of workmanship. MFC 8.2


When performing any service work on a customer's heating system, the licensee must notify the homeowne
violations and make recommendations to address them. MFC 8.4.2


When performing an annual tune-up on a heating system a combustion efficiency test must be? - ANS>Cond
results must be posted on site. MFC 8.4.3


When installing a furnace, direct fired water heater or boiler what must be done prior to placing it in service
installation must be brought into compliance with the requirements of NFPA 31 and all other rules of the Ma
8.5.1


When installing a new oil burner the ____ must be brought into compliance with the rules of the board befo
ANS>Wiring; the unit is fired. MFC 8.5.2

, Prior to a boiler replacement a ____ or a _____ must be conducted before replacement of an existing system
load calculation. MFC 8.5.5.2


Who must maintain a copy of a heat load calculation? - ANS>The licensee. MFC 8.5.5.2


The low water cutoff must be located where? - ANS>At a level recommended by the manufacturer, but in no
cutoff be installed below the crown sheet. MFC 8.6.2


Boiler and safety control or devices may have no ______ installed between the _____ and the ______. - ANS
devices; boiler and safety device/control. MFC 8.6.4


When outside tanks are used a _____ must be installed where the supply line enters (inside) the building - A
shutoff valve. MFC 8.7.1.1.1


When inside tanks are installed in a separate room the thermally operated valve must be________? - ANS>In
enters the room where the appliance is located. MFC 8.7.1.1.2


A check valve may be installed in the supply line but no _____ or _____ may be installed in the return line co
pump. - ANS>Valve or obstruction. MFC 8.7.1.2


What must be done if a thermally operated valve larger than 1/2" must be used? - ANS>Obtain written appr
prior to installation. MFC 8.7.2


An oil supply or return line under cement, sub-floor or earth surface must be _____ and without _____? - AN
any splices MFC 8.8.1


All copper oil supply and return lines must be encased in a _____ such as PVC ENT or be _____ or other appr
be _____? - ANS>Continuous piece of non-metallic liquid tight conduit; coated coper tubing; secured in orde
damage. MFC 8.8.2


The end of the conduit for an oil supply or return line shall not exceed _____ from any fitting, except the con
and at the pump located at the burner shall not exceed _____? - ANS>2 inches ; 6 inches MFC 8.8.2


In order to avoid undetected oil leaks under floors the conduit must be _____ than the supply and return lin
conduit must penetrate the cement or earth surface a minimum of _____? - ANS>One pipe size larger; 2 inch

8.8.2

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Schoolflix. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $13.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

80796 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling

Recently viewed by you


$13.99
  • (0)
  Add to cart