100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
IRC TEST QUESTIONS COMPLETE WITH A+ GRADED ANSWERS $14.49   Add to cart

Exam (elaborations)

IRC TEST QUESTIONS COMPLETE WITH A+ GRADED ANSWERS

 2 views  0 purchase
  • Course
  • Institution

IRC TEST QUESTIONS COMPLETE WITH A+ GRADED ANSWERS The International Residential Code is applicable to single-family dwellings a maximum of _______________ stories in above-grade-plane height. A. One B. Two C. Three D. Four C If there is a conflict in the code between a general requirem...

[Show more]

Preview 4 out of 41  pages

  • May 13, 2024
  • 41
  • 2023/2024
  • Exam (elaborations)
  • Questions & answers
avatar-seller
IRC Plumbing Practice Test|Complete Questions with
A+ Graded Answers
What is the minimum size of a water meter and service piping in inches for a water supply system of
34 fixture units with a maximum developed length of 200 feet. The water pressure of the system is 35
psi.
1

Table AP201.1


What is the minimum sized trap that can be used for the drainage system of a bathtub (with or
without shower head and/or whirlpool attachments)?
1.5

Table P3201.7


A water heater pan drain must extend full-size and terminate over a suitably located indirect waste
receptor or must extend to the exterior of the building and terminate not less than _____ inches and
not more than _____ inches above the adjacent ground surface.
6, 24

P2801.6.2


A laundry tray waste line is permitted to connect into a standpipe for automatic clothes washer drain.
The standpipe must extend not less than _____ above the trap weir and must extend above the flood
level rim of the laundry tray.
30 inches (762 mm)

P2706.1.2.1


Clothes closets, linen closets and pantries not exceeding _____ in area, with the smallest dimension
not greater than 3 feet (915 mm) and having wall and ceiling surfaces of gypsum board will not
require fire sprinklers.
24 square feet (2.2 m2)

P2904.1.1


If a water closet can be removed to provide cleanout access, does that fulfill the cleanout
requirement of the code?
No

P3005.2.3


Appliances and equipment used for heating water or storing hot water have to be protected by
_____.
pressure-relief valve and temperature-relief valve or a combination pressure and temperature-relief
valve.

P2804.1

,Where the fixture drains connect at different levels, the common vent must connect as a _____
extension of the _____ drain.
vertical, vertical

P3107.3


The minimum air gap distance in inches for lavatories and other fixtures with effective opening not
greater than 1/2 inch in diameter that are close to a wall is:
1.5

Table P2902.3.1


In areas prone to flooding as established by the code, water supply systems must be designed and
constructed to prevent _____ of floodwaters.
infiltration

P2602.2


When either a public water-supply or sewer system, or both, are not available, _____, an individual
water-supply or individual sewage-disposal system, or both, must be provided.
or connection thereto is not feasible

P2602.1


_____ installed in a bathroom are not required to be installed within an enclosure.
direct-vent water heaters

M2005.2


For water supply systems used predominantly for flush tanks having a water supply fixture unit load
of 12, what is the comparable demand in gallons per minute.
16.0

Table P2903.6(1)


Test equipment, materials and labor must be furnished by the ______
permittee

P2503.3


The minimum size in inches of a combination waste and vent pipe connecting to a building drain or
building sub drain and serving 31 d.f.u. is _____.
3

Table 3111.3


The outlet of a water heaters pressure relief valve, temperature relief valve or combination valve,
must be directly connected to the _____.

,none of the above

P2804.6.1


What is the minimum pipe support spacing in feet, required for copper or copper alloy tubing (1 1/4
inch diameter and smaller_ installed in a horizontal orientation.
6

Table P2605.1


The flow velocity of the water distribution system must be controlled to reduce the possibility of
_____.
water hammer

P2903.5


A wet 2 inch vent can handle venting for _____ fixture unit loads.
4

Table P3108.3


There must be at least _____ inches clearance in front of the water closet, bidet or lavatory to any
wall, fixture or door.
21

P2705.1


Open hub waste receptors must be permitted in the form of a hub or pipe extending not less than
_____ inch(es) above a water impervious floor, and are not required to have a strainer.
1

P2706.1


The minimum air gap distance in inches for sink, laundry trays, gooseneck back faucets and other
fixtures with effective openings not greater than 3/4 inch in diameter that are away from a wall is:
1.5

Table P2902.3.1


Where the drainage piping has been roughed-in for future fixtures, a rough-in connection for a vent
must be installed a minimum of _____.
one-half times the diameter of the drain

P3104.6


Grinder pumps or grinder ejectors that receive the discharge of water closets must have a minimum
discharge opening of _____.
1 1/4 inches (32 mm)

, P3007.6


The minimum air gap distance in inches for over-rim bath fillers and other fixtures with effective
openings not greater than 1 inch in diameter that are away from a wall is:
2

Table P2902.3.1


What is the minimum size of a water meter and service piping in inches for a water supply system of
21 fixture units with a maximum developed length of 500 feet. The water pressure of the system is 48
psi.
1.5

Table AP 201.1


A _____ strainer or basket must cover the waste outlet of waste receptors.
removable

P2706.1


Joints in plastic piping must be made with approved fittings by ______.
1. solvent cementing; or
2. heat fusion; or
3. corrosion-resistant metal clamps with insert fittings or compression connections

P2906.9


For a fire sprinkler system the service line is a 3/4" pipe 78 feet in length. The required flow rate at
the sprinklers is 12 gpm. Determine the pressure loss in pound per square inch (psi), in the water
service pipe based on the selected size of the water service.
24.9

Table P2904.6.2(1)


Joints and connections in the plumbing system must be ______ for the intended use or required test
pressure.
gas tight and water tight

P2906.8


What is the minimum size of distribution piping in inches for a water supply system of 80 fixture units
with a maximum developed length of 150 feet. The water pressure of the system is 70 psi.
1.25

Table AP201.1


A sink and dishwasher are permitted to discharge through a single _____ inch trap.
1.5

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller LectAziim. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $14.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

83637 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$14.49
  • (0)
  Add to cart